TITAN Series
Source-Load Integrated AC Load Simulator

Four Quadrant Utility-Scale Load Emulation Platform for Source-Side Performance Validation



TITAN AC Load Simulator is a structurally enhanced source-load integrated AC simulator built on the foundation of TITAN Grid Simulator with an additional load cabinet functionally incorporated for four-quadrant, bidirectional and regenerative testing application with controllable regulation on active and reactive power, X/R and SCR, RLC network modelling and non-linear load emulation.

Functioning together with MW-scale battery simulator and PV simulator like TITAN DC, TITAN AC Load Simulator operates at the AC side for validating dynamically and realistically high-power sources including grid-tied inverters, ESS PCS, UPS systems, fuel cells and EV charging equipment (V2G testing), meanwhile returning the absorbed energy back to the utility grid for efficient and low-loss long-duration operation with a 94% efficiency.

TITAN AC Load Simulator is further with DMPS (Digital Matrix Parallel System) feature for flexible deployment and platform re-composition so that the MW & MVA testing system can match evolving power rating, variant prototypes, and their pre-compliance testing applications, without compromising your CAPEX & OPEX by ruling out the essentialness of platform replacement.


Highlighted Advantages
  • 860 VAC high-voltage L-N capability for matching modern 1,500V-class DER converter ratings
  • High-power density of 115.99 kVA/m2 and 82.85 kVA/m3 for MVA testing platform setup
  • DMPS (Digital Matrix Parallel System) capability for flexible platform re-combination and setup
  • Maximum power rating of up to 10MVA for utility-scale AC-side validation
  • Integrated RLC networking circuits, linear and non-linear models with fast dynamic response
  • Independent phase control for single-phase, split-phase, and three-phase configurations
  • Built-in SCR and X/R modes for replicating complex PCC conditions
  • Pre-compliance ready software for fast testing environment setup without tedious programming and engineering
Model Options
Features
Applications
Specifications

Model Options

Find the right specification for your requirements

ModelPower(kVA)Voltage Range@L-NFrequency Range(Hz)Max. Current(A)@3-PhaseWeight(kg)Size(mm)
TA300-450-05L3000-45040-7050029302910x1955x1200
TA400-450-06L4000-45040-7060032202910x1955x1200
TA500-450-08L5000-45040-7080043604210x1955x1400
TA600-450-09L6000-45040-7090049104410x1955x1400
TA750-450-12L7500-45040-70120061604410x1955x1400
TA1K0-450-16L10000-45040-70160087208410x1955x1400
TA300-700-03L3000-70040-7030028602910x1955x1200
TA400-700-04L4000-70040-7040030402910x1955x1200
TA500-700-05L5000-70040-7050032602910x1955x1200
TA600-700-06L6000-70040-7060041704210x1955x1200
TA750-700-07L7500-70040-7070058804210x1955x1400
TA1K0-700-10L10000-70040-70100066104410x1955x1400
TA300-860-03L3000-86040-7030028602910x1955x1200
TA400-860-04L4000-86040-7040030402910x1955x1200
TA500-860-05L5000-86040-7050032602910x1955x1200
TA600-860-06L6000-86040-7060041704210x1955x1200
TA750-860-07L7500-86040-7070058804210x1955x1400
TA1K0-860-10L10000-86040-70100066104410x1955x1400

Highlighted Features

TITAN AC Load Simulator responds to externally supplied voltage and frequency, providing controlled power absorption and programmable load behavior for AC-side validation of PCS, PV inverters, and BESS converters.


Four Quadrant, Source-Load Integrated Regenerative Architecture

TITAN AC Load Simulator is a four-quadrant system with complex load emulation capability built on the TITAN Grid Simulator platform with additional load cabinets that combines advanced programmable load capability, dedicated emulation hardware and network. While TITAN Grid Simulator is simply a regenerative load when operating with a source, TITAN AC Load Simulator responds to externally supplied voltage and frequency while absorbing active power and controlling reactive power across inductive and capacitive operating regions.

TITAN AC Load Simulator reduces thermal stress, cooling demand, and operating cost during long-duration, high-power testing for DER converters, PCS, PV inverters, UPS systems, and other AC sources by regenerating the absorbed energy back to the facility grid instead of dissipating as heat.

4 quadrant operation grid simulator

Screenshot of the Action Power software interface for Anti-islanding testing. The upper 'Measure' section displays a test topology diagram featuring an AC power source on the left, switches S1 and S2, a parallel RLC load in the middle, and the Equipment Under Test (EUT) on the right, along with real-time measurements for voltage, current, and power. The lower 'Settings' section contains two panels: 'Power Grid' on the left for setting grid parameters like 220V and 50Hz, and 'RLC Load' on the right for configuring the specific power parameters of the three-phase RLC load

Programmable RLC, Nonlinear, and Rectified Load Emulation

TITAN AC Load Simulator integrates configurable RLC load network topologies, including series, parallel, and hybrid combinations. Resistance, inductance, and capacitance values can be adjusted independently to create different equivalent load impedance characteristics for flexible source evaluation.

In addition to linear RLC loads, TITAN AC Load Simulator supports nonlinear and rectified load behaviours commonly found in real-world applications, including diode-rectifier type loads and programmable crest factor conditions. The profiles simulated by TITAN introduce current distortion, phase shift, power factor variation, and dynamic stress to the source under test.


AC load simulator - interruption ride through is faster than 1ms

Transient Control-Loop Performance with Sub-Millisecond Dynamic Load Response

Operating in current-controlled load mode, TITAN achieves a dynamic response time below 1 ms (10–90%), allowing fast transitions between load levels, impedance states, or power factor settings. The high-speed response enables accurate evaluation of transient behavior, protection response, and control-loop stability—performance aspects that are often hidden when using slow or static load banks.


Controlled Power Factor and Reactive Power with On-Demand Inductive and Capacitive Loading

TITAN supports programmable power factor control across both inductive and capacitive regions, enabling independent adjustment of active and reactive power absorption. Engineers can stress the DUT across its full operating envelope while voltage and frequency remain externally imposed by the source under test.

This capability is essential for validating power factor correction strategies, reactive power control algorithms, and system stability under complex loading conditions.

In CC mode rectifier-type load with CF = 2.5 voltage amplitude steps to 120 V at 90 phase angle

Testing Automation with Programmable Load Profiles and Sequencing

Testing Automation with Programmable Load Profiles and Sequencing

The system supports STEP, LIST, and PULSE operating modes, allowing users to define complex load profiles with precise control over current, power, impedance, ramp rate, dwell time, and sequence order. External triggering and looping functions support automated test execution in both R&D and production environments.

This programmability ensures repeatable test conditions and consistent results across multiple test cycles and test stations.


Modular Cabinet Architecture with DMPS Matrix Parallel Operation

Each TITAN AC Load Simulator cabinet functions as a modular power unit that can be combined into scalable MVA-level test platforms through DMPS-supported matrix parallel operation. Multiple power units can be flexibly assigned, parallelled, or reconfigured across single-phase, split-phase, three-phase, and multi-channel test setups, allowing users to adapt the same platform to different DUT ratings, phase configurations, and power levels without replacing the entire test system.

The DMPS Digital Matrix Parallel System uses high-speed SFP fiber communication to coordinate multi-module operation with communication speed up to 800 Mbps and loop latency around 1.2 μs. The fiber-based architecture provides inherent electrical isolation, avoids ground-loop issues, and improves immunity to common-mode interference and IGBT switching noise, helping maintain stable control quality as the system scales.

By reusing and recombining the same modular cabinets across multiple applications, laboratories can avoid purchasing separate dedicated platforms for each test scenario, improve equipment utilization, and reduce CAPEX, OPEX, lab footprint, cooling demand, and maintenance effort.

Composite image showcasing a 6MW Grid-Forming Test Platform. The top half is a photograph of large white industrial testing cabinets installed side-by-side with large metal ventilation ducts overhead; a sign in the background reads '6MW GFM Test Platform'. The bottom half is the corresponding CAD layout diagram, showing six equipment units arranged in two rows, with detailed annotations for DC and AC busbar routing, labeled DC1 to DC6 and AC1 to AC6.

Integrated Measurement, Protection, and Control Interface

Optional Modules for Impedance Scanning, SCR Emulation, and External Sampling

TITAN AC Load Simulator supports optional accessory modules for advanced source-load and grid-interaction testing. With impedance scanning, SCR adaptation inductors, and external sampling terminals, the platform can be configured for deeper analysis of converter stability, weak-grid behavior, islanding test circuits, and high-voltage measurement points.

  • Impedance Scanning Terminal (AGS-A2401): supports impedance sweep testing to evaluate equivalent impedance, phase response, resonance behavior, and stability margin of the DUT and connected AC test system.
  • SCR Adaptation Inductor Cabinet (AGS-A2403): adds configurable inductive impedance for SCR weak-grid emulation, helping reproduce challenging PCC conditions for PCS, PV inverter, and BESS converter stability validation.
  • External Sampling Terminal (AGS-A2402): expands sampling to external points such as PCC terminals, islanding circuits, high-voltage nodes, and remote DUT connections for improved measurement correlation in complex test setups.

Integrated Measurement, Protection, and Remote Interfaces

High-accuracy measurement of voltage, current, power, energy, and power factor is built into the TITAN platform. Protection functions including over-voltage, over-current, over-temperature, and abnormal waveform detection help ensure safe operation under demanding AC load test conditions.

Local touchscreen control and remote interfaces such as LAN and RS-485 enable integration into automated test systems and centralized laboratory control environments.

Integrated Measurement, Protection, and Control Interface

Fields of Application

Flexible AC Load Simulator for Source Power Evaluation at Utility-Scale


Utility-Scale PV Inverter AC-Side Output Testing

TITAN AC Load Simulator supports AC-side validation of utility-scale PV inverters by reproducing programmable load and grid-side operating conditions at the inverter output. When combined with a solar array simulator, engineers can evaluate the complete DC-to-AC conversion chain, including MPPT response, AC output regulation, power quality, and grid-connected operating behavior.

Typical test items include RLC load simulation, active and reactive power absorption, power factor control, nonlinear and rectifier-type load profiles, dynamic load steps, harmonic and interharmonic disturbance, voltage sag/swell, frequency variation, and three-phase unbalance. Reference standards may include IEEE 1547 / IEEE 1547.1, UL 1741 SB, IEC 62116, IEC 61727, EN 50549, VDE-AR-N 4105, GB/T 14549, GB/T 24337, and IEC 61000-4-13, depending on the target market and certification scope.

Test system topology diagram for a PV Inverter or PCS. On the left, a TITAN Series Solar Array Simulator (SAS) provides DC input, with an orange box highlighting '2000 VDC Solar Array Simulation' and '10 MW High Power Capability'. The center shows the Device Under Test (comprising DC-DC Inverters, a DC Link, and a DC-AC Inverter). The AC output connects to a TITAN Series Regenerative Grid Simulator on the right, with a blue box highlighting '10 MVA Grid Emulation' and 'Integrated RLC Load Circuit'. At the top, Measuring Instruments monitor data across the system. The bottom displays four SAS software modes: SAS Mode, Table Mode, Shadow Mode, and List Mode.

PCS and BESS Converter Grid-Interaction Validation

For PCS and BESS converter validation, TITAN AC Load Simulator can be used as part of a source-load integrated test platform together with a battery simulator or DC power supply. The setup allows engineers to reproduce battery-side charge and discharge behavior while validating AC-side converter response under programmable load, PCC, and weak-grid conditions.

Typical test items include PCS charge/discharge operation, active/reactive power control, RLC load modeling, SCR and X/R weak-grid emulation, PLL stability, LVRT/HVRT, phase jump, three-phase voltage unbalance, frequency ride-through, harmonic immunity, and anti-islanding related test setups. Reference standards may include IEEE 1547 / IEEE 1547.1, UL 1741 SB, IEC 62116, EN 50549, VDE-AR-N 4105 / 4110, NRS 097-2-1, G99/G83, EN50438, IEC 61000-4-13, and GB/T 15543.

Test system topology diagram for a Power Conversion System (PCS). On the left, a TITAN Series Battery Simulator Power Supply provides DC input, with an orange box highlighting 'Megawatt Battery Simulation Software, Regenerative Load Function'. The center shows the PCS under test, comprising DC-DC inverters, a DC Link, and a DC-AC inverter. On the right, a TITAN Series Regenerative Grid Simulator receives the AC output, with a blue box highlighting '10 MVA Grid Emulation, Integrated RLC Modelling Circuit'. At the top, measuring instruments monitor data across all key nodes via dashed lines.

UPS and Critical Power Source Load Validation

TITAN AC Load Simulator provides programmable AC loading for UPS systems and critical power sources, allowing engineers to verify output performance under realistic linear, nonlinear, and rectifier-type load conditions. Combined with a grid simulator on the input side and a battery simulator on the DC side, the platform can reproduce normal grid operation, grid outage, transfer, backup, and recovery scenarios.

Typical test items include grid outage injection, interruption ride-through, transfer response, crest factor loading, low power factor loading, dynamic load steps, overload response, thermal endurance, voltage regulation, output frequency stability, and current distortion under nonlinear loads. Reference standards may include IEC 62040-3 for UPS performance testing, IEC 61000-4-11 / IEC 61000-4-34 for voltage dips and interruptions, IEC 61000-4-13 for harmonics and interharmonics, and IEC 61000-4-15 / IEC 61000-3-3 where flicker-related evaluation is required.

Topology diagram of a power testing system. The central device is connected to a Battery Backup Unit on top. On the left, a TITAN Series MVA Grid Simulator provides 3-Phase AC input, controlled by a Test Control PC with waveform screenshots illustrating 'Grid Disturbance and Fault Injections' below it. On the right, a Regenerative AC Load Simulator receives the AC Output, with a dashed line indicating its capability to regenerate energy back to the Utility Grid.

EV Charging and Power Electronics Source Validation

TITAN AC Load Simulator supports AC-side validation of EV charging equipment and high-power electronic converters by reproducing programmable source or load conditions around the charger, power module, or converter under test. In EV charger setups, the platform can be combined with an EV battery simulator and regenerative grid simulator to evaluate both grid input behaviour and charging-side power conversion performance.

Typical test items include charger input disturbance testing, voltage sag and swell response, frequency variation, harmonic and interharmonic immunity, PFC behavior, dynamic power transition, regenerative loading, automated charge profiles, and abnormal grid condition response. Reference standards may include IEC 61851, ISO 15118, IEC 61000-4-11, IEC 61000-4-13, IEC 61000-4-34, EN 50549, IEEE 1547, and regional grid-code requirements for EVSE and distributed power conversion equipment.

Topology diagram for an EV charger testing system. On the right, a TITAN Series High-Power Regenerative Grid Simulator provides an INPUT current, with a blue box highlighting 'Software and Testing Automation, Grid Anomaly and Disturbances'. In the center are the EV Chargers under test. On the left, a TITAN Series EV Battery Simulator receives the 'Charge' current, with an orange box highlighting 'Battery Simulation Software, Regenerative Load Function'.

Specifications

The following specifications are subject to modifications and changes without notification in advance. All specifications measured are at product's maximum ratings, if not otherwise noted.

Source Mode

AC Output

BASIC PARAMETERS
Output PhaseThree-phase three-wire ABC or three-phase four-wire ABCN
Load Power Factor-1 ~ +1
VOLTAGE
Setting Resolution (V)0.01
Accuracy±0.1% F.S.
Waveform TypeSine
DC Component (mV)<50
Voltage Distortion <0.5% @ 50Hz / 60Hz, ≥220V, no load
<1.0% @ 50Hz / 60Hz, ≥220V, linear load
<1.0% @ other frequency points, ≥220V, no load
<1.5% @ other frequency points, ≥220V, linear load
Load Regulation±0.1% F.S.
Line Regulation±0.1% F.S. @ 10% variation
Voltage Slew RateAC >1.0 V/µs
Dynamic Response<1 ms (10% ~ 90% Umax)
Three-Phase UnbalanceDoes not exceed half of GB/T 15543-2008 limits: negative-sequence voltage ≤1%, short-term ≤2%
FREQUENCY
Setting Resolution (Hz)0.001
Accuracy±0.005Hz
PHASE SETTING
Setting RangeA = 0°, B = 240°, C = 120° by default; each phase independently adjustable from 0° ~ 359.9°
Accuracy±0.3°
Setting Resolution0.1°
HARMONICS
Harmonic OrdersUp to 50th order @ 50Hz / 60Hz, below rated voltage
Harmonic Content 2nd ~ 10th: max 40% per order, total harmonic content ≤50%
11th ~ 20th: max 20% per order, total harmonic content ≤20%
21st ~ 30th: max 10% per order, total harmonic content ≤10%
31st ~ 50th: max 5% per order, total harmonic content ≤10%
Amplitude Error±1% no load; ±3% with load
Phase Angle Range0° ~ 359.9°
Preview FunctionPreview of harmonic superimposed waveform available
Edit ModeImport, export, read, and store supported

Measurement Parameters

OUTPUT VOLTAGE
Resolution (Vrms)0.01
Accuracy±0.1% F.S.
OUTPUT FREQUENCY
Resolution (Hz)0.001
Accuracy±0.005Hz
OUTPUT CURRENT
Resolution (A)0.1
Accuracy±0.2% F.S.
ACTIVE POWER
Resolution (kW)0.001
Accuracy±0.3% F.S.
APPARENT POWER
Resolution (kVA)0.001
Accuracy±0.3% F.S.
POWER FACTOR
Range-1.00 ~ +1.00
Resolution0.001

AC Output

INTER-HARMONICS
Frequency Range1Hz ~ 3000Hz, content <10%
Programming Steps100 steps
Programmable ParametersContent, start frequency, end frequency, frequency increment, execution time, interval time, number of cycles
Edit ModeAdd, delete, import, export, store, and read
FLICKER
Flicker Levels1 ~ 10, 10 levels in total, one-click selection
Adjustment Step Size1
Accuracy±0.2
Preview FunctionFlicker trend chart preview available
THREE-PHASE VOLTAGE UNBALANCE SIMULATION
Adjustment MethodThree-phase voltage, phase angle, unbalance factor, and duration
Unbalance Factor Range (%)1 ~ 100, one-click Class 123x selection
Unbalance Factor Step Size (%)0.01
Accuracy (%)±0.2
LVRT / HVRT
ModesLow-voltage ride-through, high-voltage ride-through, and combined LVRT / HVRT
Configuration ParametersVoltage, frequency, phase, rise time, hold time, trigger phase angle, trigger pulse output
Related StandardsGB standards, VDE-AR-N 4105, NRS 097-2-1, G83, EN50438, and others
SCR SIMULATION
SCR Range1 ~ 10; setting shall not exceed source output capability
AMPLITUDE MODULATION
Programming Steps100 steps
Programmable ParametersModulation amplitude, modulation frequency, hold time, trigger phase angle
Amplitude Range0 ~ 30%
Amplitude Resolution0.01
Frequency Range0 ~ 100Hz
Frequency Resolution0.001
Edit ModeImport, export, store, and read
FREQUENCY MODULATION
Programming Steps100 steps
Programmable ParametersModulation amplitude, modulation frequency, hold time, trigger phase angle
Amplitude Range0 ~ 0.5Hz
Amplitude Resolution0.001
Frequency Range0 ~ 100Hz
Frequency Resolution0.001
Edit ModeImport, export, store, and read
IMPEDANCE SWEEP
Frequency Range1Hz ~ 1000Hz
Frequency Interval1Hz ~ 10Hz: 0.1Hz step; 10Hz ~ 100Hz: 1Hz step; 100Hz ~ 1000Hz: 10Hz step
Amplitude1% ~ 5%
Step Size≥0.1Hz
PROGRAMMING
Programming Steps100 steps
Parameters per StepVoltage, frequency, phase, transition time, hold time, trigger phase angle, trigger pulse output
Rise Time Range100µs ~ 999s
Hold Time Range100µs ~ 999s
Minimum Time Step100µs
Sync Signal OutputOne electrically isolated low-voltage trigger signal synchronized with output parameter changes; supports single-step, single-loop, and single-trigger modes with pulse or level selectable
Edit ModeImport, export, store, and read
Related FunctionsThree-phase unbalance, voltage sag, interruption, LVRT / HVRT, and automation integration interface
Operating ModesRun, stop, nested programming with main and sub loops
Trigger MethodsAutomatic, manual, or external

Supply Mode

Wiring MethodThree-phase three-wire ABC + PE
Frequency (Hz)47 ~ 63
Voltage Range (V)380V ±15% / 690V ±5% / 960V ±5%
Power Factor0.99 @ full load
Maximum Efficiency>93%
Current Harmonics≤3% @ full load

Miscellaneous

Communication InterfaceLAN, RS485
External InterlockInput: normally open / normally closed; output: normally open / normally closed
Trigger SignalTrigger input / output
Insulation & Withstand Voltage10MΩ / DC 500V; 5000VDC / 1min
Control & DisplayLocal touchscreen control and remote PC control; displays voltage, current, frequency, and power
Cooling MethodForced air cooling
Noise≤70dB

Load Mode

Load Mode

BASIC PARAMETERS
Load PhaseThree-phase three-wire ABC or three-phase four-wire ABCN
LOAD MODES
Constant Current ModeCurrent, power factor, load type, current slope, output waveform
Constant Power ModeApparent power, power factor, load type, power slope, output waveform
Constant Resistance ModeResistance value
RLC ModeRLC connection types: R+L+C, R//L//C, (R//C)+L, (R+L)//C, (R+C)//L; resistance, inductance, and capacitance values configurable
Nonlinear LoadCurrent, power, crest factor, current slope, power slope
Zero Voltage StartSimulates load startup from zero voltage; after startup, seamless switching to constant current or constant power modes based on user-defined conditions
VOLTAGE
Allowed Voltage Distortion LimitUTHD <10% below the 20th harmonic order
CURRENT
Current Setting Resolution (A)0.01
Accuracy±0.2% F.S. @ constant current mode
WaveformsSine, square, triangle, clipped waveform, custom waveform
Current Distortion<2% @ 50Hz, rated voltage, full load
Current Slew Rate10% ~ 90% of rated current >1 A/µs
Dynamic Response<1 ms @ 10% ~ 90% of rated current
FREQUENCY
Range (Hz)40.00 ~ 70.0
HARMONICS
Harmonic OrdersUp to 50th order
Harmonic Content 2nd ~ 10th: max 40% per order, total harmonic content ≤50%
11th ~ 20th: max 20% per order, total harmonic content ≤20%
21st ~ 30th: max 10% per order, total harmonic content ≤10%
31st ~ 50th: max 5% per order, total harmonic content ≤10%
Phase Angle per Order0° ~ 359.9°
POWER
Power Setting Resolution (kVA)0.01
Accuracy±0.5% F.S. @ constant power mode
POWER FACTOR
Power Factor Range-1 ~ +1; inductive / capacitive settings supported; current direction configurable
Setting Resolution0.01
CREST FACTOR
Range1.414 ~ 4
Resolution0.001

List Programming

Programming Steps100 steps
Supported ModesConstant current, constant power
Programmable ParametersCurrent / power, power factor, load type, transition time, hold time, trigger phase angle, trigger pulse output
Rise Time Range100µs ~ 999s
Hold Time Range100µs ~ 999s
Minimum Time Step100µs
Sync Signal OutputOne electrically isolated low-voltage trigger signal synchronized with output parameter changes; supports single-step, single-loop, and single-trigger modes with pulse or level selectable
Edit ModeImport, export, store, and read
Operating ModesRun, stop, major loop and minor loop nested programming
Trigger MethodsAutomatic, manual, or external

Measurement Parameters

AC VOLTAGE
Resolution (V)0.01
Accuracy±0.1% F.S.
OUTPUT FREQUENCY
Resolution (Hz)0.001
Accuracy±0.015Hz
AC CURRENT
Resolution (A)0.1
Accuracy±0.2% F.S.
ACTIVE POWER
Resolution (kW)0.001
Accuracy±0.3% F.S.
APPARENT POWER
Resolution (kVA)0.001
Accuracy±0.3% F.S.
POWER FACTOR
Range-1.00 ~ +1.00
Resolution0.001
CREST FACTOR
Range1.414 ~ 4
Resolution0.001

Supply Mode

Wiring MethodThree-phase three-wire ABC + PE
Frequency (Hz)47 ~ 63
Voltage Range (V)380V ±15% / 690V ±5% / 960V ±5%
Power Factor0.99 @ full load
Maximum Efficiency>93%
Current Harmonics≤3% @ full load

Miscellaneous

Communication InterfaceLAN, RS485
External InterlockInput: normally open / normally closed; output: normally open / normally closed
Trigger SignalTrigger input / output
Insulation & Withstand Voltage10MΩ / DC 500V; 5000VDC / 1min
Control & DisplayLocal touchscreen control and remote PC control; displays voltage, current, frequency, and power
Cooling MethodForced air cooling
Noise≤70dB

Related Application Notes

ActionPower Uncomplicates Your Testing Setup Beyond Hardware

Software and Modelling for Streamlining Industrial Grid Code Compliance

Diverse Modelling and Programming Capability

Integrated programming capability and modelling allow ActionPower's grid emulation platforms to replicate, through its FPGA circuit, real-world weak grid conditions of RLC impedance thus replacing the essentialness of RLC load banks and subsequently its thermal management and equipment ownership cost. 

Access our Download Center and Find Out Related Data Sheets

From detailed integration manuals to the latest firmware, our Download Center provides the technical depth required for high-precision power electronics development. Enhance your ActionPower systems today.

Access Download Center

CONTACT US FOR AC LAOD SIMULATOR

Global Contact

Sales Network & Locations

If you are looking for an automated test system to validate your products during development and research stages to make sure of their successful commercial launch, ACTIONPOWER will be at your disposal to study your specifications and requirements to provided either standard or customized testing solutions.

Join Our Network as a Distributor?

Interested in ACTIONPOWER's testing solutions and equipment and want to promote them in your market? Contact us to joint our global sales network to grow together as partners.

Quick Model Access

Smart Discovery

Access our Power Supply Wizard to find the right programmable power supply for your use cases and testing scenarios.

discover programmable power supply by filtering with current, voltage and power ranges
CONTACT US

Contact Us

Professionalism is what we care about. Why not email us with your technical requirements fully explained rather than submitting a simple message so that we revert more proactively with detailed solutions?

Subscribe to Newsletter

Thank you for subscribing!