Benefits of Bidirectional DC Power Supply
A bidireictional DC power supply can simulate a battery's functionality of charging and discharging as if in real world load and charging conditions as that of a EV vehicle pack.
Read the ArticleDeveloping component prototypes such as inverters for DERs like windturbine and solar farm or EV charging system, onboard chargers and V2G technology research, usually requires validating its reliability and stability in operation when connected with, as what will eventually happen in real world after their implementation, a high-voltage and high-power battery system. However, it is fundamentally unrealistic for any EV manufacturers and energy system integration companies to have at their disposition a real battery systems to which then can connect their products for validating, either for reasons of lack of controllability and the high cost. A battery simulator power supply is what you should rely on by contrast, to achieve better effectiveness and testing sequence automation.
TITAN Battery Simulator Power Supply, with legacy model name of ABS series, is a bidirectional power testing equipment that offers maximum level of 2000 VDC and offers parallel connection options for building testing platform with 10MW as maximum power rating of the same. The system's bidirectionality emulates a battery's operation pattern of both consuming and producing battery from one unit, further supported by smart built-in interfaces and remote softwares for users to configure at their discretion and emulate the required battery charging and discharging profile against their products, along side with versatile options for simulating batteries of various chemical compositions.

Technical resources in relation to the listed system and equipment
Product naming and model update record (for traceability)
This update reflects a series naming consolidation and model upgrade. Core battery simulation and emulation capabilities, including programmable voltage and current profiles, dynamic response, and application coverage, remain continuous across the product line. CE-certified versions of the TITAN Battery Simulator are now available for selected configurations, enabling compliant deployment in regulated laboratory and industrial testing environments beyond the scope of the former ABS series.
Find the right specification for your requirements
| Model | Power (kW) | Output Voltage (V) | Output Current (A) | Dimensions (mm) W × H × D |
|---|---|---|---|---|
| TD300-1K5-04 | ±300 | 20~1500 | ±400 | 2010×1955×1200 |
| TD400-1K5-06 | ±400 | 20~1500 | ±600 | 2010×1955×1200 |
| TD500-1K5-07 | ±500 | 20~1500 | ±700 | 2010×1955×1200 |
| TD600-1K5-08 | ±600 | 20~1500 | ±800 | 3410×1955×1200 |
| TD750-1K5-10 | ±750 | 20~1500 | ±1000 | 3410×1955×1200 |
Find the right specification for your requirements
| Model | Power (kW) | Max Voltage (V_DC) | Output Current (A) | Size (mm) | Weight(kg) |
|---|---|---|---|---|---|
| TD300-1K2-10 | ±300 | 12-1200 | ±1000 | 2010x1955x1200 | 2,640 |
| TD400-1K2-10 | ±400 | 12-1200 | ±1000 | 2010x1955x1200 | 2,850 |
| TD500-1K2-12 | ±500 | 12-1200 | ±1250 | 2010x1955x1200 | 3,020 |
| TD600-1K2-12 | ±600 | 12-1200 | ±1250 | 2410x1955x1200 | 3,500 |
| TD300-2K0-04 | ±300 | 20-2000 | ±400 | 1610x1955x1200 | 1,900 |
| TD400-2K0-06 | ±400 | 20-2000 | ±600 | 1610x1955x1200 | 2,430 |
| TD500-2K0-07 | ±500 | 20-2000 | ±700 | 2010x1955x1200 | 2,670 |
| TD600-2K0-08 | ±600 | 20-2000 | ±800 | 3410x1955x1200 | 3,500 |
| TD750-2K0-10 | ±750 | 20-2000 | ±1000 | 3410x1955x1200 | 4,390 |
| TD1K0-2K0-14 | ±1000 | 20-2000 | ±1400 | 3410x1955x1200 | 4,940 |
Designed for advanced battery-related test scenarios, the TITAN Battery Simulator provides seamless bidirectional operation to emulate real-world battery charge and discharge dynamics. During charging emulation, TITAN functions as a regenerative load, dynamically absorbing energy from chargers, inverters, or DC buses and returning it to the utility grid with an efficiency of up to 94%.
This capability is particularly critical in applications such as BMS algorithm validation, charger compliance testing, ESS cycling tests, and battery aging simulations. With an input power factor ≥ 0.99 and harmonic current below 3% of full scale, TITAN maintains low grid distortion even under continuous regenerative operation, ensuring stable, efficient, and environmentally responsible battery testing.
Explore more the advantages of regenerative load over resistive load
TITAN incorporates programmable internal resistance (Rint) emulation to model the non-linear and state-dependent behavior of real batteries. Engineers can define resistance characteristics as a function of SoC and SoH, allowing the simulator to reproduce dynamic voltage sag, current-dependent losses, and efficiency variations observed in real battery systems.
This functionality is critical for validating BMS control algorithms, charge termination logic, thermal management strategies, and protection thresholds under dynamic load conditions. By exposing chargers and control systems to realistic battery impedance behavior, TITAN enables more accurate, repeatable, and risk-free testing compared to physical batteries.
TITAN integrates software-defined battery chemistry models that reflect the distinct electrical characteristics of various battery types, including LFP, NCM/NCA, LCO, LMO, LTO, NiMH, and Lead-Acid systems. Users can parameterize each model with cell topology, SoC, temperature, and internal resistance to capture chemistry-specific voltage profiles and dynamic responses.
Supporting first-, second-, and third-order RC equivalent circuit models, TITAN enables advanced customization of battery behavior and allows user-defined models to be imported via CSV files. With a command update rate of up to 1 kHz, the simulator delivers fast transient response and closed-loop accuracy, making it ideal for developing and validating BMS algorithms, converters, and energy storage control systems.


TITAN delivers high dynamic performance to support validation of fast-changing battery operating conditions. Millisecond-level current rise, fall, and switching times allow engineers to test BMS control loops, protection thresholds, and charger response under abrupt load and mode transitions that cannot be reproduced by slow-response DC sources.
A voltage slew rate of up to 200 V/ms enables precise reproduction of rapid voltage transitions while maintaining controlled overshoot and undershoot. This capability is essential for evaluating system stability, transient robustness, and fault response in high-power battery simulation, converter development, and ESS testing environments.
| Dynamic Performance Parameter | Specification | Battery Simulation Test Scenario | Engineering Value in Use Cases |
|---|---|---|---|
| Current Rise Time (10% to 90%) | 2.4 ms | Step-load emulation in EV inverters, motor start-up simulation, sudden power demand changes in ESS converters | Enables accurate validation of BMS current control loops, overcurrent detection timing, and transient stability |
| Current Fall Time (90% to 10%) | 2.4 ms | Abrupt load removal, inverter shutdown, regenerative braking power handover | Verifies BMS response to rapid current decay, protection release logic, and system damping behavior |
| Current Switching Time (−90% to +90%) | 4.8 ms | Fast transition between discharge and charge modes, bidirectional DC/DC and inverter source–sink switching | Critical for validating bidirectional power flow control, charger handover stability, and DC bus regulation |
| Current Switching Time (+90% to −90%) | 4.8 ms | Transition from charging to discharging during regenerative braking or load reversal | Ensures realistic emulation of energy direction reversal and exposes potential control-loop oscillations |
| Voltage Overshoot During Sudden Load | 24 V (500 V applied) | Sudden high-current load connection, contactor closing, inverter step-load events | Allows precise verification of overvoltage thresholds, transient voltage tolerance, and protection margins |
| Voltage Undershoot During Sudden Load Removal | 22 V (500 V removed) | Abrupt load disconnection, inverter or converter shutdown | Supports validation of undervoltage detection, ride-through capability, and system stability |
| Voltage Transition Time at 200 V/ms | 2.04 ms (136 V → 536 V) | Rapid DC bus voltage change, multi-voltage platform switching, abnormal condition injection | Enables aggressive dynamic testing of power electronics, insulation margins, and fast-reacting control algorithms |
TITAN enables high-power battery simulation through parallel connection of multiple units, scaling system capacity up to 10 MW without compromising communication integrity or dynamic performance. Each unit operates under synchronized control to ensure uniform current sharing and coordinated transient response.
This capability is essential for multi-channel test benches, parallel charger testing, and large-scale ESS simulations, where mismatched dynamics between paralleled sources can lead to unstable behavior or inaccurate test results. TITAN’s parallel architecture preserves fast response and control accuracy at MW power levels.

Electric vehicle powertrains impose highly dynamic and bidirectional electrical stress on the battery interface during acceleration, regenerative braking, and torque transients. Accurate validation of traction inverters, onboard chargers (OBC), and high-voltage DC/DC converters therefore requires a battery emulator capable of fast current reversal, controlled voltage dynamics, and repeatable transient behavior, without becoming the limiting factor in the test loop.
TITAN delivers bidirectional source–sink operation with high dynamic performance, supporting voltage swing rates up to 200 V/ms and current change rates up to 500 A/ms. Typical current rise times of ≤ 2.0 ms (10–90%) and polarity switching within ≤ 4 ms (–90% ↔ +90%) enable realistic reproduction of traction and regenerative events. With CE-certified output ranges covering 20–1500 VDC and single-unit power blocks from 300 kW to 750 kW, expandable through parallel operation, the platform supports both component-level and system-level EV validation, without the safety and repeatability limitations of real battery packs.
Typical DUTs
Relevant standards and guidelines


EV charging systems and vehicle-to-everything (V2X) power interfaces operate against a battery interface with continuously changing voltage, current, and impedance during charging, discharging, and bidirectional power exchange. When the battery is treated as an ideal load or source, charging instability, current oscillation, and protection miscoordination are often masked in laboratory tests. TITAN provides a realistic and repeatable battery-side electrical environment for EV charging and V2X validation, supporting high-voltage DC output up to 1500 VDC (CE configurations), scalable power blocks from 300 kW to 750 kW, and fast voltage and current dynamics (200 V/ms, 500 A/ms). Configurable battery models and bidirectional source–sink operation enable accurate verification of control stability, power reversal behavior, and protection coordination without external loads.
BESS and PCS operate across wide voltage ranges and continuously alternate between charging and discharging modes. Validation requires battery emulation that can reproduce steady-state operation, rapid load steps, and abnormal conditions under deterministic and repeatable control, while supporting long-duration cycling at high power.
TITAN platform supports configurable battery models with programmable parallel configuration, initial SOC, temperature, internal resistance, and capacity, including 1st-, 2nd-, and 3rd-order RC equivalent models and CSV-based profile import. Scalable high-power output combined with regenerative power sinking allows efficient execution of charge/discharge cycles while returning absorbed energy to the grid, significantly reducing thermal stress and energy consumption during extended tests. Measurement accuracy of ±0.1% F.S. for voltage and current and ±0.2% F.S. for power, with 0.001 resolution, provides a consistent basis for efficiency and dynamic performance evaluation.


Modern AI data centers increasingly rely on high-power DC architectures, including UPS systems, battery-backed DC buses, and energy buffering subsystems, to support rapidly varying computational loads. Validation focuses on ride-through behavior, recharge sequences, fast load transients, and protection coordination, often under long-duration operating conditions.
The bidirectional source-sink capability of TITAN is suitable for UPS battery interfaces and DC-side energy buffers. Voltage dynamics up to 200 V/ms, current change rates up to 500 A/ms, and scalable high-power output (300–750 kW per unit, expandable via parallel operation) support realistic simulation of load steps and power reversals. Regenerative energy feedback significantly reduces operating cost during endurance and recharge testing in data-center validation environments.
The following specifications are subject to modifications and changes without notification in advance. All specifications measured are at product's maximum ratings, if not otherwise noted.
| Output Modes | Constant Voltage (CV), Constant Current (CC), Constant Power (CP), Programmable Output, and PV Standards (EN50530/Sandia) for Static and Dynamic MPPT Tracking and Solar Array Simulation |
|---|---|
| Energy Regeneration | Power sinking and regenerative feedback to grid |
| Electrical Isolation | Input/Output Electrical Isolation |
| Parallel Operation Capability | Multiple Units of the Same Model Can Be Parallelled |
| VOLTAGE | |
|---|---|
| Setting Resolution | 0.01 |
| Accuracy | ±0.1 F.S. |
| RMS Ripple | 0.1% F.S. (Resistive Load) |
| Voltage Swing Rate | 200V/ms |
| CURRENT | |
|---|---|
| Setting Resolution | 0.01 |
| Accuracy | ±0.1% F.S. |
| RMS Ripple | 0.1% F.S. (Resistive Load) |
| Changing Rate | 500A/ms |
| Rise Time | ≤2.0ms (10%-90% @ rated current) |
| Switching Time | ≤4ms (between -90% and +90%) |
| Peak Time | 60s (1200VDC) |
| BATTERY SIMULATION | |
|---|---|
| Battery type | Supports simulation of various battery chemistries, including: |
| Configurable Parameters | Series & parallel cell count, Initial SOC (State of Charge), Initial temperature, Internal resistance, Cell capacity |
| Interface | Supports CSV import for custom models |
| Real-Time Performance | 1ms command update rate for high-speed dynamic simulation |
| UNIVERSAL PROGRAMMING FUNCTIONS | |
|---|---|
| Programming Steps | 200 steps |
| Programming Parameters | Voltage/Current, Rise Time, Hold Time, Trigger Pulse Output |
| Rise Time Range | 1ms ~ 99999s |
| Flat Top Time Range | 1ms ~ 99999s |
| Minimum Programming Time Step | 1ms |
| Edit Mode | Add, Delete, Import, Export |
| Operation Mode | Run, Stop, Cycle |
| Trigger Mode | Auto, Manual, External |
| Voltage Accuracy | ±0.1% F.S. |
|---|---|
| Voltage Resolution (V) | 0.001 |
| Current Accuracy | ±0.1% F.S. |
| Current Resolution | 0.001 |
| Power Accuracy | ±0.2% F.S. |
| Power Resolution | 0.001 |
| Wiring Code | 3pH+N+PE |
|---|---|
| Frequency (Hz) | 47-63 |
| Voltage Range (V) | 380V±15% |
| Power Factor | 0.99 @ Full-Load |
| Efficiency | >94% |
| Harmonic Current | ≤3% |
| Protection Functions | |
|---|---|
| Communication Interfaces | |
| External Interlock | |
| Trigger Signals | Trigger: Input/Output |
| Control & Display | Local touchscreen control with remote PC monitoring Real-time display of voltage, current, power and operational trends |
| Bleeder Resistor Cabinet: | Safely dissipates energy under abnormal conditions to protect the DUT (Device Under Test) |
| Capacitive Compensation Module | Compresses voltage drop caused by cable impedance and reduces voltage ripple on the DUT |
| Insulation & Withstand Voltage | Insulation Resistance: 10 MΩ @ DC 500V; Withstand Voltage: 3600VAC (5000VDC) for 1 minute |
| Cooling Method | Forced air cooling |
| Noise | ≤70dB |
| Operating Temperature | -10°C to +40°C |
| Relative Humidity | 10% to 90% RH (non-condensing) |
| Operating Altitude | ≤2000m |
From detailed integration manuals to the latest firmware, our Download Center provides the technical depth required for high-precision power electronics development. Enhance your ActionPower systems today.

A bidireictional DC power supply can simulate a battery's functionality of charging and discharging as if in real world load and charging conditions as that of a EV vehicle pack.
Read the Article
State-of-Charge (SOC) and State-of-Health (SOH) are key metrics for evaluating and revealing an EV battery's status throughout its life span. Discover how these metrics are measured with the participation of BMS.
Discover more Details
Discover the development of EV charging technology and how ActionPower's battery simulator drives your innovations ahead with flexible battery emulation capabilities.
Read More
Leverage your testing efficiency when it comes to DC electronic loading by deploying a bidirectional DC power supply. Discover the benefits of regenerative load technology.
Read More
If you are looking for an automated test system to validate your products during development and research stages to make sure of their successful commercial launch, ACTIONPOWER will be at your disposal to study your specifications and requirements to provided either standard or customized testing solutions.
Interested in ACTIONPOWER's testing solutions and equipment and want to promote them in your market? Contact us to joint our global sales network to grow together as partners.
Professionalism is what we care about. Why not email us with your technical requirements fully explained rather than submitting a simple message so that we revert more proactively with detailed solutions?