Home Contact EN

POWERPEDIA

All about power electronics

Regenerative Grid Simulator

A regenerative grid simulator is a programmable AC power system that emulates grid conditions while enabling bidirectional energy flow for realistic and efficient grid compliance testing.

regenerative grid simulator by ActionPower

Technical Definition of Regenerative Grid Simulator

Remarked functionally as one of the key advantages of regenerative load, a regenerative grid simulator is in nature a programmable advanced 3-phase AC power supply (with controlled load capability) for replicating and approximating the electrical behaviour of a real power grid during sinking and sourcing conditions (alternatively referred to as the four-quadrant operation capability). Primarily applied for laboratory testing and end-of-line manufacturing validation, a regenerative grid simulator compounds with electrical methods and emulates abnormal 3-phase AC power conditions such as voltage and frequency changes, phase deviation, impedance, fault ride-through and disturbances as if a real grid with anomalies.

Product showcase of the ACTION POWER Regenerative Grid Simulator. The right side features two white, floor-standing industrial cabinets of different sizes with control panels and ventilation grilles. The bottom left includes three oscilloscope waveform screenshots, illustrating the equipment's ability to simulate various complex AC grid fluctuations and anomalies.

With the bidirectional power flow and four-quadrant coverage, the Regenerative Active Front End (AFE) refeeds the power back to grid or DC bus for recovering the energy – a distinct advantage when applied for testing of PCS, grid-tied inverters and EVSE charging and V2G conformance to reduce thermal stress, achieve improved cost-effectiveness and sustainable long-run operation at high-power rating.

Functional Principles and What to Emulate with Regenerative Grid Simulators

A hierarchy of emulation capabilities as below addresses the question about “what to replicate” with a regenerative grid simulator. The diagram is depicted following the level of complexity about the testing scenario, scaling up from offering just a simply stable-state AC source until complex and dynamic testing applications.

Hardware and Software of Regenerative Grid Simulator’s Functional Architecture

A regenerative grid simulator, when operating in sourcing mode, receive the mains supply from local utility which is originally in three-phase AC form where disturbances. The original AC power goes through several stages before it is processed into a controlled and programmed output. While when it runs in sinking mode, the process of power flow is vice versa. Both directions of power flow is supported, apart from hardware control loops, as well as software control methods.

Hardwares and Power Stages: AFE, DC Link, Inverter

A typical two-stage architecture is adopted by regenerative grid simulator which consists of an Active Front End (AFE), a shared DC link, and a grid-forming inverter stage.

  • Active Front End (AFE): The AFE interfaces with the utility grid and performs controlled AC/DC conversion with four-quadrant operation, maintaining a regulated DC link voltage while returning energy injected by the DUT back to the grid. It defines the regenerative capability and grid-side power quality of the system.
  • DC Link:  The DC link acts as an energy buffer and decoupling node between the grid-facing AFE and the output inverter. Its voltage level constrains the maximum AC output, while its stored energy determines the system’s ability to support fast transients and fault events.
  • Grid-Forming Inverter: The grid-forming inverter synthesises programmable three-phase AC voltages and dynamically presents grid characteristics such as impedance, unbalance, disturbances, and fault conditions. Its current capability and control bandwidth govern the fidelity of weak-grid and ride-through emulation.

Software and Control Stack Architecture

While the AFE DC link and grid-forming inverter define the physical capability of a regenerative grid simulator, it is the software and control stack that determines how these hardware blocks behave with pattern similar to the electrical characteristics of a grid.. On top of the power stage, a layered control architecture translates hardware capability into programmable waveforms, grid impedance behaviour, test events and sequences, and protection boundaries. The below displayed diagram is another hierarchy architecture from the software perspective.

The Advantages of Regenerative Capability for Grid Simulator

Power flow activities in real grid in not uni-directional but with towards and backs between DERs and user-ends. A testing scenario with grid simulation in either laboratory or manufacturing end-of-line is thus supposed to comply with such a pattern, and that is from which the essentialness of regenerative load is addressed.

Energy Consumption and Thermal Management for Long-Run High-Power Operation

Heat dissipation suggests a huge challenge for thermal management for a test bench or laboratory, especially when it comes to higher power testing scenarios. Supposing a non-regenerative system running at 750kw full power for grid load simulation, the heat generated respectively will be a disaster. A regenerative grid simulator is thus a system developed to handle such a drawback of conventional load bank for reducing thermal stress.

To Accommodate Energy Fed from EUTs Which are Usually Source of Power

Grid-tied devices from DERs systems whose component include photovoltaic inverters, power conversion systems are often a source of power that supports local utility with generated energy. Testing these EUTs thus require proper methods for processing the same to achieve sustainable, stable, and economic testing processes.

Realistic Grid-Connectedness and Grid Interoperability

Interoperability that happens in a real electrical grid system is far more complex and compound than a simple circumstance with bidirectional AC power flow. Advantages offered by  grid simulators include stronger current response, energy buffering, reproducible and realistic testing applications for weak-grid conditions and fault ride-through.

Laboratory Setup and Additional Equipment Concerns

Building up a laboratory is prevailed by deliberate design of infrastructure including cooling and mains supply selection. Regenerative grid simulator reduces often to under 5% of the full test rating by recycling energy. Nevertheless, control and protection are further to concern beyond infrastructure as mandated by standards such as IEEE 1547 and IEC 62116 about grid codes for EUTs.


Ultimate high-power grid simulator with parallel master-slave connection capability for reaching 10 MVA power while uncompromising the performance and dynamics of the whole system. TITAN AC power grid simulator is among the most powerful, functional and flexible grid emulation systems on the market.

Discover TITAN Regenerative Grid Simulator

Promotional banner for the TITAN Regenerative Grid Simulator featuring a dark background with glowing blue lines. Two large white industrial cabinets are displayed on the right. The left side lists key specifications: 860 VAC @ L-N Max. Output Voltage, 10 MVA Max. Output AC Power, and Comprehensive Grid Emulation Capability.

Typical Testing Applications of Regenerative Grid Simulator and Testing Topologies

PV inverters and PCS are the most representative use cases for regenerative grid simulators, as the DUT typically operates in continuous power injection mode. Testing focuses on weak-grid conditions, grid impedance interaction, fault ride-through behaviour, anti-islanding protection as per IEEE 1547 and other protection response under abnormal voltage events.

Test system topology diagram for a PV Inverter or PCS. On the left, a TITAN Series Solar Array Simulator (SAS) provides DC input, with an orange box highlighting '2000 VDC Solar Array Simulation' and '10 MW High Power Capability'. The center shows the Device Under Test (comprising DC-DC Inverters, a DC Link, and a DC-AC Inverter). The AC output connects to a TITAN Series Regenerative Grid Simulator on the right, with a blue box highlighting '10 MVA Grid Emulation' and 'Integrated RLC Load Circuit'. At the top, Measuring Instruments monitor data across the system. The bottom displays four SAS software modes: SAS Mode, Table Mode, Shadow Mode, and List Mode.
PCS and Inverter Testing Topology with Regenerative Grid Simulator – Often for IEEE, UL and IEC Standards Validation

EVSE, on-board chargers, and V2G systems involve bidirectional power flow and frequent operating mode transitions. Typical tests address voltage and frequency disturbances, phase unbalance, fault injection, and control stability during dynamic grid events.

Topology diagram for an EV charger testing system. On the right, a TITAN Series High-Power Regenerative Grid Simulator provides an INPUT current, with a blue box highlighting 'Software and Testing Automation, Grid Anomaly and Disturbances'. In the center are the EV Chargers under test. On the left, a TITAN Series EV Battery Simulator receives the 'Charge' current, with an orange box highlighting 'Battery Simulation Software, Regenerative Load Function'.
Grid Simulators in Charging Safety Testing Scenario for Validating EVSE Conformance, Related to IEC 61851

UPS systems and microgrid controllers primarily require validation of grid behaviour rather than sustained power injection. Testing emphasises grid event handling, load step response, and transitions between grid-connected and islanding operation using a programmable reference grid.

Comprehensive test architecture diagram for an Uninterruptible Power Supply (UPS). The central UPS receives AC input from a TITAN Series MVA Grid Simulator on the left, featuring 'Grid Outage Injection'. On top, a Battery Simulator Power Supply handles DC interaction, featuring dynamic SOC and internal resistance emulation. On the right, a Regenerative AC Load Simulator receives the AC output. Dashed lines indicate both the battery and load simulators can regenerate energy back to the Utility Grid.
Regenerative Grid Simulator Forces Grid Outage to Perform UPS Switching Capability for AI Data Center

Quick Model Access

Smart Discovery

Access our Power Supply Wizard to find the right programmable power supply for your use cases and testing scenarios.

discover programmable power supply by filtering with current, voltage and power ranges
CONTACT US

Contact Us

Professionalism is what we care about. Why not email us with your technical requirements fully explained rather than submitting a simple message so that we revert more proactively with detailed solutions?

Subscribe to Newsletter

Thank you for subscribing!