CORTEX Series
Programmable Bidirectional DC Power Supply

3U / 30 kW regenerative source and load platform for precision DC testing



CORTEX is a next-generation bidirectional programmable DC power supply that integrates precision DC source, regenerative electronic load, and automatic two-quadrant operation in a compact 3U, 19-inch rack-mount platform. The modular internal architecture of CORTEX combines AC input conversion, bidirectional isolated DCDC power stages, output filtering, and digital control boards into a high-density power module designed for battery, EV, energy storage, and power electronics testing, featuring 30kW high-power density, scalable structure and improved cooling frame.

During operation, CORTEX can both source power to the DUT and sink returned energy through regenerative feedback, helping reduce heat loss and test energy consumption. With high-accuracy voltage & current measurement, microsecond-level dynamic response, scalable power modules, and an airflow-optimized structure, the CORTEX series is built for precision R&D validation, production testing, and integrated cabinet systems.

Highlighted Features  

  • Microsecond-level dynamic response for fast transient testing
  • 6.5-digit voltage and current measurement accuracy
  • Automatic source/sink switching with two-quadrant operation
  • Regenerative energy feedback during electronic load operation
  • Scalable parallel system: up to 100 units and 3 MW total power
  • Up to 240 kW integrated in a single 42U cabinet
  • Maintains measurement accuracy during power expansion
  • Multiple output modes: CV, CC, CP, and CR
  • Battery simulation for charge/discharge test profiles
  • Built-in EN 50530 and Sandia profiles for solar array simulation
Model Options
Features
Applications
Specifications
FAQs

Technical FAQs About CORTEX Bidirectional DC Power Supply

These FAQs explain the engineering behind CORTEX, including regenerative source/load operation, compact rackmount power density, internal airflow design, busbar-style interconnection, modular maintenance, and parallel system expansion. The modular power architecture is also referenced in ActionPower's published patent application CN121791654A .

› What makes CORTEX a bidirectional DC power supply?
CORTEX operates as both a programmable DC source and a regenerative DC load. In source mode, it delivers controlled DC power to the device under test. In sink mode, it absorbs current returned from the DUT, enabling bidirectional source and load testing in one platform.
› How does regenerative operation help reduce energy loss?
During load operation, conventional electronic loads usually dissipate absorbed energy as heat. CORTEX uses regenerative technology to return recoverable energy through its internal power conversion path, helping reduce heat generation, cooling demand, and wasted energy during high-power testing.
› How does CORTEX achieve high power density in a compact chassis?
CORTEX uses a modular internal architecture that integrates input filtering, rectification, bus transfer, bidirectional power conversion, output filtering, and digital control into a compact rackmount structure. This stacked layout helps improve power density while keeping functional sections clearly organized.
› How is the bidirectional power conversion stage designed?
The internal bidirectional conversion stage uses a compact board-level arrangement that places the power conversion and control sections close together. This helps shorten internal connection paths, improve assembly consistency, and support a cleaner high-density power module design.
› How does CORTEX manage heat during source and sink operation?
CORTEX uses a structured internal cooling layout with a central fan assembly and separated airflow paths. Heat-generating power components are positioned within defined cooling zones, supporting thermal management during continuous source operation and regenerative load operation.
› Why does airflow structure matter in bidirectional testing?
Bidirectional testing can create sustained thermal stress, especially when the equipment is absorbing returned energy from the DUT. A defined airflow structure helps remove heat from power components, control sections, and expansion boards more effectively than an unorganized open chassis layout.
› What is the benefit of busbar-style internal interconnection?
CORTEX reduces dependence on loose internal wiring by using conductive posts and busbar-style interconnections between key power sections. This helps shorten high-current paths, reduce wiring complexity, improve assembly repeatability, and make the internal structure easier to inspect and maintain.
› How does CORTEX support modular maintenance?
CORTEX is built around modular subassemblies, including the front HMI, power module, input distribution section, rear panel, output protection area, and cover structure. This modular layout supports clearer internal partitioning, easier assembly, and more serviceable maintenance compared with densely wired conventional designs.
› How does CORTEX support parallel power expansion?
CORTEX supports scalable power expansion through synchronized parallel operation and high-speed communication between units. This allows multiple power supplies to work together as a higher-power DC test system for cabinet-level and large-scale applications.
› Does parallel operation affect control and measurement consistency?
CORTEX parallel expansion is designed to maintain coordinated control and measurement consistency across connected units. This is important for high-power battery, PCS, inverter, and production test systems where current sharing, stable response, and repeatable test results are required.
› What safety-related design features are built into CORTEX?
The internal design includes input surge suppression, circuit protection, grounding, insulation spacing, and output terminal protection. The output protection area is designed to improve operator safety while still allowing visual inspection during installation and maintenance.
› Why does the internal architecture matter for real test applications?
For battery, EV, PV, PCS, and DC converter testing, performance depends on more than headline power ratings. Thermal design, current path layout, control partitioning, serviceability, and cabinet integration all affect real test stability. CORTEX combines bidirectional power conversion, regenerative energy handling, organized airflow, modular construction, and scalable system expansion in one DC test platform.
     

CE-Certified Model Options

Find the right specification for your requirements

Product Model Power (kW) Voltage Level (V) Current Level (A) Size Weight (kg)
CD30-2K0B302000603U35
CD30-1K5B301500603U35
CD30-1K0B301000803U35
CD30-800B30800803U35
CD20-2K0B202000603U35
CD20-1K5B201500603U35
CD20-1K0B201000803U35
CD20-800B20800803U35
CD20-080B20806673U40
CD20-060B20606673U40
CD20-040B20406673U40
CD15-2K0B152000453U35
CD15-1K5B151500453U35
CD15-1K0B151000543U35
CD15-800B15800543U35
CD15-080B15806673U40
CD15-060B15606673U40
CD15-040B15406673U40
 

Non-CE-Certified Model Options

Find the right specification for your requirements

Product Model Power (kW) Voltage Level (V) Current Level (A) Size Weight (kg)
PRD4V50E15406673U40
PRD4V66E20406673U40
PRD6VS0E15606673U40
PRD6V66E20606673U40
PRD8VS0E15806673U40
PRD8V66E20806673U40
PRD0212E152001603U40
PRD0216E202002403U35
PRD0224302002403U35
PRD0312E153601603U35
PRD0316E203602403U35
PRD0324303602403U35
PRDO509E155001203U35
PRDO512E205001803U35
PRDO518305001803U35
PRD0609E156001203U35
PRDO612E206001803U35
PRD0618306001803U35
PRD0804E15800543U35
PRDO805E20800803U35
PRD080830800803U35
PRD1004E151000543U35
PRD100SE201000803U35
PRD1008301000803U35
PRD1503E151500453U35
PRD1504E201500603U35
PRD1506301500603U35
PRD2003E152000453U35
PRD2004E202000603U35
PRD2006302000603U35
PRD07305070030024U290
PRD076010070060024U390
PRD07120200700120036U720
PRD07180300700180030Ux21100
PRD07240400700240036Ux21430
PRD07300500700300036Ux31940
PRD151050150010024U290
PRD1520100150020024U390
PRD1540200150040036U720
PRD1560300150060030Ux21100
PRD1580400150080036Ux21430
PRD151005001500100036Ux31940
PRD201050200010024U290
PRD2020100200020024U390
PRD2040200200040036U720
PRD2060300200060030Ux21100
PRD2080400200080036Ux21430
PRD201005002000100036Ux31940

Highlighted Technical Features

Bidirectional programmable DC power supply with two-quadrant source/sink operation, regenerative energy feedback, high-accuracy measurement, fast dynamic response, and built-in battery and solar array simulation functions.


30 kW per 3U High Power Density Architecture

The CORTEX Series is designed as a compact 3U bidirectional programmable DC power supply delivering up to 30 kW from a single rackmount module. Its high-density architecture integrates AC input conversion, DC bus transfer, bidirectional isolated DCDC conversion, output filtering, and digital control into a vertically stacked internal structure.

Inside the power module, the input filter board 22, PWM rectifier power board 23, PWM rectifier chopper board 24, bus transfer board 25, bidirectional DC/DC+BUCK power board 26, DCDC control board 27, output filter assembly 28, outer-loop control board 29, and inner-loop control board 210 are arranged in a compact 3U chassis 21. Such a architecture helps CORTEX achieve high power density while maintaining clear functional partitioning for cooling, assembly, and maintenance.

Two side-by-side 3D models of the Cortex DC Bidirectional Programmable Power Supply. The left model shows the fully assembled unit with a grey metallic chassis and a dark front interface panel. The right model is an exploded view with the top cover hovering above the chassis, exposing complex internal circuitry, a prominent array of copper inductor coils, capacitors, and rear cooling modules.

A side-by-side product photograph of two high-precision electronic test instruments. On the left is an Actionpower Cortex DC Bidirectional Programmable Power Supply, featuring a dark front panel with a detailed display showing dual circular flow indicators for 'Source' and 'Load' and multiple 9-digit data points. On the right is a Keithley DMM7510 7-1/2 Digit Multimeter with a clear color touchscreen displaying a voltage reading of '+0.5000097 kV' (500 volts).

6.5-Digit Voltage and Current Measurement

CORTEX integrates a high-precision voltage and current measurement system with 6.5-digit resolution, reducing the need for external precision meters in many automated test setups. The high-fidelity measurement capability supports accurate DUT performance evaluation in applications such as battery testing, photovoltaic inverter validation, EV power electronics, and production quality control.


DMPS (Digital Matrix Parallel System) for Scalable Power

With DMPS, Digital Matrix Parallel System, multiple CORTEX units can be connected through high-speed fiber-optic communication for synchronized power expansion. The system supports scalable configurations up to 100 units and up to 3 MW total power.

For cabinet-level integration, CORTEX can deliver up to 240 kW in a standard 42U cabinet. The 19-inch rackmount structure follows standard cabinet integration practices and supports high-density multi-unit test systems.

Redundant Operation in Parallel Systems

In a configured parallel system, if a slave unit fails during operation, excluding output-side or AC-side protection events, the remaining units can redistribute current within the configured operating limits and continue the test process. This helps reduce downtime in long-duration reliability tests, burn-in systems, and production validation.

A detailed electrical system architecture diagram illustrating the master-slave cascading configuration of multiple Actionpower Cortex DC programmable power supply modules to achieve total output power levels of 300kW, 600kW, and 3MW. The diagram is structured in three distinct, horizontally connected sections, which from left to right represent 300kW, 600kW, and 3MW systems

Four operating envelope charts showing the relationship between output voltage and current for different programmable power supply models.

Auto-Ranging Capability

CORTEX DC power supply is an advanced DC source that can automatically adjust on its own the output voltage and current while maintaining its output power according to its rated level. The function extends is range of services in terms of testing scenarios to deliver its full maximum power output across wider combination ranges of voltage and current.

Alongside is a 2x2 grid of charts illustrating the arched operating envelopes of output voltage (Y-axis) versus output current (X-axis) for different product combinations:

  • Top-Left: Shows PR0324 (green zone, ~200V-350V) and PR0224 (yellow zone, ~0V-200V). The low-voltage area allows the maximum current (±300A).
  • Top-Right: Shows PR0618 (blue zone, high-voltage) and PR0518 (green zone, lower-voltage).
  • Bottom-Left: Shows PR01008 (yellow zone, up to 1000V) and PR0808 (purple zone, up to 800V). The current range is restricted to ±100A.
  • Bottom-Right: Shows ultra-high voltage models PR2006 (pink zone, up to 2000V) and PR1506 (yellow zone). The extremely high voltage restricts the allowable current to the lowest range (±60A).

Auto-Switching and Multiple Output Modes of CC, CV, CP, CR

CORTEX offers a flexible output mode switching thansk to which users are no longer required to pre-select a specific operating mode such as CV or CC as with those conventional programmable units. Rather, the mode switching with CORTEX DC is automatically realized based on user-defined target voltage and maximum current of the DUT against which the system automatically operates within these limits in either source or load mode and displays the active mode in real time. The function extends is range of services in terms of testing scenarios to deliver its full maximum power output across wider combination ranges of voltage and current.

CORTEX automatically realizes intelligent switching under Constant Voltage (CV), Constant Current (CC), and Constant Power (CP) modes based on \( P = U \times I \) for which the system maintains ontrolled parameter while allowing the others to vary with load conditions, and automatically transitions to the appropriate mode when any limit is reached to ensure safe and stable operation.

In Constant Resistance (CR) mode, the device maintains a programmed equivalent internal resistance, behaving like a voltage source with a series “virtual resistance.” This causes output voltage to drop with increasing current, enabling realistic power source emulation and load behavior evaluation.

Equivalent circuit comparison diagram for programmable internal resistance simulation. The left schematic shows an ideal voltage source circuit, where the set voltage (U_SET) is directly connected to the output, generating output voltage (U_OUT) and output current (I_OUT). The right schematic illustrates a circuit with internal resistance simulation, adding a variable series resistor (R_SET) between the voltage source (U_SET) and the output terminals, visually demonstrating the principle of simulating the internal voltage drop of a real battery or non-ideal power supply.

\(U_\text{set} - U_\text{out} = I_\text{out} \times R_\text{Set} \)

Circuit Diagram for CR under Source Mode

Equivalent circuit comparison diagram for programmable input resistance (or electronic load) simulation. The left schematic shows an ideal constant-voltage sink circuit, where the set voltage (U_SET) is directly connected to the input terminals, with a red arrow indicating the input current (I_IN) flowing into the device at input voltage (U_IN). The right schematic illustrates a circuit with input resistance simulation, adding a variable series resistor (R_SET) between the voltage source (U_SET) and the input terminals. This visually demonstrates the principle of simulating the internal resistance of a charging battery or line impedance when the device absorbs power.

\( U_\text{in} - U_\text{Set} = I_\text{in} \times R_\text{Set} \)

Circuit Diagram for CR under Load Mode

Six diagrams illustrating power supply operating modes. The top row shows V-I curves: CC Mode is a vertical line indicating constant current; CV Mode is a horizontal line for constant voltage; CP Mode is a hyperbolic curve for constant power; CR Mode is a diagonal line for constant resistance. The bottom row shows time-based waveforms: Dynamic Mode displays a repeating trapezoidal waveform transitioning between Load 1 and Load 2, with labeled Rise Rate, Fall Rate, durations T1 and T2, and Repeat Times; Programmable Sequences shows a complex multi-step waveform on an I vs. T graph, illustrating varying discrete current levels over time.

Battery Emulation Capability

The advanced programming capability of CORTEX bidirectional DC power supply lays the technical groundwork of its capability to simulate at complex and dynamic voltage and current response of a battery under various load conditions and state-of-charge. Along with a range of built-in battery type profiles, supported by its functional features, CORTEX is a valuable instrument for testing, developing, and validating battery-powered devices and systems without actually using a physical battery.

System topology diagram for a Bidirectional Onboard Charger (OBC) testing solution, showing the complete test link comprising a CORTEX DC Power Supply (battery emulation), the DUT, and a Regenerative Grid Simulator, with red and blue arrows indicating bidirectional energy flow paths during charging and V2X discharging modes.

PV Simulation Capability

CORTEX is with ability to accurately simulate the electrical behaviour of a photovoltaic (PV) array and mimics the complex current-voltage (I-V) characteristics of a solar panel under varying environmental conditions, serving as the DC source for testing, and validating solar inverters, maximum power point tracking (MPPT) algorithms, and other solar energy systems without relying on actual solar panels and unpredictable weather conditions.

System topology diagram of a Photovoltaic (PV) Inverter testing solution based on the CORTEX DC power supply, demonstrating the complete test link of simulating PV array characteristics via professional software (including SAS and Shadow modes) to drive the DC source, power the inverter, and ultimately connect to the grid.


Internal Framework and Architecture of CORTEX Bidirectional DC Power Supply

The CORTEX internal layout separates high-power conversion, filtering, control, cooling, and input/output protection into defined functional zones. A central fan assembly divides the chassis into front and rear power sections, while insulated partitions and insulating members form multiple airflow channels for thermal management.

Key layout references:
  • [22]: input filter board
  • [23]: PWM rectifier power board
  • [24]: PWM rectifier chopper board
  • [25]: bus transfer board
  • [26]: bidirectional DCDC+BUCK power board
  • [27]: bidirectional DCDC control board
  • [28]: output filter assembly
  • [29]: outer-loop control board
  • [210]: inner-loop control board
  • [213]: fan assembly
  • [214]: insulating members / airflow partition structure
3D rendering of the CORTEX Bidirectional DC Power Supply's internal components, featuring numbered callouts that correspond to the legend to map the spatial layout of PCBs, magnetic components, and cooling airflow channels.

Layout of CORTEX Bidirectional DC Power Supply

size layout drawing of CORTEX bidirectional DC Power supply

Bidirectional DC Power Supply Applications

From battery pack cycling and EV charger testing to PV inverter, DC/DC converter, PCS, and production burn-in systems, CORTEX combines programmable DC source, regenerative load, battery emulation, and solar array simulation in one scalable test platform.


EV On-Board Charger, OBC, Testing

For EV on-board charger testing, CORTEX can operate as a programmable battery emulator on the DC output side of the charger by replicating battery terminal voltage under different SOC conditions while absorbing the charger’s output power through regenerative load operation.

Onboard charger is thus validated against different operation curve profiles, protection behaviour, abnormal voltage conditions, startup & shutdown behaviour, and communication-controlled charging strategies without relying on a physical battery pack.

Applicable testing standards, dependent on specifications and configurations:

  • IEC 61851-1:2017:EV conductive charging system general requirements
  • IEC 61851-21-1:2017:EV on-board charger EMC requirements
  • ISO 15118-20:2022:vehicle-to-grid communication interface, includes bidirectional power transfer message requirements
  • SAE J1772_202401:North America EV/PHEV conductive charging coupler requirements

System topology diagram for a Bidirectional Onboard Charger (OBC) testing solution, showing the test link comprising a DC Power Supply, the DUT, and a Grid Simulator, with arrows indicating bidirectional energy flow paths during charging and V2X discharging modes.


A schematic diagram illustrating bidirectional energy flow between a power grid, a central bidirectional power supply unit, and an electric motor. A transmission tower icon on the left (representing the grid) and the central equipment are connected by red, bidirectional arrows. The central equipment is similarly connected to an electric motor icon on the right, with the arrow pointing to the motor labeled

EV Inverter DC Bus and Regenerative Braking Test

CORTEX can be used as a programmable DC bus emulator for EV traction inverter and motor drive testing. The bidirectional capability supports testing setup without adding separate braking resistors or oversized dissipative loads, with a single unit that supplies the inverter DC link during motoring operation and absorbs returned energy during regenerative braking or deceleration events.

Applicable testing standards, dependent on specifications and configurations:

  • ISO 16750-2:2023:vehicle electrical load conditions
  • ISO 6469-3:2021:electrical safety for electric propulsion systems
  • IEC 62477-1:2022:power electronic converter system safety

PV Inverter and MPPT Testing

With solar array simulation capability, CORTEX can emulate photovoltaic array I-V characteristics under changing irradiance and temperature conditions. It provides a programmable DC source for testing PV inverters, MPPT algorithms, DC/DC optimizers, and solar energy conversion systems. Built-in EN 50530 and Sandia profiles allow repeatable MPPT validation without depending on outdoor solar panels, unstable sunlight, or weather conditions.

Applicable testing standards, dependent on specifications and configurations:

  • IEC 62891:2020:MPPT efficiency measurement for grid-connected PV inverters
  • EN 50530:2010+A1:2013:overall efficiency of grid-connected PV inverters, including static/dynamic MPPT efficiency
  • IEC 61683:1999:PV power conditioner efficiency measurement
  • IEEE 1547-2018 / IEEE 1547.1-2020:DER interconnection and conformance test procedures

System architecture topology diagram for Photovoltaic (PV) Inverter testing. The left side illustrates using PC software to simulate Solar Energy and PV Array characteristics. In the center, a CORTEX DC Programmable Power Supply acts as the DC Source, with four advanced software test modes listed below: SAS Mode, Table Mode, Shadow Mode, and List Mode. The right side shows the complete energy flow where the DC output enters the PV Inverter and is finally inverted into AC power to feed the physical grid, visually presenting a full-stack testing solution for grid-tied PV inverters.


Production Line Burn-in and End-of-Line Testing

For production burn-in and end-of-line testing, CORTEX provides a high-density programmable source/load platform for power modules, DC/DC converters, OBCs, inverters, and other DC power products. Its regenerative load operation helps reduce facility heat load and energy waste during long-duration testing. With rackmount integration, parallel expansion, and cabinet-level power scaling, CORTEX can be configured into automated test systems for high-throughput production validation.

Applicable testing standards, dependent on specifications and configurations:

  • IEC 61010-1:2010+A1:2016:safety requirements for measurement, control, and laboratory equipment
  • IEC 61326-1:2020:EMC requirements for measurement, control, and laboratory equipment
  • IEC 61000-4-29:2000:DC voltage dips and interruptions immunity
  • DUT-specific standards such as ISO 16750-2, IEC 62477-1, IEC 61851, IEC 62891, depending on the product under test

Specifications

The following specifications are subject to modifications and changes without notification in advance. All specifications measured are at product's maximum ratings, if not otherwise noted.

MODEL: 40V/60V/80V

AC INPUT

Voltage Range304Vac-480Vac/380V±20%
Frequency (Hz) 47-63Hz
Wiring Mode 3ph+PE
Power Factor 0.99 @ full load
Efficiency 93.5%

PROTECTIVE FUNCTIONS

Over-Voltage Protection Adjustable 0-110% U-Nominal(+1% F.S.)
Over-Current Protection Adjustable 0-110% I-Nominal(+1% F.S.)
Over-Power Protection Adjustable 0-110% P-Nominal(+1% F.S.)
Over-Temperature Protection

VOLTAGE

Programming Accuracy ±0.002% F.S.
Programming Resolution ±1mV
Display Accuracy ±0.002% F.S.
Line Regulation CV ±0.01%FS. (208V-480VAC+10%input voltage, constant load and constant temperature)
Load Regulation CV ±0.01%FS. (0-100% load, constant load and constant temperature)
Ripple (rms) CV <25mV
Ripple and Noise p-p CV <300mVpp
Remote Compensation max. Voltage ±1V
Rise Time 10%-90% CV 1ms
Full Time 90%-10% CV 1ms
Voltage Swing Rate 150V/ms
Recovery Time Recovery to steady state within 2.5ms±0.75% F.S. (25%-50% or 50%-25%) load
Discharge Time ≤20s

BATTERY SIMULATION

Battery Type Lithium manganate, lithium Cobaltate, lithium iron phosphate, Nickel-metal hydride, Ternary lithium, lithium titanate and lead-acid batteries
Setting Parameters
  • Parameters such as number of series connections,numberofparalel connections
  • Initial SOC,initial temperature,internal resistance, single unit capacity
Interface Support for CSV custom model import
Real-Time 200μs command update rate

Environment

Operating Temperature 0 to50(°C) (power derating over 35°C)
Storage Temperature -20 to 70(°C)
Humidity ≤80%. Not condensing
Altitude Output current derating 2%/100m above 2000m or Ta derating 1°C/100m

Insulation

Negative-PE ±500 VDC
Positive-PE +500 VDC
AC Input-PE 2.5kVAC

Other

Dimension 435*132*781mm
Weight 40kg

CURRENT

Programming Accuracy +0.15% F.S.
Programming Resolution +100mA
Display Accuracy +0.15% F.S.
Display Resolution +10mA
Line Regulation CC ±0.01%FS. (208V-480VAC+10% input voltage, constant load and constant temperature)
Load Regulation CC ±0.05%FS. (0-100% load, constant load and constant temperature)
Rise Time 10%-90% CC 1ms
Full Time 90%-10% CC 1ms

POWER

Programming Accuracy +30W
Programming Resolution +10W
Display Accuracy +30W
Display Resolution +10W

RESISTANCE

Range 0.003-100Ω
Programming Accuracy 1mΩ
Programming Resolution 1mΩ

SAS

Short-Circuit Current Setting Range 0A~le
Simulated Fill Factor Range 0.3~0.95
Photovoltaic Panel Type Selection C-Si, Thin-film, Custom
I-V Curve Update Rate Typically 1ms, with online curve switching function
I-V Curve Criteria EN50530, Sandia, simple
I-V Curve Function Static curves; curve scanning; static sequences; static MPPT; dynamic MPPT;weather simulation; Shading of photovoltaic panels; curve programming; custom curves etc.
Curve Setting
  • I-V Curves can be customized with parameters such as Voc, Isc, FF and Pm
  • Dynamic working mode takes into account environmental influences such as temperature changes and irradiance, and can continuously output I-V curves for different environments
  • Built-in EN50530, Sandia dynamic I-V curve test program

PROGRAMMING

Programming Mode Live, Wave, Step, Advanced
Programming Steps 200
Cycle Range 0~9999999 times
Minimum Programming Cycle 100μs
Mode of Operation Load, end, trigger

Interfaces/Any Port

Functions and Definitions See "Any port interface specification"
Isolation 707VDC

Interfaces

Rear Panel
  • Type-B, USB, LAN, Share Bus, Magic-BUS, Magic-BOX
  • DC terminal, AC supply, Remote sensing, Analog interface
  • Isolation 707VDC
    MODEL: 200V/360V

    AC INPUT

    Voltage Range 304Vac-480Vac/380V±20%
    Frequency (Hz) 47-63Hz
    Wiring Mode 3ph+PE
    Power Factor 0.99 @ full load
    Efficiency 94%

    PROTECTIVE FUNCTIONS

    Over-Voltage Protection Adjustable 0-110% U-Nominal(+1% F.S.)
    Over-Current Protection Adjustable 0-110% I-Nominal(+1% F.S.)
    Over-Power Protection Adjustable 0-110% P-Nominal(+1% F.S.)
    Over-Temperature Protection

    VOLTAGE

    Programming Accuracy ±0.002% F.S.
    Programming Resolution ±10mV
    Display Accuracy ±0.002% F.S.
    Line Regulation CV ±0.01%FS. (208V-480VAC+10%input voltage, constant load and constant temperature)
    Load Regulation CV ±0.01%FS. (0-100% load, constant load and constant temperature)
    Ripple (rms) CV <60mV
    Ripple and Noise p-p CV <480mVpp
    Remote Compensation max. Voltage ±1V
    Rise Time 10%-90% CV 1ms
    Full Time 90%-10% CV 1ms
    Voltage Swing Rate 200V/ms
    Recovery Time Recovery to steady state within 2.5ms±0.75% F.S. (25%-50% or 50%-25%) load
    Discharge Time ≤20s

    BATTERY SIMULATION

    Battery Type Lithium manganate, lithium Cobaltate, lithium iron phosphate, Nickel-metal hydride, Ternary lithium, lithium titanate and lead-acid batteries
    Setting Parameters
    • Parameters such as number of series connections,numberofparalel connections
    • Initial SOC,initial temperature,internal resistance, single unit capacity
    Interface Support for CSV custom model import
    Real-Time 200μs command update rate

    Environment

    Operating Temperature 0 to50(°C) (power derating over 35°C)
    Storage Temperature -20 to 70(°C)
    Humidity ≤80%. Not condensing
    Altitude Output current derating 2%/100m above 2000m or Ta derating 1°C/100m

    Insulation

    Negative-PE ±1500 VDC
    Positive-PE +1500 VDC
    AC Input-PE 2.5kVAC

    Other

    Dimension 435*132*781mm
    Weight 35kg

    CURRENT

    Programming Accuracy +0.02% F.S.
    Programming Resolution +10mA
    Display Accuracy +0.02% F.S.
    Display Resolution +1mA
    Line Regulation CC ±0.01%FS. (208V-480VAC+10% input voltage, constant load and constant temperature)
    Load Regulation CC ±0.05%FS. (0-100% load, constant load and constant temperature)
    Rise Time 10%-90% CC 500μs
    Full Time 90%-10% CC500μs

    POWER

    Programming Accuracy +3W
    Programming Resolution +1W
    Display Accuracy +3W
    Display Resolution +1W

    RESISTANCE

    Range 0.05-100Ω
    Programming Accuracy 0.01Ω
    Programming Resolution 0.01Ω

    SAS

    Short-Circuit Current Setting Range 0A~le
    Simulated Fill Factor Range 0.3~0.95
    Photovoltaic Panel Type Selection C-Si, Thin-film, Custom
    I-V Curve Update Rate Typically 1ms, with online curve switching function
    I-V Curve Criteria EN50530, Sandia, simple
    I-V Curve Function Static curves; curve scanning; static sequences; static MPPT; dynamic MPPT;weather simulation; Shading of photovoltaic panels; curve programming; custom curves etc.
    Curve Setting
    • I-V Curves can be customized with parameters such as Voc, Isc, FF and Pm
    • Dynamic working mode takes into account environmental influences such as temperature changes and irradiance, and can continuously output I-V curves for different environments
    • Built-in EN50530, Sandia dynamic I-V curve test program

    PROGRAMMING

    Programming Mode Live, Wave, Step, Advanced
    Programming Steps 200
    Cycle Range 0~9999999 times
    Minimum Programming Cycle 100μs
    Mode of Operation Load, end, trigger

    Interfaces/Any Port

    Functions and Definitions See "Any port interface specification"
    Isolation 707VDC

    Interfaces

    Rear Panel
  • Type-B, USB, LAN, Share Bus, Magic-BUS, Magic-BOX
  • DC terminal, AC supply, Remote sensing, Analog interface
  • Isolation 707VDC
    MODEL: 500V/600V

    AC INPUT

    Voltage Range 304Vac-480Vac/380V±20%
    Frequency (Hz) 47-63Hz
    Wiring Mode 3ph+PE
    Power Factor 0.99 @ full load
    Efficiency 95%

    PROTECTIVE FUNCTIONS

    Over-Voltage Protection Adjustable 0-110% U-Nominal(+1% F.S.)
    Over-Current Protection Adjustable 0-110% I-Nominal(+1% F.S.)
    Over-Power Protection Adjustable 0-110% P-Nominal(+1% F.S.)
    Over-Temperature Protection

    VOLTAGE

    Programming Accuracy ±0.002% F.S.
    Programming Resolution ±10mV
    Display Accuracy ±0.002% F.S.
    Line Regulation CV ±0.01%FS. (208V-480VAC+10%input voltage, constant load and constant temperature)
    Load Regulation CV ±0.01%FS. (0-100% load, constant load and constant temperature)
    Ripple (rms) CV <200mV
    Ripple and Noise p-p CV <1000mVpp
    Remote Compensation max. Voltage ±1V
    Rise Time 10%-90% CV 1ms
    Full Time 90%-10% CV 1ms
    Voltage Swing Rate 1500V/ms
    Recovery Time Recovery to steady state within 2.5ms±0.75% F.S. (25%-50% or 50%-25%) load
    Discharge Time ≤30s

    BATTERY SIMULATION

    Battery Type Lithium manganate, lithium Cobaltate, lithium iron phosphate, Nickel-metal hydride, Ternary lithium, lithium titanate and lead-acid batteries
    Setting Parameters
    • Parameters such as number of series connections,numberofparalel connections
    • Initial SOC,initial temperature,internal resistance, single unit capacity
    Interface Support for CSV custom model import
    Real-Time 200μs command update rate

    Environment

    Operating Temperature 0 to50(°C) (power derating over 35°C)
    Storage Temperature -20 to 70(°C)
    Humidity ≤80%. Not condensing
    Altitude Output current derating 2%/100m above 2000m or Ta derating 1°C/100m

    Insulation

    Negative-PE ±1500 VDC
    Positive-PE +2000 VDC
    AC Input-PE 2.5kVAC

    Other

    Dimension 435*132*781mm
    Weight 35kg

    CURRENT

    Programming Accuracy +0.02% F.S.
    Programming Resolution +10mA
    Display Accuracy +0.02% F.S.
    Display Resolution +1mA
    Line Regulation CC ±0.01%FS. (208V-480VAC+10% input voltage, constant load and constant temperature)
    Load Regulation CC ±0.05%FS. (0-100% load, constant load and constant temperature)
    Rise Time 10%-90% CC 500μs
    Full Time 90%-10% CC500μs

    POWER

    Programming Accuracy +3W
    Programming Resolution +1W
    Display Accuracy +3W
    Display Resolution +1W

    RESISTANCE

    Range 0.05-3000Ω
    Programming Accuracy 0.01Ω
    Programming Resolution 0.01Ω

    SAS

    Short-Circuit Current Setting Range 0A~le
    Simulated Fill Factor Range 0.3~0.95
    Photovoltaic Panel Type Selection C-Si, Thin-film, Custom
    I-V Curve Update Rate Typically 1ms, with online curve switching function
    I-V Curve Criteria EN50530, Sandia, simple
    I-V Curve Function Static curves; curve scanning; static sequences; static MPPT; dynamic MPPT;weather simulation; Shading of photovoltaic panels; curve programming; custom curves etc.
    Curve Setting
    • I-V Curves can be customized with parameters such as Voc, Isc, FF and Pm
    • Dynamic working mode takes into account environmental influences such as temperature changes and irradiance, and can continuously output I-V curves for different environments
    • Built-in EN50530, Sandia dynamic I-V curve test program

    PROGRAMMING

    Programming Mode Live, Wave, Step, Advanced
    Programming Steps 200
    Cycle Range 0~9999999 times
    Minimum Programming Cycle 100μs
    Mode of Operation Load, end, trigger

    Interfaces/Any Port

    Functions and Definitions See "Any port interface specification"
    Isolation 707VDC

    Interfaces

    Rear Panel
  • Type-B, USB, LAN, Share Bus, Magic-BUS, Magic-BOX
  • DC terminal, AC supply, Remote sensing, Analog interface
  • Isolation 707VDC
    MODEL: 800V/1000V

    AC INPUT

    Voltage Range 304Vac-480Vac/380V±20%
    Frequency (Hz) 47-63Hz
    Wiring Mode 3ph+PE
    Power Factor 0.99 @ full load
    Efficiency 94%

    PROTECTIVE FUNCTIONS

    Over-Voltage Protection Adjustable 0-110% U-Nominal(+1% F.S.)
    Over-Current Protection Adjustable 0-110% I-Nominal(+1% F.S.)
    Over-Power Protection Adjustable 0-110% P-Nominal(+1% F.S.)
    Over-Temperature Protection

    VOLTAGE

    Programming Accuracy ±0.002% F.S.
    Programming Resolution ±10mV
    Display Accuracy ±0.002% F.S.
    Line Regulation CV ±0.01%FS. (208V-480VAC+10%input voltage, constant load and constant temperature)
    Load Regulation CV ±0.01%FS. (0-100% load, constant load and constant temperature)
    Ripple (rms) CV <200mV
    Ripple and Noise p-p CV <1200mVpp
    Remote Compensation max. Voltage ±1V
    Rise Time 10%-90% CV 1ms
    Full Time 90%-10% CV 1ms
    Voltage Swing Rate 600V/ms
    Recovery Time Recovery to steady state within 2.5ms±0.75% F.S. (25%-50% or 50%-25%) load
    Discharge Time ≤20s

    BATTERY SIMULATION

    Battery Type Lithium manganate, lithium Cobaltate, lithium iron phosphate, Nickel-metal hydride, Ternary lithium, lithium titanate and lead-acid batteries
    Setting Parameters
    • Parameters such as number of series connections,numberofparalel connections
    • Initial SOC,initial temperature,internal resistance, single unit capacity
    Interface Support for CSV custom model import
    Real-Time 200μs command update rate

    Environment

    Operating Temperature 0 to50(°C) (power derating over 35°C)
    Storage Temperature -20 to 70(°C)
    Humidity ≤80%. Not condensing
    Altitude Output current derating 2%/100m above 2000m or Ta derating 1°C/100m

    Insulation

    Negative-PE ±1500 VDC
    Positive-PE +1500 VDC
    AC Input-PE 2.5kVAC

    Other

    Dimension 435*132*781mm
    Weight 35kg

    CURRENT

    Programming Accuracy +0.02% F.S.
    Programming Resolution +10mA
    Display Accuracy +0.02% F.S.
    Display Resolution +1mA
    Line Regulation CC ±0.01%FS. (208V-480VAC+10% input voltage, constant load and constant temperature)
    Load Regulation CC ±0.05%FS. (0-100% load, constant load and constant temperature)
    Rise Time 10%-90% CC 500μs
    Full Time 90%-10% CC500μs

    POWER

    Programming Accuracy +3W
    Programming Resolution +1W
    Display Accuracy +3W
    Display Resolution +1W

    RESISTANCE

    Range 0.05-1000Ω
    Programming Accuracy 0.01Ω
    Programming Resolution 0.01Ω

    SAS

    Short-Circuit Current Setting Range 0A~le
    Simulated Fill Factor Range 0.3~0.95
    Photovoltaic Panel Type Selection C-Si, Thin-film, Custom
    I-V Curve Update Rate Typically 1ms, with online curve switching function
    I-V Curve Criteria EN50530, Sandia, simple
    I-V Curve Function Static curves; curve scanning; static sequences; static MPPT; dynamic MPPT;weather simulation; Shading of photovoltaic panels; curve programming; custom curves etc.
    Curve Setting
    • I-V Curves can be customized with parameters such as Voc, Isc, FF and Pm
    • Dynamic working mode takes into account environmental influences such as temperature changes and irradiance, and can continuously output I-V curves for different environments
    • Built-in EN50530, Sandia dynamic I-V curve test program

    PROGRAMMING

    Programming Mode Live, Wave, Step, Advanced
    Programming Steps 200
    Cycle Range 0~9999999 times
    Minimum Programming Cycle 100μs
    Mode of Operation Load, end, trigger

    Interfaces/Any Port

    Functions and Definitions See "Any port interface specification"
    Isolation 707VDC

    Interfaces

    Rear Panel
  • Type-B, USB, LAN, Share Bus, Magic-BUS, Magic-BOX
  • DC terminal, AC supply, Remote sensing, Analog interface
  • Isolation 707VDC
    MODEL: 1500V/2000V

    AC INPUT

    Voltage Range 304Vac-480Vac/380V±20%
    Frequency (Hz) 47-63Hz
    Wiring Mode 3ph+PE
    Power Factor 0.99 @ full load
    Efficiency 95%

    PROTECTIVE FUNCTIONS

    Over-Voltage Protection Adjustable 0-110% U-Nominal(+1% F.S.)
    Over-Current Protection Adjustable 0-110% I-Nominal(+1% F.S.)
    Over-Power Protection Adjustable 0-110% P-Nominal(+1% F.S.)
    Over-Temperature Protection

    VOLTAGE

    Programming Accuracy ±0.002% F.S.
    Programming Resolution ±10mV
    Display Accuracy ±0.002% F.S.
    Line Regulation CV ±0.01%FS. (208V-480VAC+10%input voltage, constant load and constant temperature)
    Load Regulation CV ±0.01%FS. (0-100% load, constant load and constant temperature)
    Ripple (rms) CV <400mV
    Ripple and Noise p-p CV <2400mVpp
    Remote Compensation max. Voltage ±1V
    Rise Time 10%-90% CV 1ms
    Full Time 90%-10% CV 1ms
    Voltage Swing Rate 5000V/ms
    Recovery Time Recovery to steady state within 2.5ms±0.75% F.S. (25%-50% or 50%-25%) load
    Discharge Time ≤30s

    BATTERY SIMULATION

    Battery Type Lithium manganate, lithium Cobaltate, lithium iron phosphate, Nickel-metal hydride, Ternary lithium, lithium titanate and lead-acid batteries
    Setting Parameters
    • Parameters such as number of series connections,numberofparalel connections
    • Initial SOC,initial temperature,internal resistance, single unit capacity
    Interface Support for CSV custom model import
    Real-Time 200μs command update rate

    Environment

    Operating Temperature 0 to50(°C) (power derating over 35°C)
    Storage Temperature -20 to 70(°C)
    Humidity ≤80%. Not condensing
    Altitude Output current derating 2%/100m above 2000m or Ta derating 1°C/100m

    Insulation

    Negative-PE ±1500 VDC
    Positive-PE +2000 VDC
    AC Input-PE 2.5kVAC

    Other

    Dimension 435*132*781mm
    Weight 35kg

    CURRENT

    Programming Accuracy +0.02% F.S.
    Programming Resolution +10mA
    Display Accuracy +0.02% F.S.
    Display Resolution +1mA
    Line Regulation CC ±0.01%FS. (208V-480VAC+10% input voltage, constant load and constant temperature)
    Load Regulation CC ±0.05%FS. (0-100% load, constant load and constant temperature)
    Rise Time 10%-90% CC 500μs
    Full Time 90%-10% CC500μs

    POWER

    Programming Accuracy +3W
    Programming Resolution +1W
    Display Accuracy +3W
    Display Resolution +1W

    RESISTANCE

    Range 0.05-3000Ω
    Programming Accuracy 0.1Ω
    Programming Resolution 0.1Ω

    SAS

    Short-Circuit Current Setting Range 0A~le
    Simulated Fill Factor Range 0.3~0.95
    Photovoltaic Panel Type Selection C-Si, Thin-film, Custom
    I-V Curve Update Rate Typically 1ms, with online curve switching function
    I-V Curve Criteria EN50530, Sandia, simple
    I-V Curve Function Static curves; curve scanning; static sequences; static MPPT; dynamic MPPT;weather simulation; Shading of photovoltaic panels; curve programming; custom curves etc.
    Curve Setting
    • I-V Curves can be customized with parameters such as Voc, Isc, FF and Pm
    • Dynamic working mode takes into account environmental influences such as temperature changes and irradiance, and can continuously output I-V curves for different environments
    • Built-in EN50530, Sandia dynamic I-V curve test program

    PROGRAMMING

    Programming Mode Live, Wave, Step, Advanced
    Programming Steps 200
    Cycle Range 0~9999999 times
    Minimum Programming Cycle 100μs
    Mode of Operation Load, end, trigger

    Interfaces/Any Port

    Functions and Definitions See "Any port interface specification"
    Isolation 707VDC

    Interfaces

    Rear Panel
  • Type-B, USB, LAN, Share Bus, Magic-BUS, Magic-BOX
  • DC terminal, AC supply, Remote sensing, Analog interface
  • Isolation 707VDC
    the benefits of bidirectional power supply

    Prioritize Bidirectional Power Supply for Your Testing


    Bidirectional power supply integrates power source and electronic load in one unit to save your testing and equipment ownership cost as well as for improved space utilization.

    Read the Article

    Access our Download Center and Find Out Related Data Sheets

    From detailed integration manuals to the latest firmware, our Download Center provides the technical depth required for high-precision power electronics development. Enhance your ActionPower systems today.

    Access Download Center

    GET YOUR BIDIRECTIONAL DC POWER SUPPLY

    Global Contact

    Sales Network & Locations

    If you are looking for an automated test system to validate your products during development and research stages to make sure of their successful commercial launch, ACTIONPOWER will be at your disposal to study your specifications and requirements to provided either standard or customized testing solutions.

    Join Our Network as a Distributor?

    Interested in ACTIONPOWER's testing solutions and equipment and want to promote them in your market? Contact us to joint our global sales network to grow together as partners.

    Quick Model Access

    Smart Discovery

    Access our Power Supply Wizard to find the right programmable power supply for your use cases and testing scenarios.

    discover programmable power supply by filtering with current, voltage and power ranges
    CONTACT US

    Contact Us

    Professionalism is what we care about. Why not email us with your technical requirements fully explained rather than submitting a simple message so that we revert more proactively with detailed solutions?

    Subscribe to Newsletter

    Thank you for subscribing!