Downloads
Technical resources in relation to the listed system and equipment
Version History
This product represents a continuation of ActionPower’s solar array simulation platform.
- Previously: APS DC Power Supply – Solar Array Simulator
- Current: TITAN Series Solar Array Simulator (series renaming and model update)
Core photovoltaic simulation capabilities—including I–V curve emulation, dynamic irradiance response, and application coverage—remain continuous across the product line. CE-certified TITAN configurations are available for selected models to support compliant testing and validation in regulated markets.
CE-Certified Model Options
Find the right specification for your requirements
Non-CE-Certified Model Options
Find the right specification for your requirements
Highlighted Technical Advantages
Advanced high-power solar array simulator with flexible SAS mode, I-V curve simulation functions, and powerful programming capabilities.
Scalable Solar Array Simulation from Hundreds of kW to Multi-MW Systems
Covering power range spanning from component-level and string inverter validation to utility-scale central inverter and PCS testing, TITAN series is designed with modular power blocks ranging from 300kW to 750kW meanwhile available for parallel connection to deliver scalable output power up to 10 MW with inter-cabinet communication and dynamic specifications uncompromised thanks to ActionPower's advanced hardware technologies.
Users benefit from such a technically uncompromised upscalability to grow alongside evolving PV system ratings without complete hardware replacement. Flexible system setups and implementations are enabled for consistent test methodology across different power levels while preserving identical I–V emulation fidelity and dynamic performance.
High-Fidelity Dynamic I–V Curve Emulation for MPPT Validation
TITAN reproduces real-world photovoltaic array behavior through high-resolution I–V curve emulation with up to 4096 discrete points which is the market-leading resolution capability. Curve update and switching intervals as fast as 100 ms allow accurate reproduction of rapid irradiance transitions, partial shading events, and temperature-dependent operating shifts. Engineers can generate both standard-compliant and user-defined I-V curves for variant testing purposes.
Both static I–V curves for steady-state MPPT efficiency evaluation and dynamic I–V sequences for transient MPPT tracking analysis are supported, ensuring realistic validation of inverter control algorithms under practical operating conditions.

Static I-V Curve Sandia Profile

Static I-V Curve EN50530 Profile

Static MPPT Profile

Dynamic MPPT Profile

I-V Curve Programming Interface

Shading Simulation Interface
Standards-Ready PV Testing with Programmable Scenario Control
The built-in operation interfaces of TITAN are embedded with PV simulation models and test workflows support EN 50530 and Sandia SAS methodologies. Users do not have to rely on any external modeling tools for generating regulation-required testing patterns. In addition to predefined standards-based recipes, engineers can import, edit, and sequence custom I–V curves via CSV files or parameterized models using Voc, Isc, fill factor, and temperature coefficients.
Complex test scenario - including sequential fault injection, irradiance ramps, and extended cycling profiles - can be executed through programmable test recipes with up to 1,000 steps and 10,000-cycle operations.
Essential High Dynamic Performance for Transient and Stability Analysis
Optimized power stage design enables fast electrical response suitable for demanding dynamic tests:
- Voltage slew rate: up to 200 V/ms
- Load rise/fall time (10–90%): < 2.5 ms
- Current switching time (±90%): < 5 ms
- Low overshoot and undershoot during abrupt load transitions
Above-mentioned characteristics ensure stable and repeatable operating conditions during inverter startup, MPPT perturbation cycles, and control-loop stress testing, which are impractical if tested with real solar arrays whose output is rather uncontrollable and dynamic-lacking.

Current Rise Time (10% to 90%): 2.4 ms

Current Fall Time (90% to 10%): 2.4 ms

Current Switching Time (-90% to +90%): 4.8 ms

Current Switching Time (+90% to -90%): 4.8 ms

Voltage Overshoot During Sudden Load (500 V applied): 24 V

Voltage Undershoot During Sudden Load Removal (500 V removed): 22 V

Voltage Transition Time at 200 V/ms Rate (from 136 V to 536 V): 2.04 ms

Switching interval between 2 sets of I-V Curve is of only 100 ms
Regenerative Architecture for High-Power and Long-Duration Testing
TITAN is in nature a DC power supply with bidirectionality, benefiting from which feature, and if necessary, the bidirectional power flow is allowed to achieve efficient current sinking from the DUT during inverter operation. Regenerative operation returns up to 94% of absorbed energy back to the grid, consequently significantly reducing thermal stress, energy consumption, and operating cost in multi-hundred-kilowatt and megawatt-level PV testing environments.
Internal Resistance Emulation for Realistic Compromised Efficiency of PV Array
Temperature variations and uneven irradiation are inevitable with a real solar array system, which causes the power generation to be non-ideal. TITAN is programmable by internal resistance (Rint) emulation to replicate real-world PV source behavior under varying irradiance, weather, and temperature conditions.
By adjusting source impedance dynamically, engineers can evaluate MPPT robustness, control stability, and inverter response under realistic cable, array, and environmental effects beyond idealized I–V curves.
Precision Measurement and Deterministic Control
High-speed measurement and command refresh rates up to 1 kHz, combined with ±0.01% F.S. voltage and current accuracy, provide deterministic control and accurate data capture for ripple analysis, transient evaluation, and performance benchmarking across operating points.
Comprehensive Protection and Diagnostic Capabilities
Multi-layer protection mechanisms, including programmable OVP, OCP, OPP, and OTP to ensure safe operation for both the simulator and the device under test. Integrated fault logging records up to 200 events, with dedicated diagnostic queries supporting maintenance analysis, system integration, and long-term reliability tracking.
Specifications
The following specifications are subject to modifications and changes without notification in advance. All specifications measured are at product's maximum ratings, if not otherwise noted.
GENERAL SPECIFICATIONS
| Output Modes | Constant Voltage (CV), Constant Current (CC), Constant Power (CP), Programmable Output, and PV Standards (EN50530/Sandia) for Static and Dynamic MPPT Tracking and Solar Array Simulation |
|---|
| Energy Regeneration | Power sinking and regenerative feedback to grid |
|---|
| Electrical Isolation | Input/Output Electrical Isolation |
|---|
| Parallel Operation Capability | Multiple Units of the Same Model Can Be Paralleled |
|---|
DC OUTPUT
| VOLTAGE |
|---|
| Setting Resolution | 0.01 |
|---|
| Accuracy | ±0.1 F.S. |
|---|
| RMS Ripple | 0.1% F.S. (Resistive Load) |
|---|
| Voltage Swing Rate | 300V/ms |
|---|
| CURRENT |
|---|
| Setting Resolution | 0.01 |
|---|
| Accuracy | ±0.1 F.S. |
|---|
| RMS Ripple | 0.2% F.S. (Resistive Load) |
|---|
| Rise Time | 2.5ms (10%-90% @ rated current) |
|---|
| Switching Time | 5ms (between -90% and +90%) |
|---|
| I-V CURVE |
|---|
| Open Circuit Voltage (Voc) Setting Range | 20-1500V |
|---|
| Short Circuit Current (Isc) Setting Range | 1A-le |
|---|
| Simulated Fill Factor (FF) Range | 0.3-0.95 |
|---|
| PV Panel Type Selection | c-Si, Thin-film, Custom |
|---|
| I-V Curve Update Rate | Typical 100ms response time with online curve switching capability |
|---|
| I-V Curve Editing | EN50530, Sandia, simple custom curves; Static MPPT curves; Dynamic MPPT curves; Shading profiles |
|---|
| Points per Curve | 4096 |
|---|
| Curve Configuration | Custom I-V curve configuration via Voc, Isc, FF, Pm parametersBuilt-in I-V curve database with >100 preloaded curvesDynamic operation mode accounts for environmental factors (temperature, irradiance) with continuous output of environment-specific I-V curvesBuilt-in EN50530 dynamic I-V curve test procedure |
|---|
| UNIVERSAL PROGRAMMING FUNCTIONS |
|---|
| Programming Steps | 200 steps |
|---|
| Programming Parameters | Voltage/Current, Rise Time, Hold Time, Trigger Pulse Output |
|---|
| Rise Time Range | 1ms ~ 99999s |
|---|
| Flat Top Time Range | 1ms ~ 99999s |
|---|
| Minimum Programming Time Step | 1ms |
|---|
| Edit Mode | Add, Delete, Import, Export |
|---|
| Operation Mode | Run, Stop, Cycle |
|---|
| Trigger Mode | Auto, Manual, External |
|---|
MEASUREMENT SPECIFICATIONS
| Voltage Accuracy | ±0.1% F.S. |
|---|
| Voltage Resolution (V) | 0.001 |
|---|
| Current Accuracy | ±0.1% F.S. |
|---|
| Power Accuracy | ±0.2% F.S. |
|---|
| Power Resolution | 0.001 |
|---|
AC INPUT
| Wiring Code | 3pH+N+PE |
|---|
| Frequency (Hz) | 47-63 |
|---|
| Voltage Range (V) | 380V±15% |
|---|
| Power Factor | 0.99 @ Full-Load |
|---|
| Efficiency | >94% |
|---|
| Harmonic Current | ≤3% |
|---|
MISCELLANEOUS
| Protection Functions | Input Protection: Over/Under Voltage, Over/Under Frequency, Phase LossOutput Protection: Over Voltage/Over Current/Over Power, Internal Overtemperature, etc. |
|---|
| Communication Interfaces | Standard: LANOptional: RS485, CAN |
|---|
| External Interlock | External Interlock: NO/NC Input & Output |
|---|
| Trigger Signals | Trigger: Input/Output |
|---|
| Control & Display | Local touchscreen control with remote PC monitoring Real-time display of voltage, current, power and operational trends |
|---|
| Insulation & Dielectric Strength | 10MΩ/DC500V; 3600VAC(5000VDC)/1min |
|---|
| Cooling Method | Forced air cooling |
|---|
| Noise | ≤70dB |
|---|
| Operating Temperature | -10°C to +40°C |
|---|
| Relative Humidity | 10% to 90% RH (non-condensing) |
|---|
| Operating Altitude | ≤2000m |
|---|