Home Contact EN

POWERPEDIA

All about power electronics

Arrhenius Reliability Model 

The Arrhenius reliability model is a mathematical model that describes the relationship between temperature and failure rate, used to predict the lifetime of electronic components under accelerated stress conditions.

Arrhenius reliability model

Definition

The Arrhenius reliability model describes the relationship between temperature and the failure rate of electronic components. Originating from the chemical Arrhenius equation, it assumes that higher temperatures accelerate physical and chemical degradation processes, thereby increasing the rate of failure.

Mathematical Expression

The model is commonly expressed as:

\(
\lambda = A \cdot e^{-\frac{E_a}{kT}}
\)

  • \(\lambda\): failure rate
  • \(A\): pre-exponential factor or acceleration constant
  • \(E_a\): activation energy
  • \(k\): Boltzmann constant
  • \(T\): absolute temperature in Kelvin

Engineering Significance

In power electronics and reliability testing, the Arrhenius model is used to calculate the acceleration factor (AF) that correlates stress test conditions with normal use conditions. This enables engineers to predict long-term reliability through short-term high-temperature or burn-in tests, reducing development time and improving confidence in design robustness.

Accelerated Life Prediction

The acceleration factor is usually defined as:

\[
AF = \exp\!\left(\frac{E_a}{k}\left(\frac{1}{T_{\text{use}}} – \frac{1}{T_{\text{stress}}}\right)\right)
\]

Here, \(T_{\text{stress}}\) is the stress (test) temperature and \(T_{\text{use}}\) is the normal operating temperature. For example, if AF = 100, one hour of testing under stress conditions is equivalent to 100 hours of real-world operation in terms of failure occurrence.

Typical Use Cases

  • Reliability verification of power modules and inverters
  • Lifetime assessment of IGBT, MOSFET, and other power semiconductors
  • High-temperature stress testing for automotive OBC and BMS systems
  • Accelerated ageing of DC/DC and AC/DC converters
  • Burn-in and screening of electronic components before shipment

Limitations and Considerations

The Arrhenius model applies primarily to thermally activated failure mechanisms such as chemical degradation, diffusion, or interfacial reactions. For failures driven by mechanical, electrical, or multi-factor stresses, the model alone may not be sufficient. Selecting the correct activation energy and validating the model against experimental data are essential to achieving accurate life prediction.

Quick Model Access

Smart Discovery

Access our Power Supply Wizard to find the right programmable power supply for your use cases and testing scenarios.

discover programmable power supply by filtering with current, voltage and power ranges
CONTACT US

Contact Us

Professionalism is what we care about. Why not email us with your technical requirements fully explained rather than submitting a simple message so that we revert more proactively with detailed solutions?

Subscribe to Newsletter

Thank you for subscribing!