ZETA SERIES
Laboratory DC Power Supply
Ultimate precision DC Power Supply for research and development
The ZETA series is a high-precision, rack-mountable (1U height, 5kW capacity) programmable DC power supply designed for industrial, laboratory, and OEM applications. It delivers wide-range outputs up to 2000V/200A with exceptional ±0.02% F.S. voltage accuracy and ±10ppm/8hr current stability, eliminating the need for separate precision meters. Key innovations include auto master-slave parallel/series operation (scalable to 99 units), 1ms-resolution waveform programming, and four operational modes (CV/CC/CVCP/CCCP). Its programmable output impedance (0-100Ω) simulates cable resistance or battery behaviour, while industrial-grade controls (full-touch panel, dual knobs) ensure seamless operation in particle accelerators, medical systems, and ATE integration. Highlighted Features
- Compact Footprint: 1U chassis (5kW capacity) with 2000V/200A range
- Ultra Precision & Stability:Voltage accuracy: ±0.02% F.S.; Current stability: ±10ppm/8hr (lab conditions) Resolution<5ppm
- Analogue programming: 5V/10V control via REMOTE port for PLC/ATE systems
- Auto master-slave: Parallel (up to 99 units) or series operation for bipolar outputs
- Multi-Mode Operation: CV (Constant Voltage), CC (Constant Current), CVCP (Constant Voltage/Power), CCCP (Constant Current/Power)
- Programmable Output Impedance: Adjustable 0-100Ω to simulate cable drops or battery characteristics
- Industrial Design: Full-touch interface, dual-encoder knobs, automotive-grade keys

Model Options
Find the right specification for your requirements
| Model | Power (kVA) | Voltage Range (V) | Current Range (A) | Voltage Ripple RMS (mV) (5Hz-1MHz) | Rise Time (ms) (Programmed Response) | Fall Time @ Full Load (ms) (Programmed Response) | Current Ripple RMS @ Rated Voltage (mA) | Input Voltage (V) |
|---|---|---|---|---|---|---|---|---|
| ZD1.7-020 | 1.7 | 0~20 | 0~200 | 10 | 30 | 50 | 300 | 220 |
| ZD1.7-040 | 1.7 | 0~40 | 0~125 | 12 | 30 | 80 | 75 | 220 |
| ZD1.7-060 | 1.7 | 0~60 | 0~85 | 12 | 50 | 80 | 50 | 220 |
| ZD1.7-100 | 1.7 | 0~100 | 0~50 | 15 | 50 | 100 | 23 | 220 |
| ZD1.7-150 | 1.7 | 0~150 | 0~34 | 20 | 50 | 100 | 23 | 220 |
| ZD1.7-350 | 1.7 | 0~350 | 0~15 | 60 | 50 | 100 | 7.5 | 220 |
| ZD1.7-750 | 1.7 | 0~750 | 0~7 | 100 | 100 | 200 | 4 | 220 |
| ZD3.0-020 | 3 | 0~20 | 0~200 | 10 | 30 | 50 | 300 | 220 |
| ZD3.0-030 | 3 | 0~30 | 0~170 | 12 | 30 | 80 | 150 | 220 |
| ZD3.0-040 | 3 | 0~40 | 0~125 | 12 | 30 | 80 | 75 | 220 |
| ZD3.0-060 | 3 | 0~60 | 0~85 | 12 | 50 | 80 | 50 | 220 |
| ZD3.0-100 | 3 | 0~100 | 0~50 | 15 | 50 | 100 | 23 | 220 |
| ZD3.0-150 | 3 | 0~150 | 0~34 | 20 | 50 | 100 | 23 | 220 |
| ZD3.0-350 | 3 | 0~350 | 0~15 | 60 | 50 | 100 | 7.5 | 220 |
| ZD3.0-750 | 3 | 0~750 | 0~7 | 100 | 100 | 200 | 4 | 220 |
| ZD3.0-2K0 | 3 | 0~2000 | 0~1.5 | 300 | 100 | 200 | 4 | 220 |
| ZD3.0-020H | 3 | 0~20 | 0~200 | 10 | 30 | 50 | 300 | 220 |
| ZD3.0-040H | 3 | 0~40 | 0~125 | 12 | 30 | 80 | 75 | 220 |
| ZD3.6-020 | 3.6 | 0~20 | 0~200 | 10 | 30 | 50 | 300 | 380 |
| ZD3.6-030 | 3.6 | 0~30 | 0~170 | 12 | 30 | 80 | 150 | 380 |
| ZD3.6-040 | 3.6 | 0~40 | 0~125 | 12 | 30 | 80 | 75 | 380 |
| ZD3.6-060 | 3.6 | 0~60 | 0~85 | 12 | 50 | 80 | 50 | 380 |
| ZD3.6-100 | 3.6 | 0~100 | 0~50 | 15 | 50 | 100 | 23 | 380 |
| ZD3.6-150 | 3.6 | 0~150 | 0~34 | 20 | 50 | 100 | 23 | 380 |
| ZD3.6-350 | 3.6 | 0~350 | 0~15 | 60 | 50 | 100 | 7.5 | 380 |
| ZD3.6-750 | 3.6 | 0~750 | 0~7 | 100 | 100 | 200 | 4 | 380 |
| ZD5.0-030 | 5 | 0~30 | 0~170 | 12 | 30 | 80 | 150 | 380 |
| ZD5.0-100 | 5 | 0~100 | 0~50 | 15 | 50 | 100 | 23 | 380 |
| ZD5.0-150 | 5 | 0~150 | 0~34 | 20 | 50 | 100 | 23 | 380 |
| ZD5.0-350 | 5 | 0~350 | 0~15 | 60 | 50 | 100 | 7.5 | 380 |
| ZD5.0-750 | 5 | 0~750 | 0~7 | 100 | 100 | 200 | 4 | 380 |
Highlighted Features
Discover the ultimate precision of ZETA DC Programmable Power Source
High Stability Performance

Ultimate Precision
The ZETA series integrates an independent high-precision voltage and current measurement system, delivering output voltage accuracy up to ±0.02% F.S. (Full Scale).

Automatic Master-Slave Series/Parallel Operation
The system features intelligent master-slave auto-selection and seamless parallel operation, supporting multi-unit synchronization. The master unit handles programming, testing, and reporting total current, while the entire cluster behaves as a single unified power source.

Advanced Programmable Control & Waveform Generation
The ZETA series integrates isolated analog control (5V/10V via REMOTE port) with high-speed waveform programming (1ms resolution). It supports 200-step sequences (10 stored profiles) and 999-step waveforms for complex testing. The system provides real-time voltage/current monitoring for easy PLC/ATE integration, combining precision analog adjustment with digital waveform flexibility in one unit—ideal for automated testing, stress cycling, and real-world power simulation.

Applications
Take advantage of ZETA's ultimate precision to accelerate your research and development
MEDICAL ACCELERATORThe ZETA power supply's ±10ppm current stability and <5ppm resolution ensure precise beam current control for proton therapy and linear accelerators, meeting the ultra-high stability requirements of medical equipment. Its low ripple output (<10mV RMS) minimizes electromagnetic interference, safeguarding signal integrity for sensitive medical imaging systems.
Find SolutionsIn synchrotron radiation and ion acceleration experiments, ZETA's master-slave parallel operation (supports cascading up to 99 units) and 0.02% voltage accuracy deliver ultra-consistent DC power for magnet power supplies. The 1ms waveform programming capability simulates complex acceleration field variations, supporting advanced high-energy physics research.
Find SolutionsWith a wide voltage range (0-2000V) and programmable output impedance (0-100Ω), the ZETA precisely simulates bus voltage fluctuations and cable losses in satellite power systems. Its CVCP/CCCP modes enable constant-power testing, critical for spacecraft power conversion efficiency validation.
Find SolutionsUsing List mode to preset 200-step temperature-voltage stress profiles, combined with ±0.02% accuracy, the ZETA delivers long-term stable power for chip aging tests. Its daisy-chain control simplifies multi-station burn-in system integration.
Specifications
The following specifications are subject to modifications and changes without notification in advance. All specifications measured are at product's maximum ratings, if not otherwise noted.
INPUT PARAMETERS
| Maximum Input Current at 100% Load | 15A@220Vac |
|---|---|
| 9.2A@380Vac | |
| Input Voltage/Frequency | 220V Model: 185~265Vac; 47~63Hz |
| 380V Model: 304~460Vac; 47~63Hz | |
| Inrush Current | 30A@220Vac |
| 15A@380Vac | |
| Power Factor (Typical) | 0.97 |
| Efficiency (%) | 91@20V~350V Model |
| 92@350V~2000V Model |
CONSTANT VOLTAGE MODE
| Programming Accuracy | ±0.02% of rated voltage |
|---|---|
| Display Accuracy | ±0.02% of rated voltage |
| Source Regulation | ±0.01% of rated voltage |
| Load Regulation | 0.01% of rated output voltage |
| Temperature Coefficient | 20PPM/°C of rated output voltage (after 30 minutes of power-on). |
| Transient Response Time | When the load current changes between 10% to 90% of the rated output current, the time required for the output voltage to recover to within 0.5% of the rated output voltage: |
CONSTANT CURRENT MODE
| Programming Accuracy | ±0.1% of rated current (Standard) |
|---|---|
| ±0.05% of rated current (High-Performance Version) | |
| Display Accuracy | ±0.1% of rated current (Standard) |
| ±0.05% of rated current (High-Performance Version) | |
| Source Regulation | ±0.01% of rated current |
| Load Regulation | ±0.1% of rated output current (Standard) |
| ±0.05% of rated output current (High-Performance Version) | |
| Temperature Coefficient | 20PPM/°C of rated output current (Standard) |
| 5PPM/°C of rated output current (High-Performance Version) (after 30 minutes of power-on) |
CONSTANT POWER MODE
| Programming Accuracy | ±0.1% of rated current (Standard) |
|---|---|
| Programming Resolution | 0.1W |
| Programming Accuracy | ±0.1% of rated power |
| Display Resolution | 1W |
| Display Accuracy | ±0.1% of rated power |
INTERNAL RESISTANCE MODE
| Rated Impedance | ±0.1% of rated current (Standard) |
|---|---|
| Setting Resolution | 0.1mΩ |
| Setting Accuracy | ±1% of rated impedance |
PROGRAMMING MODE
| Programming Steps | 200 steps |
|---|---|
| Cycle Count | 999,999 |
| Minimum Programming Step Time | 1ms |
| Operation Modes | Load, End, Trigger |
| Supported Modes | List, Wave |
ANALOGUE PROGRAMMING & MONITORING (ISOLATED FROM OUTPUT)
| Voltage Programming of Voltage Output | Range: 0~100% (0~5V or 0~10V, user-selectable) |
|---|---|
| Accuracy & Linearity: ±0.1% of rated output voltage | |
| Voltage Programming of Current Output | Range: 0~100% (0~5V or 0~10V, user-selectable) |
| Accuracy & Linearity: ±0.1% of rated output voltage | |
| Resistance Programming of Voltage Output | Range: 0~100% (0~5/10 kΩ full scale, user-selectable) |
| Accuracy & Linearity: ±0.5% of rated output voltage | |
| Resistance Programming of Current Output | Range: 0~100% (0~5/10 kΩ full scale, user-selectable) |
| Accuracy & Linearity: ±0.5% of rated output voltage | |
| Output Voltage Monitoring | Range: 0~5V or 0~10V (user-selectable) |
| Accuracy: ±0.1% F.S. | |
| Output Current Monitoring | Range: 0~5V or 0~10V (user-selectable) |
| Accuracy: ±0.1% F.S. |
SIGNALS & CONTROLS (ISOLATED FROM OUTPUT)
| Voltage Programming of Voltage Output | Range: 0~100% (0~5V or 0~10V, user-selectable) |
|---|---|
| Output Monitoring: Open-collector | |
| Output ON: Conducting | |
| Output OFF: Open | |
| Max Voltage: 30V | |
| Max Current: 10mA | |
| CV/CC Signal | Monitoring: Open-collector |
| CC Mode: Conducting | |
| CV Mode: Open | |
| Max Voltage: 30V | |
| Max Current: 10mA | |
| CV/CC Signal | Enable/Disable via Electrical Signal or Dry Contact |
| External Control: 0~0.6V or Short-Circuit | |
| Local Control: 2~30V or Open-Circuit | |
| LOCAL/REMOTE Status Monitoring | Analogue Control Monitoring Signal: Open-collector |
| External Control: Conducting | |
| Local Control: Open | |
| Max Voltage: 30V | |
| Max Sink Current: 10mA | |
| ENABLE/DISABLE Signal | Enable/Disable PS Output via Electrical Signal or Dry Contact |
| Enable: 0~0.6V or Short-Circuit | |
| Disable: 2~30V or Open-Circuit | |
| User-Selectable Logic | |
| INTERLOCK (ILC) Control | Enable/Disable PS Output via Electrical Signal or Dry Contact |
| Enable: 0~0.6V or Short-Circuit | |
| Disable: 2~30V or Open-Circuit | |
| Programming Signal | Two Open-Drain Programmable Signals |
| Max Voltage: 25V | |
| Max Sink Current: 100mA (Clamped by 27V Zener Diode) | |
| TRIGGER IN/TRIGGER OUT Signal | Max Low-Level Input Voltage = 0.8V |
| Min High-Level Input Voltage = 2.5V | |
| Max High-Level Input = 5V | |
| Rising Edge Trigger: Pulse Width (Tw) ≥ 10μs (Min) | |
| Rise/Fall Time (Tr/Tf) ≤ 1μs (Max) | |
| Minimum Delay Between Pulses: 1ms |
Access our Download Center and Find Out Related Data Sheets
From detailed integration manuals to the latest firmware, our Download Center provides the technical depth required for high-precision power electronics development. Enhance your ActionPower systems today.
INQUIRE FOR LABORATORY DC POWWER SUPPLY

Sales Network & Locations
If you are looking for an automated test system to validate your products during development and research stages to make sure of their successful commercial launch, ACTIONPOWER will be at your disposal to study your specifications and requirements to provided either standard or customized testing solutions.
Join Our Network as a Distributor?
Interested in ACTIONPOWER's testing solutions and equipment and want to promote them in your market? Contact us to joint our global sales network to grow together as partners.
Contact Us
Professionalism is what we care about. Why not email us with your technical requirements fully explained rather than submitting a simple message so that we revert more proactively with detailed solutions?