TITAN Series
Solar Array Simulator
Utility-Scale and MW PV Source Emulation for PCS & Inverter Validation



The TITAN Series Solar Array Simulator is a high-power, programmable DC test platform designed for accurate photovoltaic source emulation under dynamic operating conditions. Validated through deployment in projects involving TÜV SÜD, Huawei, and multiple independent laboratories and certification institutes, the TITAN Series reproduces real-world PV array I–V characteristics with high temporal resolution. This enables reliable validation of PV inverters, DC/DC stages, and grid-connected energy systems during rapid irradiance transitions, transient operating events, and long-duration operational testing.

Engineered for both laboratory qualification and utility-scale validation, the TITAN Series integrates standard-compliant I–V curve models, programmable test sequences, and flexible operating modes into a unified test platform. Built-in support for EN 50530 and Sandia SAS methodologies allows repeatable MPPT performance evaluation and dynamic behavior analysis without external modeling tools, while CE-certified configurations extend applicability to regulated and industrial test environments.

Highlighted Features
  • 20–1500/2000 VDC output, scalable to 10 MW via parallel operation
  • High-resolution I–V emulation with up to 4096 points and 100 ms curve update
  • I–V curves generation using Voc, Isc, and fill factor, with optional CSV-based curve import.
  • Emulation of monocrystalline, polycrystalline, and amorphous silicon PV cell characteristics
  • Fast dynamics with voltage slew rates up to 300 V/ms for transient MPPT testing
  • Regenerative operation supports DC-side energy sinking with up to 94% efficiency
  • High-speed control and measurement up to 1 kHz, accuracy ±0.01% F.S.
  • Built-in PV models compliant with EN 50530 and Sandia SAS
  • Supports steady-state, dynamic irradiance, partial shading, and diurnal test profiles
  • Dynamic real-world simulations with day-long solar variation options
  • Flexible control options via Ethernet/USB/RS232/RS485/GPIB/APG
Model Options
Features
Applications
Specifications
Downloads
FAQs
Version History

FAQs for Solar Array/Panel Simulators and PV Emulation

› What is the difference between a solar panel simulator and a solar array simulator?

A solar panel simulator typically refers to a low-power PV source emulator used for component-level or laboratory testing, often limited to a single module or small string configuration. A solar array simulator, by contrast, is designed to replicate the electrical behavior of large-scale PV arrays operating at high voltage and power levels.

The TITAN Series is positioned as a solar array simulator, supporting output voltages up to 1500 VDC and scalable power levels from hundreds of kilowatts to multi-megawatt systems, making it suitable for string inverter, central inverter, and utility-scale PCS validation.

› How does TITAN support EN 50530 MPPT testing requirements?

EN 50530 requires the PV source to reproduce defined I–V curves across multiple irradiance levels while introducing controlled and repeatable irradiance transitions for evaluating both static and dynamic MPPT efficiency.

  • High-resolution I–V curve emulation with up to 4096 points
  • Fast curve switching intervals down to 100 ms
  • Stable steady-state operation for accurate efficiency measurement

These capabilities ensure MPPT performance is evaluated according to the standard rather than being influenced by source-side dynamics.

› How is dynamic MPPT testing according to Sandia SAS implemented?

The Sandia SAS methodology focuses on evaluating MPPT response speed and stability during rapid irradiance fluctuations such as cloud transients and partial shading events.

  • Sequential I–V curve updates representing rapid irradiance changes
  • Deterministic timing and repeatable curve transitions
  • Fast electrical response to minimize overshoot and settling artifacts

This enables consistent assessment of MPPT settling time, tracking accuracy, and control stability.

› Why is fast I–V curve update speed important for MPPT validation?

During MPPT testing, especially under dynamic conditions, the PV source must update its I–V characteristics faster than the inverter’s control loop. Slow source response can artificially influence MPPT behavior and lead to inaccurate results.

With curve update intervals as fast as 100 ms and voltage slew rates up to 200 V/ms, TITAN ensures observed MPPT performance reflects inverter algorithms rather than simulator limitations.

› Does PV simulation require bidirectional (regenerative) operation?

Under ideal conditions, a PV array is a unidirectional energy source. However, during system-level inverter and PCS testing, transient reverse energy flow may occur during startup, shutdown, fault handling, or control transitions.

TITAN supports regenerative current sinking on the DC side, safely returning absorbed energy back to the grid. This is particularly valuable for high-power and long-duration tests, reducing thermal stress and operating costs.

› Can TITAN simulate real-world PV conditions such as partial shading and cloud transients?

Yes. TITAN supports dynamic I–V curve sequencing to emulate:

  • Rapid irradiance fluctuations caused by moving clouds
  • Partial shading scenarios affecting array operating points
  • Temperature-dependent shifts in PV characteristics
  • Extended diurnal irradiance profiles

All scenarios can be executed through programmable test recipes with deterministic and repeatable behavior.

› Is TITAN suitable for use in certification and accredited laboratory environments?

CE-certified TITAN configurations are designed for deployment in accredited laboratories and certification institutes. Built-in standard-compliant PV simulation workflows and high measurement accuracy support certification testing according to EN 50530, Sandia SAS, and regional requirements.

› How does TITAN scale from laboratory testing to utility-scale validation?

TITAN uses a modular architecture with power blocks ranging from 300 kW to 750 kW, which can be paralleled to scale output power up to 10 MW. This allows consistent test methodology while expanding power capability as inverter ratings increase.

› Can custom or field-measured I–V curves be used for testing?

Yes. In addition to standard-compliant PV models, TITAN allows users to generate or import custom I–V curves based on parameterized models or measured field data. This supports R&D, beyond-standard validation, and regression testing under realistic operating conditions.

› Why use a solar array simulator instead of real PV panels for testing?

Real PV panels are subject to uncontrollable environmental variations and cannot provide the repeatability, precision, or dynamic control required for standardized MPPT and inverter validation tests.

A solar array simulator such as TITAN provides deterministic I–V behavior, controlled irradiance transitions, and repeatable test conditions, enabling accurate performance comparison across development, qualification, and certification stages.

Downloads

Technical resources in relation to the listed system and equipment

Version History

This product represents a continuation of ActionPower’s solar array simulation platform.

  • Previously: APS DC Power Supply – Solar Array Simulator
  • Current: TITAN Series Solar Array Simulator (series renaming and model update)

Core photovoltaic simulation capabilities—including I–V curve emulation, dynamic irradiance response, and application coverage—remain continuous across the product line. CE-certified TITAN configurations are available for selected models to support compliant testing and validation in regulated markets.

CE-Certified Model Options

Find the right specification for your requirements

ModelPower (kW)Output Voltage (V)Output Current (A)Dimensions (mm) W × H × D
TD300-1K5-04±30020~1500±4002010×1955×1200
TD400-1K5-06±40020~1500±6002010×1955×1200
TD500-1K5-07±50020~1500±7002010×1955×1200
TD600-1K5-08±60020~1500±8003410×1955×1200
TD750-1K5-10±75020~1500±10003410×1955×1200

Non-CE-Certified Model Options

Find the right specification for your requirements

ModelPower (kW)Max Voltage (V_DC)Output Current (A)Size (mm)Weight(kg)
TD300-1K2-10±30012-1200±10002010x1955x12002,640
TD400-1K2-10±40012-1200±10002010x1955x12002,850
TD500-1K2-12±50012-1200±12502010x1955x12003,020
TD600-1K2-12±60012-1200±12502410x1955x12003,500
TD300-2K0-04±30020-2000±4001610x1955x12001,900
TD400-2K0-06±40020-2000±6001610x1955x12002,430
TD500-2K0-07±50020-2000±7002010x1955x12002,670
TD600-2K0-08±60020-2000±8003410x1955x12003,500
TD750-2K0-10±75020-2000±10003410x1955x12004,390
TD1K0-2K0-14±100020-2000±14003410x1955x12004,940

Highlighted Technical Advantages

Advanced high-power solar array simulator with flexible SAS mode, I-V curve simulation functions, and powerful programming capabilities.


Scalable Solar Array Simulation from Hundreds of kW to Multi-MW Systems

Covering power range spanning from component-level and string inverter validation to utility-scale central inverter and PCS testing, TITAN series is designed with modular power blocks ranging from 300kW to 750kW meanwhile available for parallel connection to deliver scalable output power up to 10 MW with inter-cabinet communication and dynamic specifications uncompromised thanks to ActionPower's advanced hardware technologies.

Users benefit from such a technically uncompromised upscalability  to grow alongside evolving PV system ratings without complete hardware replacement. Flexible system setups and implementations are enabled for consistent test methodology across different power levels while preserving identical I–V emulation fidelity and dynamic performance.

10MW high power scalability

dynamic I-V curve simulation capability

High-Fidelity Dynamic I–V Curve Emulation for MPPT Validation

TITAN reproduces real-world photovoltaic array behavior through high-resolution I–V curve emulation with up to 4096 discrete points which is the market-leading resolution capability. Curve update and switching intervals as fast as 100 ms allow accurate reproduction of rapid irradiance transitions, partial shading events, and temperature-dependent operating shifts. Engineers can generate both standard-compliant and user-defined I-V curves for variant testing purposes.

Both static I–V curves for steady-state MPPT efficiency evaluation and dynamic I–V sequences for transient MPPT tracking analysis are supported, ensuring realistic validation of inverter control algorithms under practical operating conditions.

sandia static I-V Curve profile
Static I-V Curve Sandia Profile

I-V Curve EN50530 Curve Profile
Static I-V Curve EN50530 Profile

static I-V Curve MPPT
Static MPPT Profile

Dynamic MPPT I-V Curve
Dynamic MPPT Profile

I-V Curve programming interface
I-V Curve Programming Interface

Shade MPPT simulation I-V Curve interface
Shading Simulation Interface


Standards-Ready PV Testing with Programmable Scenario Control

The built-in operation interfaces of TITAN are embedded with PV simulation models and test workflows support EN 50530 and Sandia SAS methodologies. Users do not have to rely on any external modeling tools for generating regulation-required testing patterns. In addition to predefined standards-based recipes, engineers can import, edit, and sequence custom I–V curves via CSV files or parameterized models using Voc, Isc, fill factor, and temperature coefficients.

Complex test scenario - including sequential fault injection, irradiance ramps, and extended cycling profiles - can be executed through programmable test recipes with up to 1,000 steps and 10,000-cycle operations.

inverter testing application of TITAN DC Power Supply

DC titan solar panel simulator high dynamics

Essential High Dynamic Performance for Transient and Stability Analysis

Optimized power stage design enables fast electrical response suitable for demanding dynamic tests:

  • Voltage slew rate: up to 200 V/ms
  • Load rise/fall time (10–90%): < 2.5 ms
  • Current switching time (±90%): < 5 ms
  • Low overshoot and undershoot during abrupt load transitions

Above-mentioned characteristics ensure stable and repeatable operating conditions during inverter startup, MPPT perturbation cycles, and control-loop stress testing, which are impractical if tested with real solar arrays whose output is rather uncontrollable and dynamic-lacking.

 Current Rise Time (10% to 90%) 2.4 ms
Current Rise Time (10% to 90%): 2.4 ms

 Current Fall Time (90% to 10%) 2.4 ms
Current Fall Time (90% to 10%): 2.4 ms

 Current Switching Time (-90% to +90%) 4.8 ms
Current Switching Time (-90% to +90%): 4.8 ms

 Current Switching Time (+90% to -90%) 4.8 ms
Current Switching Time (+90% to -90%): 4.8 ms

 

Voltage Overshoot During Sudden Load 500 V applied 24 V
Voltage Overshoot During Sudden Load (500 V applied): 24 V

Voltage Undershoot During Sudden Load Removal (500 V removed) 22 V
Voltage Undershoot During Sudden Load Removal (500 V removed): 22 V

Voltage Transition Time at 200 V/ms Rate (from 136 V to 536 V): 2.04 ms
Voltage Transition Time at 200 V/ms Rate (from 136 V to 536 V): 2.04 ms

Voltage Transition Time at 200 V/ms Rate (from 136 V to 536 V): 2.04 ms
Switching interval between 2 sets of I-V Curve is of only 100 ms


Regenerative Architecture for High-Power and Long-Duration Testing

TITAN is in nature a DC power supply with bidirectionality, benefiting from which feature, and if necessary, the bidirectional power flow is allowed to achieve efficient current sinking from the DUT during inverter operation. Regenerative operation returns up to 94% of absorbed energy back to the grid, consequently significantly reducing thermal stress, energy consumption, and operating cost in multi-hundred-kilowatt and megawatt-level PV testing environments.

discover advantages of regenerative power supply

comprehensive rint internal resistance simulation interface  

Internal Resistance Emulation for Realistic Compromised Efficiency of PV Array

Temperature variations and uneven irradiation are inevitable with a real solar array system, which causes the power generation to be non-ideal. TITAN is programmable by internal resistance (Rint) emulation to replicate real-world PV source behavior under varying irradiance, weather, and temperature conditions.

By adjusting source impedance dynamically, engineers can evaluate MPPT robustness, control stability, and inverter response under realistic cable, array, and environmental effects beyond idealized I–V curves.


Precision Measurement and Deterministic Control

High-speed measurement and command refresh rates up to 1 kHz, combined with ±0.01% F.S. voltage and current accuracy, provide deterministic control and accurate data capture for ripple analysis, transient evaluation, and performance benchmarking across operating points.

Comprehensive Protection and Diagnostic Capabilities

Multi-layer protection mechanisms, including programmable OVP, OCP, OPP, and OTP to ensure safe operation for both the simulator and the device under test. Integrated fault logging records up to 200 events, with dedicated diagnostic queries supporting maintenance analysis, system integration, and long-term reliability tracking.

dc power supply protection functions

Test Applications of TITAN Solar Array Simulator

Discover use cases, DUTs, applicable standards and regulations


PV Inverter MPPT Performance and Compliance Testing

DUT: Central Inverters / PCS

Relevant standards: Grid codes, manufacturer validation procedures

For utility-scale PV plants, DC-side testing extends beyond MPPT efficiency to include system-level validation of inverters and PCS units under high power and wide voltage operating conditions. These tests often involve startup sequences, power ramping, protection triggering, and recovery behavior, where transient energy flow and control interactions must be evaluated.

Typical validation requirements include:
  • Stable operation across the full DC voltage range up to 1500 VDC
  • High-power operation from several hundred kilowatts to multi-megawatt levels
  • Tolerance to transient reverse energy flow during inverter shutdown, fault handling, or control transitions
  • Long-duration operation for thermal and stability assessment

TITAN’s modular architecture supports scalable DC output from 300 kW up to 10 MW, enabling consistent test execution across different inverter ratings. Regenerative DC-side operation allows absorbed energy to be returned to the grid with up to 94% efficiency, reducing thermal stress and energy consumption during extended high-power system tests.

 power conversion system and string inverter

hybrid inverter in solar pv farm

Dynamic PV Source Emulation for Environmental Stress Testing

DUT: PV Inverters / Hybrid Inverters

Relevant standards: Extended MPPT tests, custom qualification procedures

Beyond standardized MPPT efficiency tests, inverter robustness must be verified under realistic environmental variations such as rapid irradiance fluctuations, partial shading, and temperature-dependent PV behavior. These scenarios require the test source to modify its I–V characteristics dynamically while maintaining stability and repeatability.

Key test characteristics include:
  • Sequential I–V curve updates representing cloud transients and shading events
  • Time-correlated variation of PV parameters rather than isolated steady-state points
  • Repeatable execution of long-duration diurnal profiles

TITAN supports dynamic scenario emulation through programmable I–V curve sequencing, multi-step test recipes, and deterministic execution of complex profiles. Fast electrical response and stable control ensure that inverter behavior under stress is driven by source conditions rather than test system artifacts.


PV Control Algorithm Development and Verification

DUT: Inverter Control Platforms / R&D Prototypes

Relevant standards: Manufacturer-specific development workflows

During inverter development, control algorithms must be validated against a wide range of PV source behaviors, including non-ideal conditions that may not be fully covered by certification standards. These tests focus on MPPT robustness, control-loop stability, and fault tolerance under parameterized source conditions.

Typical development requirements include:
  • Arbitrary I–V curve generation based on user-defined PV parameters
  • Fine resolution and repeatability for regression testing
  • Deterministic response to rapid operating point changes

TITAN enables flexible PV source modeling through parameterized I–V curve generation and imported curve data, allowing engineers to correlate control decisions with electrical response using high-speed measurement and control refresh rates up to 1 kHz and ±0.01% F.S. accuracy.

Advanced Curve Simulation
  • Static/Dynamic I-V Curve generation with 4,096-point precision
  • MPPT Efficiency Testing compliant with EN50530 & Sandia standards
  • Shading Simulation for real-world scenario replication
  • Programmable Curves (200 steps, 999 cycles) supporting Step/List/Wave modes
  • Key Testing Features
  • Wide parameter ranges: Voc up to 2,000V, Fill Factor 0.3-0.95
  • Dynamic Response: 200V/ms slew rate, <5ms load transitions
  • Multi-panel emulation: c-Si, Thin-film, and custom PV profiles
  • dynamic MPPT I-V Curve for MPPT design

    Laboratory Qualification and Certification Testing

    DUT: PV Inverters under Certification

    Relevant standards: EN 50530, Sandia SAS, regional certification requirements

    Certification testing requires a PV source emulator that delivers repeatable, traceable, and standard-compliant behavior across multiple test campaigns. The DC source must not introduce unintended dynamics that could compromise test integrity or repeatability.

    CE-certified TITAN configurations are suitable for use in accredited laboratories, supporting standardized MPPT procedures, dynamic performance tests, and extended operational validation within a unified platform. Scalable power architecture allows laboratories to cover a broad range of inverter ratings without changing test methodology or equipment.

    Certification-Ready Testing
  • Preloaded EN50530/Sandia test protocols for MPPT certification
  • Grid-compliance validation: <3% THD, PF≥0.99 input characteristics
  • Audit-friendly with 200-event fault logging and data export
  • Precision Calibration
  • Reference-grade accuracy for calibrating low-precision instruments
  • Stable output (±24V fluctuation at 500V step loads)
  • Programmable impedance to compensate for test rig losses
  • manufacturer and laboratory standard testing

    Specifications

    The following specifications are subject to modifications and changes without notification in advance. All specifications measured are at product's maximum ratings, if not otherwise noted.

    GENERAL SPECIFICATIONS

    Output ModesConstant Voltage (CV), Constant Current (CC), Constant Power (CP), Programmable Output, and PV Standards (EN50530/Sandia) for Static and Dynamic MPPT Tracking and Solar Array Simulation
    Energy RegenerationPower sinking and regenerative feedback to grid
    Electrical IsolationInput/Output Electrical Isolation
    Parallel Operation CapabilityMultiple Units of the Same Model Can Be Paralleled

    DC OUTPUT

    VOLTAGE
    Setting Resolution0.01
    Accuracy±0.1 F.S.
    RMS Ripple0.1% F.S. (Resistive Load)
    Voltage Swing Rate300V/ms
    CURRENT
    Setting Resolution0.01
    Accuracy±0.1 F.S.
    RMS Ripple0.2% F.S. (Resistive Load)
    Rise Time2.5ms (10%-90% @ rated current)
    Switching Time5ms (between -90% and +90%)
    I-V CURVE
    Open Circuit Voltage (Voc) Setting Range20-1500V
    Short Circuit Current (Isc) Setting Range1A-le
    Simulated Fill Factor (FF) Range0.3-0.95
    PV Panel Type Selectionc-Si, Thin-film, Custom
    I-V Curve Update RateTypical 100ms response time with online curve switching capability
    I-V Curve EditingEN50530, Sandia, simple custom curves; Static MPPT curves; Dynamic MPPT curves; Shading profiles
    Points per Curve4096
    Curve Configuration
  • Custom I-V curve configuration via Voc, Isc, FF, Pm parameters
  • Built-in I-V curve database with >100 preloaded curves
  • Dynamic operation mode accounts for environmental factors (temperature, irradiance) with continuous output of environment-specific I-V curves
  • Built-in EN50530 dynamic I-V curve test procedure
  • UNIVERSAL PROGRAMMING FUNCTIONS
    Programming Steps200 steps
    Programming ParametersVoltage/Current, Rise Time, Hold Time, Trigger Pulse Output
    Rise Time Range1ms ~ 99999s
    Flat Top Time Range1ms ~ 99999s
    Minimum Programming Time Step1ms
    Edit ModeAdd, Delete, Import, Export
    Operation ModeRun, Stop, Cycle
    Trigger ModeAuto, Manual, External

    MEASUREMENT SPECIFICATIONS

    Voltage Accuracy±0.1% F.S.
    Voltage Resolution (V)0.001
    Current Accuracy±0.1% F.S.
    Power Accuracy±0.2% F.S.
    Power Resolution0.001

    AC INPUT

    Wiring Code3pH+N+PE
    Frequency (Hz)47-63
    Voltage Range (V)380V±15%
    Power Factor0.99 @ Full-Load
    Efficiency>94%
    Harmonic Current≤3%

    MISCELLANEOUS

    Protection Functions
  • Input Protection: Over/Under Voltage, Over/Under Frequency, Phase Loss
  • Output Protection: Over Voltage/Over Current/Over Power, Internal Overtemperature, etc.
  • Communication Interfaces
  • Standard: LAN
  • Optional: RS485, CAN
  • External Interlock
  • External Interlock: NO/NC Input & Output
  • Trigger SignalsTrigger: Input/Output
    Control & DisplayLocal touchscreen control with remote PC monitoring
    Real-time display of voltage, current, power and operational trends
    Insulation & Dielectric Strength10MΩ/DC500V; 3600VAC(5000VDC)/1min
    Cooling MethodForced air cooling
    Noise≤70dB
    Operating Temperature-10°C to +40°C
    Relative Humidity10% to 90% RH (non-condensing)
    Operating Altitude≤2000m

    Access our Download Center and Find Out Related Data Sheets

    From detailed integration manuals to the latest firmware, our Download Center provides the technical depth required for high-precision power electronics development. Enhance your ActionPower systems today.

    Access Download Center

    CONTACT US FOR PV POWER SIMULATOR SYSTEM

    Global Contact

    Sales Network & Locations

    If you are looking for an automated test system to validate your products during development and research stages to make sure of their successful commercial launch, ACTIONPOWER will be at your disposal to study your specifications and requirements to provided either standard or customized testing solutions.

    Join Our Network as a Distributor?

    Interested in ACTIONPOWER's testing solutions and equipment and want to promote them in your market? Contact us to joint our global sales network to grow together as partners.

    Quick Model Access

    Smart Discovery

    Access our Power Supply Wizard to find the right programmable power supply for your use cases and testing scenarios.

    discover programmable power supply by filtering with current, voltage and power ranges
    CONTACT US

    Contact Us

    Professionalism is what we care about. Why not email us with your technical requirements fully explained rather than submitting a simple message so that we revert more proactively with detailed solutions?

    Subscribe to Newsletter

    Thank you for subscribing!