NEXUS SERIES
Regenerative AC Power Supply
High power 4-quadrant AC source-load with comprehensive emulation capability
NEXUS regenerative AC power supply is the alternating current variant of NEXUS DC Power Supply and further equipped with comprehensive emulation capabilities and programming functions. NEXUS AC Power Supply applies for grid compliance and compatibility validation through bidirectional architecture and versatile grid emulation functions, addressing critical testing needs in the renewable energy sector including anti-islanding protection and off-grid load simulation.
As programmable source-load unit with auto-ranging functions with high performance and technical specifications, NEXUS features advanced regenerative load technology that recovers up to 100% the current back to the grid with a regenerative efficiency of 91% and thus minimizing energy consumption, reducing operational costs.
Highlighted Features
- High power density of 173kVA/m3 and compact footprint that saves 52% space utilization
- Ultimate response and dynamics with slew rate of more than 1.oV/μs
- Maximum AC output voltage up to 900V, 4MVA maximum AC output power
- Rise and fall time of 100μs@90%-10%
- Scalability at both modular and rack level, flexible upgrading without replacing the system
- Built-in comprehensive recipes of testing standards and abnormal grid condition emulation
- Linear and non-linear load emulation capabilities
Model Options
Find the right specification for your requirements
NEXUS is going through model update. Specifications and options in the table may have not been updated in due time. Consult representatives at ActionPower for more support.
| Models | Power (kVA) | Output Voltage (V) | Frequency (Hz) | Current (A) | DC Output Voltage (V_DC) |
DC Output Current (A_DC) |
Size (mm) | Weight (kg) |
|---|---|---|---|---|---|---|---|---|
| NA090-470 | 90 | 470 | DC, 0.001-200.0 | 200 | ±650 | ±600 | 800x1000x1950 | 600 |
| NA180-470 | 180 | 470 | DC, 0.001-200.0 | 400 | ±650 | ±1200 | 800x1000x1950 | 800 |
| NA225-470 | 225 | 470 | DC, 0.001-200.0 | 500 | ±650 | ±1500 | 800x1000x1950 | 900 |
| NA270-470 | 270 | 470 | DC, 0.001-200.0 | 600 | ±650 | ±1800 | 1400x1000x1950 | 1,310 |
| NA360-470 | 360 | 470 | DC, 0.001-200.0 | 800 | ±650 | ±2400 | 1400x1000x1950 | 1,510 |
| NA450-470 | 450 | 470 | DC, 0.001-200.0 | 1000 | ±650 | ±3000 | 1400x1000x1950 | 1,710 |
| NA540-470 | 540 | 470 | DC, 0.001-200.0 | 1200 | ±650 | ±3600 | 2000x1000x1950 | 2,220 |
| NA630-470 | 630 | 470 | DC, 0.001-200.0 | 1400 | ±650 | ±4200 | 2000x1000x1950 | 2,420 |
| NA675-470 | 675 | 470 | DC, 0.001-200.0 | 1500 | ±650 | ±4500 | 2000x1000x1950 | 2,520 |
| NA540-900 | 540 | 900 | DC, 0.001-200.0 | 600 | ±1250 | ±1800 | 2000x1000x1950 | 2,220 |
| NA630-900 | 630 | 900 | DC, 0.001-200.0 | 700 | ±1250 | ±2100 | 2000x1000x1950 | 2,420 |
Highlighted Features
Advantages and functions of NEXUS Regenerative AC Power Supply
Source-Load Power Supply with 4-Quadrant Operation Capability
NEXUS Regenerative AC Power Supply combines both AC power source and regenerative electronic load in one system. The regenerative load technology allows the system to recover the current up to 100% back to grid with a regenerative efficiency of 91% the saves considerably energy testing cost.
High Power and Technical Ratings
Maximum voltage up to 600V, and scalable up to 4MVA AC output power by parallel expansion though optical fiver communication without compromising precision, accuracy, dynamics, and response.
High-Power Density and Compact Footprint
NEXUS Regenerative AC Power Supply achieves high power density at 173kVA per cubic meter (cbm) thanks to the advanced power electronics technology and compact footprint. NEXUS's high power density feature optimizes the system utilization by 54% and reduces weight by 52% compared to conventional solutions. Laboratories and production lines can benefit from NEXUS as a powerful solution with minimal footprint to upscale their productivity per area.
Scalability at both Modular and Rack Level, Redundancy and Low Maintenance Features
NEXUS Regenerative AC Power Supply features modular system architecture with fault redundancy capability. In the event of equipment failure, redundant backup components quickly take over, ensuring controllable repair time and maximum protection of production efficiency.
The system is unscalable at both modular and rack level. Users can achieve higher rated power to meet evolving test specifications either by adding more racks to their existing system or by incorporating more modules with in the rack. The unique modular and rack-level scalability addresses long-term value and serviceability waiving the necessity of repurchase.
Grid-Tied Device Validation: Anti-Islanding Protection Testing Capability
NEXUS‘s comprehensive grid emulation capability highlights its advantages in validating grid-tied devices in renewable energy sector with its built-in anti-islanding protection testing capability. The exceptional technical specifications of NEXUS's capability covers anti-islanding protections for miscellaneous and ranges of products including energy storage systems (ESS), power conversion systems (PCS), microgrids, on-board chargers (OBC/BOBC), and uninterruptible power supplies (UPS).
Linear & Non-Linear Load Emulation
The NEXUS simulates both non-linear (2-24 pulse, adjustable crest factor) and linear loads (12 RLC models) for comprehensive testing. It regenerates power to the grid, expanding capacity without infrastructure upgrades. Ideal for grid-tied and off-grid devices (BOBC, UPS, PCS), simplifying ATE setups for V2G, V2L, and V2H testing.
Comprehensive Abnormal Grid Condition Emulation with Versatile Programming and Built-in Recipes
The NEXUS AC Power Supply comprehensively simulates grid anomalies with adjustable frequency, voltage, phase, and harmonic distortion (up to 50th order, 27 waveforms). Soft start minimizes inrush current. It emulates diverse loads using 12 RLC models, and performs 1ms interruption tests. Advanced programming modes (STEP, LIST, PULSE) and HVRT/LVRT testing with adjustable phase angles (phase control capability) with simultaneous control and 0.1° resolution for each of the 3-phase.
Built-in waveforms and recipes:
- IEC61000-4-11 Voltage Interrupt 90° @ Class 2 / 50Hz
- IEC61000-4-13 Non-Triplen Odd Harmonics @ Class 3 / 50Hz
- IEC61000-4-14 +20% -30% Voltage Fluctuation 0.2s @ Class 3 / 50Hz
- IEC61000-4-17 DC Ripple Voltage @ Class 3
- IEC61000-4-27 Voltage Unbalance @ Class 3
- IEC61000-4-28 Frequency Variation @ Class 4
- IEC61000-4-29 DC Voltage Interruption @ Class X
A Versatile DC Power Supply for Various Industries
Thanks to our bidirectional, regenerative technology, intelligent HMI and powerful software
PHOTOVOLTAIC
PRO bidirectional programmable power supply supports static I-V curve generation, curve scanning, and MPPT efficiency testing for accurate PV inverter validation.
Find Solutions
ELECTRIC VEHICLE
PRO bidirectional programmable power supply supports static I-V curve generation, curve scanning, and MPPT efficiency testing for accurate PV inverter validation.
Find Solutions
ENERGY STORAGE SYSTEM
Bidirectional power supplies can either sink and source power from or towards battery or to be used as dynamic testing equipment to simulate battery's operating characteristics to test other systems and devices.
Find Solutions
INDUSTRIAL VERIFICATION
The powerful functions and excellent operating metrics of ActionPower's power supplies are ideal for certificating and inspection companies to verify regulatory and standard compliance.
Find SolutionsSpecifications
The following specifications are subject to modifications and changes without notification in advance. All specifications measured are at product's maximum ratings, if not otherwise noted.
AC INPUT
| Voltages, Phases | 380V±15%, 3ph+PE |
|---|---|
| Frequency | 47Hz to 63Hz |
| Harmonic Current | <3% |
| Power Factor | >0.96 |
AC Output Voltage
| Setting Resolution | 0.01V |
|---|---|
| Accuracy | ±0.1 F.S. |
| DC Component | <50mV |
| Load Regulation | >±0.05 F.S. |
| Line Regulation | >±0.05 F.S. @ 10% variable |
| Voltage Slew Rate | AC>1.0V/μs |
| 3-Phase Balance | Does not exceed half of the requirements of GB/T 15543-2008 (negative sequence voltage does not exceed 1%, short-term does not exceed 2%) |
AC Output Current
| Accuracy | ±0.1%±0.1% F.S. @ 15-200Hz |
|---|
Output Frequency
| Range | DC, 0.001Hz-200.0Hz |
|---|---|
| Setting Resolution | 0.001Hz |
| Accuracy | ±0.01% |
Phase Angel Control
| Phase control | A=0°, B=240°, C=120°(Default) |
|---|---|
| Phase angle range | Programmable range 0 - 359.9° individual adjustable |
| Accuracy | ±0.1°@15-70Hz, ±0.5°@70-200Hz |
| Setting Resolution | ±0.1° |
Internal Resistor
| R Range | 0-10Ω(Impedance at steady-state output) |
|---|---|
| L Range | 0-2mH |
| Setting Resolution | 0.001 |
| Accuracy | 0.1%+0.2% F.S. |
Harmonic Injection
| Order | 100th@40Hz-70Hz, 25th@70Hz-200Hz |
|---|---|
| Content | 40% for individual, total content max.40% |
| Phase Angle Range | 0 - 359.9° |
| Amplitude Error | ±5% @0.1% of the set value or fundamental value |
| Preview Function | The superimposed waveform of harmonics can be previewed |
| Editing Mode | import, export, read, store |
Harmonic Injection
| Mode | List, Wave, Step, Pulse, Advanced, Harmonic, Inter-harmonic |
|---|---|
| Step | 100 steps |
| Cycle | 0 ~ 9,999,999 |
| Parameter | V oltage, Frequency, Phase, Variable period, Hold period, Phase angle, Phase pulse |
| Uptime Range | 100μs - 999s |
| Flat Top Range | 100μs - 999s |
| Minimum Programming Step | 100μs |
| Trigger output and Enable | Output a low-voltage trigger signal isolated electrically from other parts within the device, synchronized with the changes in power supply output parameters; single-step, single-cycle, single-shot triggering; (pulse) |
| Edition | Import; Export; Read; Store |
| Operation Mode | Run, stop, major cycle (9999999) + minor cycle nested programming (9999999) |
| Trigger Source | Local software, external hardware |
| Trigger Node | Automatic, manual, external |
DC Output Voltage
| Setting Resolution | 0.01V |
|---|---|
| Accuracy | ±0.1% F.S. |
| Ripple | <1.5Vrms@ (DC-60kHz) |
| Load Regulation | ±0.05% F.S. |
| Line Regulation | ±0.01% F.S.@10%variable |
| Slew Rate | DC>1.0V/μs |
DC Output Current
| Setting Resolution | 0.01A |
|---|---|
| Accuracy | ±(0.1%+0.1% F.S.) |
RLC Load
| Resistance range (Ω) : 0.001 to 1000 | Resistance resolution (Ω)) : 0.001 Resistance accuracy : ±0.1% F.S. |
|---|---|
| Inductors range (mH) : 0.1 to 5000 | Inductors resolution (mH) :0.001 Inductors accuracy : ±0.1% F.S. |
| Capacitance range (mF) : 1 to 5000 | Capacitance resolution (mF) : 0.1 Capacitance accuracy : ±0.1% F.S. |
| Crest factor range : 1.000 to 5.000 | Crest resolution : 0.001 |
| Power factor range : -1.000 to 1.000 | Power resolution : 0.001 |
Measurment
| Voltage Accuracy | ±0.1% F.S. |
|---|---|
| Frequency Accuracy | ±0.1% |
| Current Accuracy | ±(0.1%+0.2% F.S.) |
| Active Power Accuracy | ±0.5% F.S. |
| Apparent Power Accuracy | ±0.5% F.S. |
Miscellaneous
| Protection | Input under-voltage/over-voltage/over-frequency/phase loss protection
Output over-voltage/over-current/over-power/over-temperature protection |
|---|---|
| Communication Interface | USB, LAN, RS485, CAN |
| Multi-function Interface | “Anyport” see the user manual for more details |
| Operation | Local touchscreen control, remote host control; display voltage, current, frequency, power |
| Cooling Mode | Air Cooling |
| Noise | ≤70dB |
| Operation Temperature | -10℃~50℃ |
| Humidity | 10% ~ 90% RAH |
| Altitude | ≤2000m |
Change Log
Find records of in which terms has the product been updated
- Previously: PRO Regenerative AC Power Supply
- Updated on Sept 10th, 2025: NEXUS Regenerative AC Power Supply (Model Update)
Access our Download Center and Find Out Related Data Sheets
From detailed integration manuals to the latest firmware, our Download Center provides the technical depth required for high-precision power electronics development. Enhance your ActionPower systems today.
INQUIRE FOR CABINET AC POWER SUPPLY

Sales Network & Locations
If you are looking for an automated test system to validate your products during development and research stages to make sure of their successful commercial launch, ACTIONPOWER will be at your disposal to study your specifications and requirements to provided either standard or customized testing solutions.
Join Our Network as a Distributor?
Interested in ACTIONPOWER's testing solutions and equipment and want to promote them in your market? Contact us to joint our global sales network to grow together as partners.