POWERPEDIA
All about power electronics
Arrhenius Reliability Model
The Arrhenius reliability model is a mathematical model that describes the relationship between temperature and failure rate, used to predict the lifetime of electronic components under accelerated stress conditions.

Definition
The Arrhenius reliability model describes the relationship between temperature and the failure rate of electronic components. Originating from the chemical Arrhenius equation, it assumes that higher temperatures accelerate physical and chemical degradation processes, thereby increasing the rate of failure.
Mathematical Expression
The model is commonly expressed as:
\(
\lambda = A \cdot e^{-\frac{E_a}{kT}}
\)
- \(\lambda\): failure rate
- \(A\): pre-exponential factor or acceleration constant
- \(E_a\): activation energy
- \(k\): Boltzmann constant
- \(T\): absolute temperature in Kelvin
Engineering Significance
In power electronics and reliability testing, the Arrhenius model is used to calculate the acceleration factor (AF) that correlates stress test conditions with normal use conditions. This enables engineers to predict long-term reliability through short-term high-temperature or burn-in tests, reducing development time and improving confidence in design robustness.
Accelerated Life Prediction
The acceleration factor is usually defined as:
\[
AF = \exp\!\left(\frac{E_a}{k}\left(\frac{1}{T_{\text{use}}} – \frac{1}{T_{\text{stress}}}\right)\right)
\]
Here, \(T_{\text{stress}}\) is the stress (test) temperature and \(T_{\text{use}}\) is the normal operating temperature. For example, if AF = 100, one hour of testing under stress conditions is equivalent to 100 hours of real-world operation in terms of failure occurrence.
Typical Use Cases
- Reliability verification of power modules and inverters
- Lifetime assessment of IGBT, MOSFET, and other power semiconductors
- High-temperature stress testing for automotive OBC and BMS systems
- Accelerated ageing of DC/DC and AC/DC converters
- Burn-in and screening of electronic components before shipment
Limitations and Considerations
The Arrhenius model applies primarily to thermally activated failure mechanisms such as chemical degradation, diffusion, or interfacial reactions. For failures driven by mechanical, electrical, or multi-factor stresses, the model alone may not be sufficient. Selecting the correct activation energy and validating the model against experimental data are essential to achieving accurate life prediction.