POWERPEDIA
All about power electronics
Slew Rate
Slew rate in the context of an electronic load refers to the maximum rate of change of the load current when stepping from one setpoint to another. It is typically expressed in amperes per microsecond (A/µs) or amperes per millisecond (A/ms).

Definition of Slew Rate
In the context of programmable power supplies and electronic loads, slew rate is the maximum rate of change of voltage or current with respect to time. It describes how quickly an instrument can transition from one setpoint to another and is typically expressed as V/μs (voltage slew rate) or A/μs (current slew rate).
Mathematical expression (voltage or current):
$$
SR = \frac{dX}{dt} \quad \text{where } X \in \{V, I\}
$$
Significance in Power Testing
Programmable Power Supplies
- The voltage slew rate defines the ramp-up/down speed between setpoints.
- Helps prevent overshoot and stress on the DUT during startup and transient simulations.
- Example time estimate:
\(t = \frac{\Delta V}{SR}\)
e.g., ramping \(0 \to 400\,\text{V}\) at \(1\,\text{V}/\mu\text{s}\) takes
\(t = \frac{400\,\text{V}}{1\,\text{V}/\mu\text{s}} = 400\,\mu\text{s}\).
Electronic Loads (DC)
- Configurable rising and falling current slew rates reproduce realistic load steps.
- Used for transient response tests, battery discharge pulses, EV/OBC/DC-DC behavior, and server power bursts.
- Too low: cannot emulate real dynamics; too high: may exceed DUT capability and trigger protections.