Home Contact EN

Power Electronics Calculators

Discover and take advantages of online calculation tools developed by ActionPower to drive your innovations ahead - all for power electronics

06-November-2025 Author: Zhiwei Bao

RLC Impedance Calculator



What is an RLC Circuit?

The terminology of "RLC Circuit" derives from the composition of a certain kind of circuit where "resistor", “inductor” and "capacitor" are present, and connected either parallel or series topology. Its name derives from the initials of each of these three key components where, respectively, with R standing for resistor, L representing inductor, and C for capacitor. Modern power electronics and circuit designing combine RLC circuits with miscellaneous elements, examples of which include transistor and diodes, to form integrated circuits or IC. [1] Such is a typical application of RLC circuit which functions along the circuit as filters, amplifiers, and oscillators, replying on its resonances and damping characteristics. RLC circuits are referred to as second-order circuits, attributing to which is the use of second-order differential equations [2] within these circuits for purpose of regulating voltages and currents.

Explanations to Inductance, Capacitance, Reactance, Resistance

Inductance, Capacitance, Reactance, and Resistance are four fundamental electrical concepts that describe how different components in an electrical circuit behave when exposed to voltage and current, particularly in Alternating Current (AC) circuits.

Calculation of RLC Impedance in Series: Formulas, Visualization

One would be familiar with the calculator of overall resistance of a circuit in the event that they are connected in series, for example, as simple as the equation and the circuit diagram as below:

resistor in series

\( R = R_1 + R_2 + R_3 + R_4 \)

However, the question is - would the calculation and equation still be the simple sum what if the components connected in series are those what compose an RLC circuit?

RLC circuit topology

\( Z = R + X_L+ X_C \quad \ \text{(Is this equation still correct?)} \)

While a purely resistive circuit consists solely of resistors connected in series or parallel, the moment components like capacitors or inductors are introduced, the circuit becomes reactive due to the presence of measurable reactance. Reactance, as the combined result of inductance and capacitance, takes more factors into concern compared to resistance, which are:
  • The frequency of the AC source that determines the reactive components' contribution to the circuit's total impedance
  • The degree to which the voltage and current waveforms are out of phase due to the energy storage effect of the reactive components
The calculation of RLC circuit's impedance can be depicted through a Complex Cartesian System or Complex plan as below.

Impedance calculation in complex cortesian coordination system

An RLC circuit combines three elements — Resistance (R), Inductance (L), and Capacitance (C). The impedance \(Z\) describes how the circuit resists alternating current, considering both resistive and reactive effects. The phasor diagram visually represents this relationship, where the horizontal axis corresponds to the real part (R), and the vertical axis to the imaginary part (X). Inductive and capacitive reactances are defined as:

\[ X_L = \omega L, \quad X_C = \frac{1}{\omega C} \]

The net reactance and complex impedance are:

\[ X = X_L - X_C, \quad Z = R + jX \]

The magnitude and phase angle of impedance:

\[ |Z| = \sqrt{R^2 + (X_L - X_C)^2}, \quad \tan\theta = \frac{X_L - X_C}{R} \]

Among all above equations, each of the symbols refer to the below concepts:
  • \( R \): Resistance (ohms, Ω), representing real power loss.
  • \( L \): Inductance (henries, H), causing voltage to lead current.
  • \( C \): Capacitance (farads, F), causing current to lead voltage.
  • \( \omega = 2\pi f \): Angular frequency (radians per second).
  • \( X_L \): Inductive reactance, increases with frequency.
  • \( X_C \): Capacitive reactance, decreases with frequency.
  • \( X \): Net reactance, the difference \( X_L - X_C \).
  • \( j \): Imaginary unit (\( \sqrt{-1} \)), representing phase shift.
  • \( \theta \): Phase angle between voltage and current.
The relation between the inductance and capacitance would also affect the characteristics of the circuit,
  • If \( X_L > X_C \): circuit is inductive — voltage leads current.
  • If \( X_C > X_L \): circuit is capacitive — current leads voltage.
  • If \( X_L = X_C \): circuit is resonant — impedance is purely resistive (\( Z = R \)).

Calculation of RLC Impedance in Parallel: Formulas, Visualization

In a parallel RLC circuit, the resistor \(R\), inductor \(L\), and capacitor \(C\) are connected in parallel. The voltage across each component is the same, while the total current is the sum of the currents through each branch. The calculation carries out fundamentally on the concept of admittance \(Y\). For parallel circuits, it is more intuitive to use admittance \(Y\), which is the reciprocal of impedance \(Z\). The total admittance is:

\[ Y = Y_R + Y_L + Y_C = \frac{1}{R} + j \left( \omega C - \frac{1}{\omega L} \right) \]

Where:
  • \(\frac{1}{R}\) represents the real part of the resistor branch admittance.
  • \(j \omega C\) represents the capacitive branch reactance in admittance form, varying with angular frequency \(\omega\).
  • \(j \left(-\frac{1}{\omega L}\right)\) represents the inductive branch reactance in admittance form.
The impedance is the reciprocal of the admittance:

\[ Z = \frac{1}{Y} \]

The magnitude of admittance is:

\[ |Y| = \sqrt{ \frac{1}{R^2} + \left( \omega C - \frac{1}{\omega L} \right)^2 } \]

Therefore, the magnitude of impedance is:

\[ |Z| = \frac{1}{|Y|} = \frac{1}{ \sqrt{ \frac{1}{R^2} + \left( \omega C - \frac{1}{\omega L} \right)^2 } } \]

Resonant Frequency Characteristics

At resonance, the reactances of the inductor and capacitor cancel each other out:

\[ \omega C - \frac{1}{\omega L} = 0 \]

At the resonant frequency \(f_0\):
  • The impedance magnitude \(|Z|\) reaches its maximum, because the admittance is minimized.
  • The total current \(|I| = Y \cdot V\) is minimum, since \(Y\) is at its lowest.

Additional Readings

RLC modeling is a key functions for grid-adaptability testing scenario where the EUT's performance is validated with different emulated grid impedance and approximated by a programmable power system's FPGA-controlled hardwares and programming softwares. Read: How Do Grid Simulator Approximate Real-World Grid Impedance with FPGA-Based RLC Modeling? for more information.

Migrate Calculation to Real Testing Scenario

ActionPower's grid simulator is integrated with FPGA-based RLC modeling for emulating real world grid impedance for validating EUT's performance and response agasint varying operating conditions.

Check TITAN Regenerative Grid Simulator

TITAN Series High Power AC Grid Simulator
Quick Model Access

Smart Discovery

Access our Power Supply Wizard to find the right programmable power supply for your use cases and testing scenarios.

discover programmable power supply by filtering with current, voltage and power ranges
CONTACT US

Contact Us

Professionalism is what we care about. Why not email us with your technical requirements fully explained rather than submitting a simple message so that we revert more proactively with detailed solutions?

Subscribe to Newsletter

Thank you for subscribing!