Home Contact EN

TITAN Series
Battery Simulator Power Supply
High-Voltage Bidirectional DC Platform for E-Mobility, ESS, and Converter Testing



Developing component prototypes such as inverters for DERs like windturbine and solar farm or EV charging system, onboard chargers and V2G technology research, usually requires validating its reliability and stability in operation when connected with, as what will eventually happen in real world after their implementation, a high-voltage and high-power battery system. However, it is fundamentally unrealistic for any EV manufacturers and energy system integration companies to have at their disposition a real battery systems to which then can connect their products for validating, either for reasons of lack of controllability and the high cost. A battery simulator power supply is what you should rely on by contrast, to achieve better effectiveness and testing sequence automation.

TITAN Battery Simulator Power Supply, with legacy model name of ABS series, is a bidirectional power testing equipment that offers maximum level of 2000 VDC and offers parallel connection options for building testing platform with 10MW as maximum power rating of the same. The system's bidirectionality emulates a battery's operation pattern of both consuming and producing battery from one unit, further supported by smart built-in interfaces and remote softwares for users to configure at their discretion and emulate the required battery charging and discharging profile against their products, along side with versatile options for simulating batteries of various chemical compositions.

Highlighted Features

  • DC output voltage covers range from 20 to 1500 VDC or 2000 VDC
  • High Precision: Voltage accuracy ±0.1% F.S., Current accuracy ±0.1% F.S.
  • High Dynamics: Titan series products' load rise/fall time (10%–90%) is 2 ms, positive/negative load switching time (-90%–90%) is 4 ms; voltage slew rate of 200 V/ms;
  • Parallel connection for upscaling to 10MW output power
  • Comprehensive battery chemistry profiles and emulation (LiMn204, LiCoO2, LiFePO4, NiMH, LiTiO2, PbO2, Ternary Li...)
  • Open 1st-, 2nd-, and 3rd-order RC battery models; Simulink battery models upload supported
  • Bidirectional power operation capability and regenerative load technology that recovers 94% power recovery
  • Internal resistance setting and programming through smart software
  • CC, CR, CV, CP output modes supported
Model Options
Features
Applications
Specifications
Downloads
FAQs
Version History

FAQs about TITAN Battery Simulator

› What is a battery simulator power supply?
A battery simulator power supply is a programmable, bidirectional DC power system that emulates the electrical behavior of a real battery pack so the device under test (DUT) can be validated under safe and repeatable conditions. Instead of behaving like a fixed-voltage DC source, it can reproduce battery-like behavior in real time, including voltage droop, current limits, and dynamic responses during charge/discharge transitions.
  • Bidirectional power flow: source power to emulate discharge; sink power to emulate charge or regenerative energy.
  • Battery-behavior reproduction: emulate voltage response under load, internal resistance effects, and state-dependent behavior.
  • Test repeatability: run identical profiles repeatedly for debugging, regression testing, and compliance validation.
  • Safety & practicality: avoid hazards and operational constraints of physical battery packs during development.
› Is a battery simulator the same as a DC power supply?
A battery simulator is not the same as a conventional DC power supply. A standard DC source is primarily designed to output a commanded voltage/current within its regulation capability, while a battery simulator is designed to behave like a battery under dynamic conditions, including charge/discharge reversals and fast transients.
  • Bidirectional capability: many battery test workflows require sinking power (charging emulation), not only sourcing.
  • Dynamic response: battery simulators typically prioritize fast transient handling to reproduce step loads and regenerative spikes.
  • Battery-centric controls: SOC-dependent voltage, internal resistance modeling, and profile-driven behavior are central to battery emulation.
  • Stability with power electronics: chargers/inverters can excite control interactions; battery simulators are built to remain stable under these conditions.
› What is the difference between battery simulation and battery emulation?
The terms are sometimes used interchangeably, but the technical emphasis is different: simulation explains, while emulation validates.
  • Battery simulation is a modeling activity—computing or estimating battery behavior (SoC/SoH, OCV curves, impedance, thermal effects) in software to predict outcomes.
  • Battery emulation is a test-in-the-loop activity—generating that behavior electrically (voltage/current/impedance dynamics) in real time so a charger, inverter, BMS, or PCS can be validated under repeatable and safe conditions.
In product testing, the value of a battery simulator power supply is that it delivers real electrical behavior to the DUT, bridging model intent and hardware reality.
› How does a battery simulator emulate real battery behavior?
A battery simulator emulates real battery behavior through closed-loop control of voltage and current and by applying battery-relevant parameters that define how the “battery” should respond to changing load or charging conditions.
  • Open-circuit voltage (OCV): defines the baseline voltage level as a function of state.
  • State-of-charge (SOC) dependent behavior: changes voltage limits and operating points along a programmed SOC trajectory.
  • Internal resistance / impedance: reproduces voltage sag under load and voltage rise during charging.
  • Charge/discharge constraints: applies current limits, power limits, and boundary conditions to mimic a real pack’s safe operating area.
  • Dynamic transient handling: responds to load steps and regenerative events so the DUT experiences realistic electrical dynamics.
In practice, this allows engineers to program standardized profiles (e.g., CC–CV transitions, pulse loads, or fault-like behaviors) and reproduce them consistently for debug and validation.
› Can a battery simulator both charge and discharge power?
In battery-related validation, both directions of power flow matter. A battery simulator power supply supports bidirectional operation, so it can emulate:
  • Battery discharge (source mode): deliver power to the DUT as if the battery is providing energy.
  • Battery charge (sink mode): absorb energy from the DUT as if the battery is being charged.
  • Regenerative events: capture short-duration energy returned from inverters/motor drives during braking or dynamic transitions.
This is a key differentiator for testing OBCs, DC-DC converters, traction inverters, PCS, and bidirectional converters, where power direction may change frequently during operation.
› How fast is the transient response of a battery simulator?
Transient response defines how accurately a battery simulator can reproduce real-world electrical dynamics when the DUT rapidly changes its demand or returns energy. A battery simulator is typically designed with high control bandwidth so it can handle:
  • Load steps: sudden changes in current demand without unstable overshoot/undershoot.
  • Regenerative spikes: fast current reversals and short power bursts returned by the DUT.
  • Dynamic state transitions: rapid shifts between operating modes (e.g., standby → ramp → steady-state).
For engineering validation, faster and cleaner transient performance improves the credibility of results—especially when characterizing control loops, protection thresholds, and edge-case behaviors.
› Why use a battery simulator instead of a real battery?
Real batteries introduce uncertainty, risk, and operational constraints that can slow development. A battery simulator power supply improves test efficiency by providing a controllable and repeatable electrical environment.
  • Safety: avoids hazards such as thermal runaway, short-circuit energy, and uncontrolled fault behavior.
  • Repeatability: eliminates variability caused by cell aging, temperature, SOC drift, and pack inconsistency.
  • Controllability: instantly changes voltage/current limits and profiles to explore edge cases and boundary conditions.
  • Time efficiency: removes long charge/discharge preparation time typical of real packs.
  • Cost & workflow: reduces consumables and enables automated regression tests in lab environments.
The result is a testing workflow where behaviors are programmable, traceable, and reproducible, which is crucial for debugging and compliance validation.
› What applications require a battery simulator power supply?
Battery simulators are used wherever a battery pack would normally sit in the system, especially when tests require repeatability, safety, and bidirectional power handling.
  • EV onboard charger (OBC) testing: validate charging profiles, protection logic, efficiency, and transient behavior.
  • DC-DC converter validation: characterize input/output dynamics and stress behavior under rapid transitions.
  • BMS verification: validate thresholds, limits, and response under controlled SOC/OCV/impedance conditions.
  • ESS / PCS testing: emulate battery-side behavior to validate PCS charge/discharge control and grid interaction.
  • Bidirectional and V2G/V2X development: reproduce direction changes and energy return scenarios in a lab-safe way.
› Can a battery simulator be used for both component-level and system-level testing?
Battery testing spans from power modules to complete systems, and a scalable battery simulator platform can cover both.
  • Component-level testing: tens of kW class validation for converters, subassemblies, and power stages.
  • System-level testing: hundreds of kW class validation for full drivetrains, charging systems, or storage converters.
  • Higher power expansion: parallel and series configurations enable higher power/voltage envelopes when required.
This scalability helps standardize test platforms across R&D, validation labs, and production test environments.
› What voltage and current ranges can a battery simulator support?
Battery simulator voltage and current ranges are designed to match diverse battery platforms and peak power demands. The practical range depends on platform architecture and whether series/parallel expansion is used.
  • Wide voltage coverage: supports different battery platform voltages across development and validation stages.
  • High current capability: enables pulse testing, peak demand characterization, and stress testing.
  • Expandable configurations: series for higher voltage and parallel for higher current/power envelopes.
In selection, the key is aligning the simulator envelope with the DUT’s operating window and worst-case transient conditions.
› Can different battery chemistries be emulated?
Yes. Battery simulators can emulate different chemistries by configuring the parameters that define electrical behavior across operating states.
  • Voltage profile (OCV vs SOC): chemistry-specific baseline behavior.
  • Impedance characteristics: different cells exhibit different resistance/impedance behavior under load and temperature.
  • Limits & constraints: charge acceptance, discharge capability, and protective boundaries differ by chemistry.
  • Custom models: users can implement proprietary profiles to match real pack measurements.
This allows one hardware platform to support multiple product programs and evolving battery technologies.
› Is a battery simulator suitable for long-duration testing?
Long-duration testing requires stable operation, controllable heat dissipation, and manageable energy cost. A battery simulator power supply is commonly used for endurance and cycling tests because it is designed for sustained operation under programmable profiles.
  • Endurance and cycling: run long charge/discharge cycles without battery degradation variables.
  • Consistent performance: maintain repeatable electrical behavior across hours or days of testing.
  • Regenerative operation: reduces testing energy waste by returning energy where supported.
  • Automated test workflows: enable unattended regression and long-run validation with traceable profiles.

Downloads

Technical resources in relation to the listed system and equipment

Version History

Product naming and model update record (for traceability)

  • Previously: ABS Battery Simulator Power Supply
  • Updated: Sept 2025 — TITAN Series Battery Simulator Power Supply (model update and series renaming; same product line evolution)

This update reflects a series naming consolidation and model upgrade. Core battery simulation and emulation capabilities, including programmable voltage and current profiles, dynamic response, and application coverage, remain continuous across the product line. CE-certified versions of the TITAN Battery Simulator are now available for selected configurations, enabling compliant deployment in regulated laboratory and industrial testing environments beyond the scope of the former ABS series.

CE-Certified Model Options

Find the right specification for your requirements

ModelPower (kW)Output Voltage (V)Output Current (A)Dimensions (mm) W × H × D
TD300-1K5-04±30020~1500±4002010×1955×1200
TD400-1K5-06±40020~1500±6002010×1955×1200
TD500-1K5-07±50020~1500±7002010×1955×1200
TD600-1K5-08±60020~1500±8003410×1955×1200
TD750-1K5-10±75020~1500±10003410×1955×1200

Non-CE-Certified Model Options

Find the right specification for your requirements

ModelPower (kW)Max Voltage (V_DC)Output Current (A)Size (mm)Weight(kg)
TD300-1K2-10±30012-1200±10002010x1955x12002,640
TD400-1K2-10±40012-1200±10002010x1955x12002,850
TD500-1K2-12±50012-1200±12502010x1955x12003,020
TD600-1K2-12±60012-1200±12502410x1955x12003,500
TD300-2K0-04±30020-2000±4001610x1955x12001,900
TD400-2K0-06±40020-2000±6001610x1955x12002,430
TD500-2K0-07±50020-2000±7002010x1955x12002,670
TD600-2K0-08±60020-2000±8003410x1955x12003,500
TD750-2K0-10±75020-2000±10003410x1955x12004,390
TD1K0-2K0-14±100020-2000±14003410x1955x12004,940

Highlighted Features

The TITAN Battery Simulator is a programmable and bidirectional DC power supply that accurately replicates battery characteristics for advanced test and validation applications



Bidirectional Regenerative Battery Simulation with Grid-Friendly Performance

Designed for advanced battery-related test scenarios, the TITAN Battery Simulator provides seamless bidirectional operation to emulate real-world battery charge and discharge dynamics. During charging emulation, TITAN functions as a regenerative load, dynamically absorbing energy from chargers, inverters, or DC buses and returning it to the utility grid with an efficiency of up to 94%.

This capability is particularly critical in applications such as BMS algorithm validation, charger compliance testing, ESS cycling tests, and battery aging simulations. With an input power factor ≥ 0.99 and harmonic current below 3% of full scale, TITAN maintains low grid distortion even under continuous regenerative operation, ensuring stable, efficient, and environmentally responsible battery testing.

Explore more the advantages of regenerative load over resistive load

discover advantages of regenerative power supply

comprehensive battery simulation interface

Internal Resistance Emulation for SoC- and SoH-Dependent Battery Modeling

TITAN incorporates programmable internal resistance (Rint) emulation to model the non-linear and state-dependent behavior of real batteries. Engineers can define resistance characteristics as a function of SoC and SoH, allowing the simulator to reproduce dynamic voltage sag, current-dependent losses, and efficiency variations observed in real battery systems.

This functionality is critical for validating BMS control algorithms, charge termination logic, thermal management strategies, and protection thresholds under dynamic load conditions. By exposing chargers and control systems to realistic battery impedance behavior, TITAN enables more accurate, repeatable, and risk-free testing compared to physical batteries.


Configurable Battery Chemistry Modeling with High-Fidelity Dynamics

TITAN integrates software-defined battery chemistry models that reflect the distinct electrical characteristics of various battery types, including LFP, NCM/NCA, LCO, LMO, LTO, NiMH, and Lead-Acid systems. Users can parameterize each model with cell topology, SoC, temperature, and internal resistance to capture chemistry-specific voltage profiles and dynamic responses.

Supporting first-, second-, and third-order RC equivalent circuit models, TITAN enables advanced customization of battery behavior and allows user-defined models to be imported via CSV files. With a command update rate of up to 1 kHz, the simulator delivers fast transient response and closed-loop accuracy, making it ideal for developing and validating BMS algorithms, converters, and energy storage control systems.

built in battery chemistry types option

fast rise time

Fast Transient Performance for Control Loop and Protection Validation

TITAN delivers high dynamic performance to support validation of fast-changing battery operating conditions. Millisecond-level current rise, fall, and switching times allow engineers to test BMS control loops, protection thresholds, and charger response under abrupt load and mode transitions that cannot be reproduced by slow-response DC sources.

A voltage slew rate of up to 200 V/ms enables precise reproduction of rapid voltage transitions while maintaining controlled overshoot and undershoot. This capability is essential for evaluating system stability, transient robustness, and fault response in high-power battery simulation, converter development, and ESS testing environments.

Dynamic Performance ParameterSpecificationBattery Simulation Test ScenarioEngineering Value in Use Cases
Current Rise Time (10% to 90%)2.4 ms Step-load emulation in EV inverters, motor start-up simulation, sudden power demand changes in ESS converters Enables accurate validation of BMS current control loops, overcurrent detection timing, and transient stability
Current Fall Time (90% to 10%)2.4 ms Abrupt load removal, inverter shutdown, regenerative braking power handover Verifies BMS response to rapid current decay, protection release logic, and system damping behavior
Current Switching Time (−90% to +90%)4.8 ms Fast transition between discharge and charge modes, bidirectional DC/DC and inverter source–sink switching Critical for validating bidirectional power flow control, charger handover stability, and DC bus regulation
Current Switching Time (+90% to −90%)4.8 ms Transition from charging to discharging during regenerative braking or load reversal Ensures realistic emulation of energy direction reversal and exposes potential control-loop oscillations
Voltage Overshoot During Sudden Load24 V (500 V applied) Sudden high-current load connection, contactor closing, inverter step-load events Allows precise verification of overvoltage thresholds, transient voltage tolerance, and protection margins
Voltage Undershoot During Sudden Load Removal22 V (500 V removed) Abrupt load disconnection, inverter or converter shutdown Supports validation of undervoltage detection, ride-through capability, and system stability
Voltage Transition Time at 200 V/ms2.04 ms (136 V → 536 V) Rapid DC bus voltage change, multi-voltage platform switching, abnormal condition injection Enables aggressive dynamic testing of power electronics, insulation margins, and fast-reacting control algorithms

MW-Level Battery Simulation with Consistent Dynamics across Paralleled Units

TITAN enables high-power battery simulation through parallel connection of multiple units, scaling system capacity up to 10 MW without compromising communication integrity or dynamic performance. Each unit operates under synchronized control to ensure uniform current sharing and coordinated transient response.

This capability is essential for multi-channel test benches, parallel charger testing, and large-scale ESS simulations, where mismatched dynamics between paralleled sources can lead to unstable behavior or inaccurate test results. TITAN’s parallel architecture preserves fast response and control accuracy at MW power levels.

parallel connection power upgrading of TITAN Battery Simulator Power Supply

Test Applications of TITAN Battery Simulator

Discover use cases, DUTs, applicable standards and regulations


E-Mobility and Onboard Power Electronics Testing  

Electric vehicle powertrains impose highly dynamic and bidirectional electrical stress on the battery interface during acceleration, regenerative braking, and torque transients. Accurate validation of traction inverters, onboard chargers (OBC), and high-voltage DC/DC converters therefore requires a battery emulator capable of fast current reversal, controlled voltage dynamics, and repeatable transient behavior, without becoming the limiting factor in the test loop.

TITAN delivers bidirectional source–sink operation with high dynamic performance, supporting voltage swing rates up to 200 V/ms and current change rates up to 500 A/ms. Typical current rise times of ≤ 2.0 ms (10–90%) and polarity switching within ≤ 4 ms (–90% ↔ +90%) enable realistic reproduction of traction and regenerative events. With CE-certified output ranges covering 20–1500 VDC and single-unit power blocks from 300 kW to 750 kW, expandable through parallel operation, the platform supports both component-level and system-level EV validation, without the safety and repeatability limitations of real battery packs.

 

Typical DUTs

  • Traction inverters and e-axle drive systems
  • Onboard chargers (OBC)
  • High-voltage DC/DC converters
  • Battery-side interfaces of motor drive test benches

Relevant standards and guidelines

  • ISO 21498 (Electrical propulsion components)
  • ISO 6469 (Electric vehicle safety requirements)
  • OEM-specific EV validation procedures
e-mobility testing with battery simulator

EV Charging & V2X Power Interface Validation

EV Charging & V2X Power Interface Validation

EV charging systems and vehicle-to-everything (V2X) power interfaces operate against a battery interface with continuously changing voltage, current, and impedance during charging, discharging, and bidirectional power exchange. When the battery is treated as an ideal load or source, charging instability, current oscillation, and protection miscoordination are often masked in laboratory tests. TITAN provides a realistic and repeatable battery-side electrical environment for EV charging and V2X validation, supporting high-voltage DC output up to 1500 VDC (CE configurations), scalable power blocks from 300 kW to 750 kW, and fast voltage and current dynamics (200 V/ms, 500 A/ms). Configurable battery models and bidirectional source–sink operation enable accurate verification of control stability, power reversal behavior, and protection coordination without external loads.

 
Typical DUTs
  • DC fast chargers and charging stations
  • Bidirectional EVSE and V2X charging systems
  • V2G / V2H / V2B power interface units
  • Charging controllers and protection modules
Applicable standards & references
  • IEC 61851 – Electric vehicle conductive charging systems
  • IEC 62196 – Plugs, socket-outlets, and vehicle connectors
  • ISO 15118 – Vehicle-to-grid communication interface
  • Regional V2X and grid-interconnection requirements

Battery Energy Storage System (BESS) & PCS Validation

BESS and PCS operate across wide voltage ranges and continuously alternate between charging and discharging modes. Validation requires battery emulation that can reproduce steady-state operation, rapid load steps, and abnormal conditions under deterministic and repeatable control, while supporting long-duration cycling at high power.

TITAN platform supports configurable battery models with programmable parallel configuration, initial SOC, temperature, internal resistance, and capacity, including 1st-, 2nd-, and 3rd-order RC equivalent models and CSV-based profile import. Scalable high-power output combined with regenerative power sinking allows efficient execution of charge/discharge cycles while returning absorbed energy to the grid, significantly reducing thermal stress and energy consumption during extended tests. Measurement accuracy of ±0.1% F.S. for voltage and current and ±0.2% F.S. for power, with 0.001 resolution, provides a consistent basis for efficiency and dynamic performance evaluation.

 
Typical DUTs
  • Power Conversion Systems (PCS)
  • Bidirectional DC/AC converters
  • DC bus protection and control units in BESS
Relevant standards and guidelines
  • IEC 62933 (Electrical energy storage systems)
  • IEC 62477-1 (Safety of power electronic converter systems)
  • Utility and project-level grid interconnection requirements
battery energy storage system development

AI DATA CENTER

AI Data Center: UPS, DC Bus, Battery-Backed Architectures

Modern AI data centers increasingly rely on high-power DC architectures, including UPS systems, battery-backed DC buses, and energy buffering subsystems, to support rapidly varying computational loads. Validation focuses on ride-through behavior, recharge sequences, fast load transients, and protection coordination, often under long-duration operating conditions.

The bidirectional source-sink capability of TITAN is suitable for UPS battery interfaces and DC-side energy buffers. Voltage dynamics up to 200 V/ms, current change rates up to 500 A/ms, and scalable high-power output (300–750 kW per unit, expandable via parallel operation) support realistic simulation of load steps and power reversals. Regenerative energy feedback significantly reduces operating cost during endurance and recharge testing in data-center validation environments.

 
Typical DUTs
  • UPS battery interfaces and energy-storage UPS subsystems
  • DC bus and battery-backed power architectures
  • Bidirectional DC/DC converters for energy buffering
Applicable standards & references
  • IEC 62040 – UPS systems
  • UL 1778 – UPS safety
  • OEM and data-center power architecture validation procedures

Specifications

The following specifications are subject to modifications and changes without notification in advance. All specifications measured are at product's maximum ratings, if not otherwise noted.

GENERAL SPECIFICATIONS

Output ModesConstant Voltage (CV), Constant Current (CC), Constant Power (CP), Programmable Output, and PV Standards (EN50530/Sandia) for Static and Dynamic MPPT Tracking and Solar Array Simulation
Energy RegenerationPower sinking and regenerative feedback to grid
Electrical IsolationInput/Output Electrical Isolation
Parallel Operation CapabilityMultiple Units of the Same Model Can Be Parallelled

DC OUTPUT

VOLTAGE
Setting Resolution0.01
Accuracy±0.1 F.S.
RMS Ripple0.1% F.S. (Resistive Load)
Voltage Swing Rate200V/ms
                       
CURRENT
Setting Resolution0.01
Accuracy±0.1% F.S.
RMS Ripple0.1% F.S. (Resistive Load)
Changing Rate500A/ms
Rise Time≤2.0ms (10%-90% @ rated current)
Switching Time≤4ms (between -90% and +90%)
Peak Time60s (1200VDC)
BATTERY SIMULATION
Battery typeSupports simulation of various battery chemistries, including:
  • Lithium-ion: LMO (Lithium Manganese Oxide), LCO (Lithium Cobalt Oxide), LFP (Lithium Iron Phosphate), NMC (Nickel Manganese Cobalt), LTO (Lithium Titanate)
  • Other chemistries: NiMH (Nickel-Metal Hydride), Lead-Acid
  • Custom battery models: Open 1st-order, 2nd-order, and 3rd-order RC equivalent circuit models
  • Configurable ParametersSeries & parallel cell count, Initial SOC (State of Charge), Initial temperature, Internal resistance, Cell capacity
    InterfaceSupports CSV import for custom models
    Real-Time Performance1ms command update rate for high-speed dynamic simulation
    UNIVERSAL PROGRAMMING FUNCTIONS
    Programming Steps200 steps
    Programming ParametersVoltage/Current, Rise Time, Hold Time, Trigger Pulse Output
    Rise Time Range1ms ~ 99999s
    Flat Top Time Range1ms ~ 99999s
    Minimum Programming Time Step1ms
    Edit ModeAdd, Delete, Import, Export
    Operation ModeRun, Stop, Cycle
    Trigger ModeAuto, Manual, External

    MEASUREMENT SPECIFICATIONS

    Voltage Accuracy±0.1% F.S.
    Voltage Resolution (V)0.001
    Current Accuracy±0.1% F.S.
    Current Resolution0.001
    Power Accuracy±0.2% F.S.
    Power Resolution0.001

    AC INPUT

    Wiring Code3pH+N+PE
    Frequency (Hz)47-63
    Voltage Range (V)380V±15%
    Power Factor0.99 @ Full-Load
    Efficiency>94%
    Harmonic Current≤3%

    MISCELLANEOUS

    Protection Functions
  • Input Protection: Over/Under Voltage, Over/Under Frequency, Phase Loss
  • Output Protection: Over Voltage/Over Current/Over Power, Internal Overtemperature, etc.
  • Communication Interfaces
  • Standard: LAN
  • Optional: RS485, CAN
  • External Interlock
  • External Interlock: NO/NC Input & Output
  • Trigger SignalsTrigger: Input/Output
    Control & DisplayLocal touchscreen control with remote PC monitoring
    Real-time display of voltage, current, power and operational trends
    Bleeder Resistor Cabinet:Safely dissipates energy under abnormal conditions to protect the DUT (Device Under Test)
    Capacitive Compensation ModuleCompresses voltage drop caused by cable impedance and reduces voltage ripple on the DUT
    Insulation & Withstand VoltageInsulation Resistance: 10 MΩ @ DC 500V; Withstand Voltage: 3600VAC (5000VDC) for 1 minute
    Cooling MethodForced air cooling
    Noise≤70dB
    Operating Temperature-10°C to +40°C
    Relative Humidity10% to 90% RH (non-condensing)
    Operating Altitude≤2000m

    Access our Download Center and Find Out Related Data Sheets

    From detailed integration manuals to the latest firmware, our Download Center provides the technical depth required for high-precision power electronics development. Enhance your ActionPower systems today.

    Access Download Center

    CONTACT US FOR YOUR BATTERY SIMULATOR

    Global Contact

    Sales Network & Locations

    If you are looking for an automated test system to validate your products during development and research stages to make sure of their successful commercial launch, ACTIONPOWER will be at your disposal to study your specifications and requirements to provided either standard or customized testing solutions.

    Join Our Network as a Distributor?

    Interested in ACTIONPOWER's testing solutions and equipment and want to promote them in your market? Contact us to joint our global sales network to grow together as partners.

    Quick Model Access

    Smart Discovery

    Access our Power Supply Wizard to find the right programmable power supply for your use cases and testing scenarios.

    discover programmable power supply by filtering with current, voltage and power ranges
    CONTACT US

    Contact Us

    Professionalism is what we care about. Why not email us with your technical requirements fully explained rather than submitting a simple message so that we revert more proactively with detailed solutions?

    Subscribe to Newsletter