ATLAS SERIES
DC ELECTRONIC LOAD
Programmable, High-Speed Linear Electronic Load, Ultimate Precision
The ATLAS Series DC Electronic Load combines high precision, fast dynamic performance, and ultra-high power density in a compact modular design. Built to meet the rigorous demands of power supply, battery, and renewable energy testing, the ATLAS Series delivers reliable load simulation with industry-leading accuracy and responsiveness. With scalable architecture, it supports power expansion from 6kW up to 600kW while maintaining consistent performance across single or multi-module systems. It is ideal for applications ranging from automated production lines and R&D labs to aerospace, EV, and medical power testing. Highlighted Features
- Compact 3U modules deliver up to 6kW per unit
- Current response time as fast as 20μs; dynamic mode up to 20kHz
- Measurement accuracy: Voltage accuracy: 0.025% + 0.025% F.S. & Current accuracy: 0.05% + 0.05% F.S.
- Nanosecond-level transients capturing, sampling up to 500kHz
- Real-time sampling rate up to 500kHz, capturing nanosecond-level transients
- CC, CV, CP, CR, and compound modes available for flexible testing
- Configurable for 0–150V, 600V, or 1200V operation
- Pre-programmed multi-step test sequences for complex automated procedures
- Controlled battery/capacitor discharge and instant short-circuit simulation
- Comprehensive protection: OVP, OCP, OPP, OTP, fan fault, reverse alarm, and sensor fault alerts

Model Options
Find the right specification for your requirements
| Model | Power (kW) | Voltage Level (V) | Current Level (A) | Size |
|---|---|---|---|---|
| PCL02-150-200 | 2kW | 150V | 200A | 3U |
| PCL04-150-400 | 4kW | 150V | 400A | 3U |
| PCL06-150-600 | 6kW | 150V | 600A | 3U |
| PCL12-150-1200 | 12kW | 150V | 1200A | 6U |
| PCL18-150-1800 | 18kW | 150V | 1800A | 12U |
| PCL24-150-2400 | 24kW | 150V | 2400A | 12U |
| PCL30-150-2400 | 30kW | 150V | 2400A | 30U |
| PCL36-150-2400 | 36kW | 150V | 2400A | 30U |
| PCL42-150-2400 | 42kW | 150V | 2400A | 30U |
| PCL48-150-2400 | 48kW | 150V | 2400A | 30U |
| PCL54-150-2400 | 54kW | 150V | 2400A | 30U |
| PCL60-150-2400 | 60kW | 150V | 2400A | 30U |
| PCL02-600-160 | 2kW | 600V | 160A | 3U |
| PCL04-600-320 | 4kW | 600V | 320A | 3U |
| PCL06-600-480 | 6kW | 600V | 480A | 3U |
| PCL12-600-960 | 12kW | 600V | 960A | 6U |
| PCL18-600-1440 | 18kW | 600V | 1440A | 12U |
| PCL24-600-1920 | 24kW | 600V | 1920A | 12U |
| PCL30-600-2400 | 30kW | 600V | 2400A | 30U |
| PCL36-600-2400 | 36kW | 600V | 2400A | 30U |
| PCL42-600-2400 | 42kW | 600V | 2400A | 30U |
| PCL48-600-2400 | 48kW | 600V | 2400A | 30U |
| PCL54-600-2400 | 54kW | 600V | 2400A | 30U |
| PCL60-600-2400 | 60kW | 600V | 2400A | 30U |
| PCL02-1200-80 | 2kW | 1200V | 80A | 3U |
| PCL04-1200-160 | 4kW | 1200V | 160A | 3U |
| PCL06-1200-240 | 6kW | 1200V | 240A | 3U |
| PCL12-1200-480 | 12kW | 1200V | 480A | 6U |
| PCL18-1200-720 | 18kW | 1200V | 720A | 12U |
| PCL24-1200-960 | 24kW | 1200V | 960A | 12U |
| PCL30-1200-1200 | 30kW | 1200V | 1200A | 30U |
| PCL36-1200-1440 | 36kW | 1200V | 1440A | 30U |
| PCL42-1200-1680 | 42kW | 1200V | 1680A | 30U |
| PCL48-1200-1920 | 48kW | 1200V | 1920A | 30U |
| PCL54-1200-2160 | 54kW | 1200V | 2160A | 30U |
| PCL60-1200-2400 | 60kW | 1200V | 2400A | 30U |
Model Options
Find the right specification for your requirements
| Model | Power (kW) | Voltage Level (V) | Current Level (A) | Size |
|---|---|---|---|---|
| AD02-150-200 | 2kW | 150V | 200A | 3U |
| AD04-150-400 | 4kW | 150V | 400A | 3U |
| AD06-150-600 | 6kW | 150V | 600A | 3U |
| AD12-150-1200 | 12kW | 150V | 1200A | 6U |
| AD18-150-1800 | 18kW | 150V | 1800A | 12U |
| AD24-150-2400 | 24kW | 150V | 2400A | 12U |
| AD30-150-2400 | 30kW | 150V | 2400A | 30U |
| AD36-150-2400 | 36kW | 150V | 2400A | 30U |
| AD42-150-2400 | 42kW | 150V | 2400A | 30U |
| AD48-150-2400 | 48kW | 150V | 2400A | 30U |
| AD54-150-2400 | 54kW | 150V | 2400A | 30U |
| AD60-150-2400 | 60kW | 150V | 2400A | 30U |
| AD02-600-160 | 2kW | 600V | 160A | 3U |
| AD04-600-320 | 4kW | 600V | 320A | 3U |
| AD06-600-480 | 6kW | 600V | 480A | 3U |
| AD12-600-960 | 12kW | 600V | 960A | 6U |
| AD18-600-1440 | 18kW | 600V | 1440A | 12U |
| AD24-600-1920 | 24kW | 600V | 1920A | 12U |
| AD30-600-2400 | 30kW | 600V | 2400A | 30U |
| AD36-600-2400 | 36kW | 600V | 2400A | 30U |
| AD42-600-2400 | 42kW | 600V | 2400A | 30U |
| AD48-600-2400 | 48kW | 600V | 2400A | 30U |
| AD54-600-2400 | 54kW | 600V | 2400A | 30U |
| AD60-600-2400 | 60kW | 600V | 2400A | 30U |
| AD02-1200-80 | 2kW | 1200V | 80A | 3U |
| AD04-1200-160 | 4kW | 1200V | 160A | 3U |
| AD06-1200-240 | 6kW | 1200V | 240A | 3U |
| AD12-1200-480 | 12kW | 1200V | 480A | 6U |
| AD18-1200-720 | 18kW | 1200V | 720A | 12U |
| AD24-1200-960 | 24kW | 1200V | 960A | 12U |
| AD30-1200-1200 | 30kW | 1200V | 1200A | 30U |
| AD36-1200-1440 | 36kW | 1200V | 1440A | 30U |
| AD42-1200-1680 | 42kW | 1200V | 1680A | 30U |
| AD48-1200-1920 | 48kW | 1200V | 1920A | 30U |
| AD54-1200-2160 | 54kW | 1200V | 2160A | 30U |
| AD60-1200-2400 | 60kW | 1200V | 2400A | 30U |
Highlighted Features
These are what make our power supply different
High Power Density & Scalable Architecture
Compact 3U module design, with a single module delivering up to 6kW of power. Supports multi-module stacking for expansion, featuring master/slave parallel control, enabling a single unit to scale from 6kW to 60kW. The high-speed digital parallel system allows up to 100 units to be connected in parallel, expanding total capacity to 600kW. Performance and precision remain identical whether operating as a single unit or in parallel.

High-Speed Current Response
Featuring an ultra-fast current response of 20μs and 20kHz dynamic mode, the system excels in complex testing environments. It enables rapid matching in high-intensity, fast-paced production line testing, significantly improving efficiency.

Ultra-High Measurement Accuracy
With industry-leading precision of 0.025%+0.025% F.S. for voltage and 0.05%+0.05% F.S. for current, the system is ideal for high-accuracy applications such as precision power calibration and medical equipment power supply testing. This ensures authoritative and traceable test data for critical scenarios.

High-Speed Voltage/Current Sampling
With a real-time sampling rate up to 500kHz, the system precisely captures nanosecond-level transient waveforms (including DC-DC power supply switching noise and lithium battery pulse charge/discharge characteristics). This capability provides high-resolution data support for dynamic performance analysis and fault diagnosis.

High-Speed Dynamic & Sweep Modes
Featuring 30kHz rapid load switching capability, the system accurately simulates fast-changing load conditions (such as new energy vehicle motor controller dynamic response tests). The dynamic sweep mode automatically scans through all load parameters without omission, significantly accelerating full-operating-condition stability validation of equipment.

MPPT Maximum Power Point Tracking
ATLAS DC Electronic load is equipped with specialized photovoltaic testing capabilities, the optional MPPT function dynamically tracks solar panels' maximum power point, optimizing energy conversion efficiency testing and supporting R&D for PV inverters and energy storage systems.

Special Waveform Current Testing
The optional custom waveform injection (including sine, sawtooth, and triangular waves) enables performance testing under non-steady-state conditions, ideal for specialized applications such as renewable energy grid-tied equipment and aerospace power system validation.

Flexible Connectivity Options
Supporting LAN, RS232, and CAN FD communication interfaces with optional GPIB connectivity, the system enables seamless test system integration and expansion to accommodate diverse application scenarios.

DC Electronic Loads with Ultimate Precision for Testing
High precision, nanosecond level response, high voltage capability for various industry testing
ENERGY STORAGE SYSTEMVerifies charge/discharge cycles and evaluates battery pack performance under simulated real-world conditions
Find Solutions
ELECTRIC VEHICLE Validation for DC-DC converters, inverters, and UPS systems under dynamic load conditions.
Find Solutions
INDUSTRIAL PRODUCTION EOLEnables high-speed automated testing of power devices in manufacturing with programmable load profiles.
Find Solutions
TROUBLESHOOTING & CALIBRATIONIsolates faults in power components by simulating various load scenarios.
Specifications
The following specifications are subject to modifications and changes without notification in advance.
All specifications measured are at product's maximum ratings, if not otherwise noted.
OPERATION PARAMETERS
| CC Mode | |||
|---|---|---|---|
| Setting Range | @10% of maximum current rating | @50% of maximum current rating | @100% of maximum current rating |
| Resolution | 16 bits | 16 bits | 16 bits |
| Precision | 0.05%+0.05%F.S. | ||
| CV Mode | |||
|---|---|---|---|
| Setting Range | 0~18V | 0-80V | @ 0~150V |
| Resolution | 16 bits | 16 bits | 16 bits |
| Precision | 0.025%+0.025%F.S. | ||
| CR Mode | |||
|---|---|---|---|
| Setting Range | 0.002~20Ω | 0.02~200Ω | 0.2~2000Ω |
| Resolution | 16 bits | 16 bits | 16 bits |
| Precision | Vin/Rset*(0.2%)+0.2%IF.S. | ||
| CP Mode | |||
|---|---|---|---|
| Resolution | 16 bits | ||
| Precision | 0.2%+0.2%F.S. | ||
MEASUREMENT RANGE
| Voltage Readback | |||
|---|---|---|---|
| Setting Range | 0~18V | 0~80V | 0~150V |
| Resolution | 0.1mV | 0.1mV | 0.1mV |
| Precision | 0.02%+0.02%F.S. | ||
| Current Readback | |||
|---|---|---|---|
| Setting Range | Below 100A | Below 1000A | Above 1000V |
| Resolution | 0.1mA | 1mA | 10mA |
| Precision | 0.05%+0.05%F.S. | ||
| Power Readback | |||
|---|---|---|---|
| Setting Range | 0~100%F.S. | ||
| Resolution | 0.01W | ||
| Precision | 0.2%+0.2%F.S. | ||
DYNAMIC MODE
| T1 & T2 | 0.020-100S | ||
|---|---|---|---|
| Resolution | 1μs | ||
| Precision | 1μs+100ppm | ||
| Rise/Fall Slope | 1mA-0.5%F.S./uS | 1mA-2.5%F.S./μS | 10mA-5%F.S./μs |
| Slope Resolution | 0.1mA/μs(below 100A) | 1mA/us(above 100A) | 10mA/μs(above 1000A) |
| Minimum Rise Time | 20μs | ||
| Current Accuracy | 0.2%F.S. | ||
OPERATION PARAMETERS
| CC Mode | |||
|---|---|---|---|
| Setting Range | @10% of maximum current rating | @50% of maximum current rating | @100% of maximum current rating |
| Resolution | 16 bits | 16 bits | 16 bits |
| Precision | 0.05%+0.05%F.S. | ||
| CV Mode | |||
|---|---|---|---|
| Setting Range | 0~80V | 0-150V | @ 0~600V |
| Resolution | 16 bits | 16 bits | 16 bits |
| Precision | 0.025%+0.025%F.S. | ||
| CR Mode | |||
|---|---|---|---|
| Setting Range | 0.02~200Ω | 0.2~2000Ω | 2~20000Ω |
| Resolution | 16 bits | 16 bits | 16 bits |
| Precision | Vin/Rset*(0.2%)+0.2%IF.S. | ||
| CP Mode | |||
|---|---|---|---|
| Setting Range | 0~100%F.S. | ||
| Resolution | 16 bits | ||
| Precision | 0.2%+0.2%F.S. | ||
MEASUREMENT RANGE
| Voltage Readback | |||
|---|---|---|---|
| Setting Range | 0~80V | 0~150V | 0~600V |
| Resolution | 0.1mV | 1mV | 1mV |
| Precision | 0.02%+0.02%F.S. | ||
| Current Readback | |||
|---|---|---|---|
| Setting Range | Below 100A | Below 1000A | Above 1000V |
| Resolution | 0.1mA | 1mA | 10mA |
| Precision | 0.05%+0.05%F.S. | ||
| Power Readback | |||
|---|---|---|---|
| Setting Range | 0~100%F.S. | ||
| Resolution | 0.01W | ||
| Precision | 0.2%+0.2%F.S. | ||
DYNAMIC MODE
| T1 & T2 | 0.020-100S | ||
|---|---|---|---|
| Resolution | 1μs | ||
| Precision | 1μs+100ppm | ||
| Rise/Fall Slope | 1mA-0.5%F.S./uS | 1mA-2.5%F.S./μS | 10mA-5%F.S./μs |
| Slope Resolution | 0.1mA/μs(below 100A) | 1mA/us(above 100A) | 10mA/μs(above 1000A) |
| Minimum Rise Time | 20μs | ||
| Current Accuracy | 0.2%F.S. | ||
OPERATION PARAMETERS
| CC Mode | |||
|---|---|---|---|
| Setting Range | @10% of maximum current rating | @50% of maximum current rating | @100% of maximum current rating |
| Resolution | 16 bits | 16 bits | 16 bits |
| Precision | 0.05%+0.05%F.S. | ||
| CV Mode | |||
|---|---|---|---|
| Setting Range | 0~150V | 0-600V | @ 0~1200V |
| Resolution | 16 bits | 16 bits | 16 bits |
| Precision | 0.025%+0.025%F.S. | ||
| CR Mode | |||
|---|---|---|---|
| Setting Range | 0.04~400Ω | 0.4~4000Ω | 4~40000Ω |
| Resolution | 16 bits | 16 bits | 16 bits |
| Precision | Vin/Rset*(0.2%)+0.2%IF.S. | ||
| CP Mode | |||
|---|---|---|---|
| Setting Range | 0~100%F.S. | ||
| Resolution | 16 bits | ||
| Precision | 0.2%+0.2%F.S. | ||
MEASUREMENT RANGE
| Voltage Readback | |||
|---|---|---|---|
| Setting Range | 0~150V | 0~600V | 0~1200V |
| Resolution | 0.1mV | 1mV | 10mV |
| Precision | 0.02%+0.02%F.S. | ||
| Current Readback | |||
|---|---|---|---|
| Setting Range | Below 100A | Below 1000A | Above 1000V |
| Resolution | 0.1mA | 1mA | 10mA |
| Precision | 0.05%+0.05%F.S. | ||
| Power Readback | |||
|---|---|---|---|
| Setting Range | 0~100%F.S. | ||
| Resolution | 0.01W | ||
| Precision | 0.2%+0.2%F.S. | ||
DYNAMIC MODE
| T1 & T2 | 0.020-100S | ||
|---|---|---|---|
| Resolution | 1μs | ||
| Precision | 1μs+100ppm | ||
| Rise/Fall Slope | 1mA-0.5%F.S./uS | 1mA-2.5%F.S./μS | 10mA-5%F.S./μs |
| Slope Resolution | 0.1mA/μs(below 100A) | 1mA/us(above 100A) | 10mA/μs(above 1000A) |
| Minimum Rise Time | 20μs | ||
| Current Accuracy | 0.2%F.S. | ||
Access our Download Center and Find Out Related Data Sheets
From detailed integration manuals to the latest firmware, our Download Center provides the technical depth required for high-precision power electronics development. Enhance your ActionPower systems today.
INQUIRE FOR YOUR DC ELECTRONIC LOAD

Sales Network & Locations
If you are looking for an automated test system to validate your products during development and research stages to make sure of their successful commercial launch, ACTIONPOWER will be at your disposal to study your specifications and requirements to provided either standard or customized testing solutions.
Join Our Network as a Distributor?
Interested in ACTIONPOWER's testing solutions and equipment and want to promote them in your market? Contact us to joint our global sales network to grow together as partners.