Series
Battery Pack Cycler ATE
Automated Testing Equipment for EV Battery Validation and R&D
The ActionPower BTS Battery Test System is a scalable, high-precision platform for EV and ESS battery testing, specifically for battery pack level with smart software-controlled and emulated charging and discharging dynamics. It features a bidirectional power supply, automated charge/discharge cycles, and 24/7 unattended operation, with integration for thermal chambers and BMS units.
Built on Power HIL architecture, it simulates driving profiles, regenerative braking, and fault conditions in real time—without physical vehicle hardware. With modular design, BMS communication (CAN, RS485), and energy feedback to the grid, it streamlines EV battery R&D, verification, and production testing.
- Multi-channel implementation and scalable design
- Integrated control through a single interface to monitor and manage various systems in parallel or series
- Automated report generation in accordance to applicable battery charge & discharge standards and regulations.
- Dynamic simulation of EV driving status with transient condition setting to verify battery capability
- Improved data security and responsiveness with minimum logging interval of
- Flexible communication protocol to connect inline with water cooler, temperature chamber and BMS to form power-HIL
- Regenerative load technology with an energy recovery rate of 93% feeding back to grid

Model Options
Find the right specification for your requirements
| Model | Channel | Power (W) | Voltage (V) | Current (A) | Dimension (L×H×W mm) | Weight (kg) |
|---|---|---|---|---|---|---|
| BTS-30-1206 | 1 | ±300 | 20~1200 | ±600 | 1210×1955×1000 | 880 |
| BTS-40-1208 | 1 | ±400 | 20~1200 | ±800 | 1210×1955×1000 | 940 |
| BTS-50-1210 | 1 | ±500 | 20~1200 | ±1000 | 1210×1955×1000 | 1000 |
| BTS-60-1212 | 1 | ±600 | 20~1200 | ±1200 | 1210×1955×1000 | 1080 |
| BTS-30-1206-2 | 2 | ±300 | 20~1200 | ±600 | 1810×1955×1000 | 1380 |
| BTS-40-1208-2 | 2 | ±400 | 20~1200 | ±800 | 1810×1955×1000 | 1440 |
| BTS-50-1210-2 | 2 | ±500 | 20~1200 | ±1000 | 1810×1955×1000 | 1580 |
| BTS-60-1212-2 | 2 | ±600 | 20~1200 | ±1200 | 1810×1955×1000 | 1660 |
Highlighted Features
Upscale Your Power Level by Combining New to Existing
The scalability of ACTIONPOWER’s BTS Battery Test System empowers customers with unmatched flexibility in EV battery validation. Whether testing single cells, modules, or full packs, the modular architecture allows users to scale channels and power levels as their testing needs evolve.
This means lower initial investment, seamless future expansion, and faster adaptation to new battery technologies—significantly reducing total cost of ownership and improving long-term ROI.

System Architecture & Scalability
- Multi-device coordination: Control up to 128 channels across multiple systems with one client.
- Modular and scalable design: Cabinet-level or multi-unit parallel connection for current/power expansion.
- Flexible hardware integration: Compatible with thermal chambers, chillers, BMS, and third-party devices.
Versatile Testing Capabilities for International Standards
AND MORE OF YOUR PERSONALIZED SPECIFICATIONS








The ACTIONPOWER BTS Battery Test System is a highly adaptable platform designed to support comprehensive EV battery testing in accordance with international and Chinese standards such as:
- GB/T 31467.1-2015 – High Power Application Test Procedures for Lithium-ion Battery Packs and Systems for EVs
- GB/T 31467.2-2015 – High Energy Application Test Procedures
- GB/T 31467.3-2015 – Safety Requirements and Test Methods
- GB/T 31484-2015 – Cycle Life Requirements and Test Methods
- GB/T 31485-2015 – Safety Requirements and Test Methods
- GB/T 31486-2015 – Electrical Performance Requirements and Test Methods
The system supports a wide range of test items to meet diverse testing requirements across R&D, validation, and compliance workflows:
With its modular structure, programmable control, and real-time data monitoring, the BTS system ensures reliable and efficient execution of complex battery validation protocols under standardized or customized conditions.

Regenerative Discharge for Sustainable Testing Processes
ACTIONPOWER’s BTS Battery Test System features advanced regenerative discharge that recycles over 93% of the energy during battery discharging, as an advantage of which the users are able to maintain sustainable their electricity consumption for testing and reduce carbon footprint by returning energy efficiently to the charging channel or the utility grid.
A more environmentally friendly testing process is achieved by our excellent regenerative power flow and operating processes.
Intelligent HMI and Powerful Software

With intelligent coordination, a single client can control multiple test systems simultaneously, supporting up to 128 channels in parallel. This significantly improves testing efficiency, enhances flexibility, streamlines operations, and reduces both hardware cost and maintenance workload—all while ensuring high-precision data processing.
- Automatic acquisition of battery temperature, voltage, and other key parameters
- Rapid fault detection and localization
- Efficient issue diagnosis and resolution
- Centralized equipment management with real-time status monitoring
- Built-in report templates with one-click test report generation
- Unlimited step programming for complex working condition simulation
- Supports filtering and triggering functions for automatic data analysis and fault tracing
Millisecond-Level Signal Capture
The system enables high-speed signal capture to accurately replicate rapid current and power waveform changes during extreme start-stop conditions in electric vehicles. This capability allows comprehensive validation of battery performance under transient loads, providing reliable data support for both battery R&D and production quality assurance.
±0.02% F.S.
Current/Voltage Accuracy±0.05% F.S.
Power Accuracy200 V/ms
Voltage Slew Rate4 ms
Current Rise Time8 ms
Current Transition TimeBattery Cycling ATE
Integrated testing platform for EV battery pack and energy storage systems
Applications of Battery Pack Testing Systems in ESS (Energy Storage Systems)
In large-scale energy storage systems, battery pack testing systems are primarily used to verify safety, reliability, and consistency during long-term operation.
- Simulate different charge–discharge cycles to evaluate lifetime and capacity degradation.
- Perform Battery Management System (BMS) validation to ensure voltage, current, and temperature stay within safe limits.
- Enable fault simulations (overcharge, over-discharge, short circuit) to test protection mechanisms under extreme conditions.
- Support grid-connected performance tests (e.g., frequency regulation, peak shaving) to confirm ESS responsiveness.

Applications of Battery Pack Testing Systems in Automotive Batteries
For electric vehicle batteries, testing focuses more on dynamic performance and safety.
- Conduct charge–discharge cycling under varying C-rates to assess acceleration, hill-climb, and regenerative braking performance.
- Validate SOC/SOH estimation accuracy to support range prediction and life-cycle management.
- Verify fast charging and high-power discharging stability along with thermal management efficiency.
- Simulate harsh environments—crash, extreme cold, overheating—to meet standards such as UNECE R100 and ISO 6469.

Specifications
The following specifications are subject to modifications and changes without notification in advance. All specifications measured are at product's maximum ratings, if not otherwise noted.
AC SPECIFICATIONS
| Input Voltage | Three-phase + PE, voltage range: 342–456 VAC at full load |
|---|---|
| Grid Frequency | 50 Hz ± 5 Hz |
| Power Factor | 0.99 @ 400 VAC, full load |
| Grid-Side THDi | < 5% @ 400 VAC, full load, with grid THDu < 2% |
FUNCTIONS
| Operating Mode | Constant Voltage (CV), Constant Current (CC), Constant Power (CP), Constant Resistance (CR), Constant Current to Constant Voltage (CC–CV), Constant Voltage with Current Limit, Pulse Mode, Ramp Mode, Rest Mode, Curve Mode, Working Condition Simulation |
|---|---|
| Test Functions | Working Condition Simulation Test, Capacity Test, Cycle Life Test, Battery Pack Consistency Test, DC Internal Resistance Test, Endurance/Range Test, Voltage/Capacity/Power Test, Charge–Discharge Characteristics Test, Reliability Test, Overcharge & Over-discharge Tolerance Test, Temperature Test, C-Rate Test, BMS Following Test, Current–SOC Matrix Test |
| Cut-off Conditions | Customizable limits for current, voltage, time, capacity, energy, temperature, pressure, and BMS parameters |
| Linked Test / Interlock Test | Support for interlocked testing across channels, BMS, EOL, MTV/MTS, and external systems |
| Expression | Custom variables support mathematical operations; expressions can be used as main parameters, outputs, or protection conditions (functions: sin, cos, tan, cot; operators: +, -, *, /) |
| Working Condition Simulation / Scenario Simulation | Support importing working conditions from Excel or TXT files; support current matrix conditions and peak shaving of working-condition voltage and current |
| Current Matrix Test | Matrix software reads real-time SOC and temperature; queries lookup table for corresponding current; sends current to charge–discharge equipment, which executes charging or discharging at that current |
| Current Tracking | Normal constant-current charging or discharging process directly follows BMS signals such as “Maximum Allowable Charge Current” or “Maximum Allowable Discharge Current” |
| Voltage Following / Voltage Tracking | BMS sends voltage limit to charge–discharge equipment, which outputs constant voltage to control charge–discharge test |
| Parallel Function | Supports dual-channel parallel connection, current-type expansion, and power-type expansion |
| Voltage Drop Compensation | Compensates voltage drops across connections to ensure accuracy during testing |
| Offline Operation | Supports continuous operation for 24 hours after upper-computer failure; middle controller stores data locally; data is automatically uploaded once system recovers |
CONTROL INTERFACE
| Communication Interface | Ethernet, CAN, CAN FD, RS485 |
|---|
OPERATING CONDITIONS
| Operating Temperature | 0 °C ~ 45 °C |
|---|---|
| Storage Temperature | -40 °C ~ 70 °C |
| Altitude | < 2000 m |
| Operating Humidity | 0 ~ 95% RH, non-condensing |
FUNCTIONAL PARAMETERS
| Voltage Output Accuracy | ±0.05% F.S. @ 25 °C (optional ±0.02% F.S.) |
|---|---|
| Voltage Resolution | 1 mV |
| Voltage Ripple (RMS) | 0.2% F.S. |
| Current Output Accuracy | ±0.05% F.S. @ 25 °C (optional ±0.02% F.S.) |
| Current Resolution | 1 mA |
| Current Ranges | Optional (configurable) |
| Minimum Output Current | 0.5 A |
| Current Ripple (RMS) | 0.2% F.S. |
| Current Overshoot | None |
| Power Accuracy | ±0.1% F.S. @ 25 °C (optional ±0.05% F.S.) |
| Power Resolution | 1 W |
| Current Response Time | < 4 ms |
| Current Switching Time | < 8 ms |
| Charging Efficiency | 94% |
| Discharging Efficiency | 93% |
DATA LOGGING
| Data Format | CSV format supported for export |
|---|---|
| Recording Method | Supports logging of time difference, current difference, capacity difference, and energy difference |
| Minimum Recording Interval | 10 ms |
PROGRAMMING CONTROL
| Number of Cycles | 100,000 times |
|---|---|
| Programmable Steps | 65,535 steps |
| Loop Nesting | Supports nested loops with a maximum depth of 30 layers |
| Programming Features | Each step can have one or multiple exit conditions |
PROTECTION
| Input-Side Protection | Grid under-voltage/over-voltage protection, frequency protection, phase loss protection, anti-islanding protection, AC short-circuit protection, surge protection, lightning protection, leakage current protection |
|---|---|
| Battery-Side Protection | Under-voltage protection, over-voltage protection, total voltage upper/lower limit protection, cell voltage upper/lower limit protection, abnormal voltage fluctuation protection, over-current protection, current upper limit protection, abnormal current fluctuation protection, short-circuit protection, overpower protection, over-temperature protection, abnormal temperature fluctuation protection, overcharge & over-discharge protection, capacity upper/lower limit protection, battery BMS crash/disconnection protection, reverse polarity protection, loose connection protection, inter-channel wiring error protection, trend protection |
| Other Protection | Self-check protection, power-off data resume, communication disconnection protection, thermal chamber fault linkage protection, water chiller fault linkage protection, external I/O (10 signals) linkage protection, fan fault protection |
MECHANICAL PARAMETER
| Protection Grade | IP32 |
|---|---|
| Cooling Method | Intelligent forced air cooling |
Access our Download Center and Find Out Related Data Sheets
From detailed integration manuals to the latest firmware, our Download Center provides the technical depth required for high-precision power electronics development. Enhance your ActionPower systems today.
Get in Contact

Sales Network & Locations
If you are looking for an automated test system to validate your products during development and research stages to make sure of their successful commercial launch, ACTIONPOWER will be at your disposal to study your specifications and requirements to provided either standard or customized testing solutions.
Join Our Network as a Distributor?