Find out the latest innovations from ActionPower
All kinds of solar energy generation systems, despite their form of implementation as either house-hold solar panels or those more advanced arrays installed on a space satellite, share the same goal of extracting the maximum power as possible from the variant irradiance conditions as if what is born with the so-called lean mindset. [1]
While it is not the solar module itself the technologies are used to control its operation condition yet instead against the control algorithms of inverter that optimizes the power conversion efficiency, the underlying key approach to achieving the goal mentioned previously is about the validation of the latter. And further more concerns are to bear in mind when it scales up to utility-level where these photovoltaic systems operate as DERs and connected to the grid, for which interoperability implies more potential unwanted scenarios, risks arising from which should be mitigated. [2]
SAS (Solar Array Simulator) is thus the testing instruments applied for this validation purposes to boost, by optimizing intermediarily the effectiveness of those “conversion gateways”, the operational efficiency of the photovoltaic systems. This article provides insights into this specific programmable DC power source variant, their different forms of system architecture and to be referred to as a selection guide to support your test bench setup.
The first question to answer before detailed engineering explanations are provided with regard to our topic is to differentia, to strictly the functional extent, a programmable DC source and a specific programmable source for photovoltaic (PV) emulation. Or to put it alternative, what are the differences between a DC power supply and PV simulator.
In nature, the power generation process within the solar cell is not indeed a DC source, but a non-linear, condition-dependent process whose electrical behaviour continuous changes against external factors including irradiance, temperature, topology, and control interaction. By contrast, a simply DC programmable source, though with capability of defining voltage and current as per user requirements, cannot replicate these dynamics upto hype.
A DC power source may regulate its output rigorously within its defined power boundaries on the I–V plane; however, the electrical behaviour of a photovoltaic module, when plotted on the same plane, is inherently non-linear. As a consequence, the operating point of a photovoltaic module is not imposed by the source itself, but continuously emerges from its interaction with the downstream power electronics.

Fig 1. P-V characteristics at various temperature and solar irradiance
Variations in irradiance, temperature, and control perturbations introduced by MPPT algorithms constantly reshape the effective I–V characteristic seen by the inverter. [3] A conventional DC power source, governed by stiff regulation and instantaneous response, lacks the dynamic impedance and curve migration required to reflect this interaction, and therefore remains limited in replicating realistic photovoltaic behaviour under dynamic test conditions.
Apart from that, a normal programmable DC power source is inherently compromised in functionality and becomes increasingly limited when applied to more complex testing scenarios.
A key question to consider is whether such a DC power source is capable of reacting when a closed-loop architecture is established downstream, where the power generated by the inverter is absorbed by a regenerative grid simulator, analysed in terms of power quality and dynamic behaviour, and where the resulting information is fed back to the upstream stage to form a Power-Hardware-in-the-Loop (PHIL) process. Yet this is not the key technical details we have to cover in this article, only to indicate the differences between the two kinds of systems.

Fig 2. Power Hardware-in-the-Loop (PHIL) Testing Scenarios Examples
Understanding the photovoltaic system’s feature that it is a hierarchically composed structure that it is in nature a scalable construction levels up from an individual modules until an aggregated facility, from a power-electronics and testing perspective, is essential for understanding and selecting appropriate PV simulation platform and validation technologies. A skip the most basic level of solar cell and instead, set out from panel and modules towards array composition.

Fig 3. Hierarchical Composition of Solar System
Solar panel and solar module represent a single generate unit usually composed from series- and parallel-connected solar cells within a single mechanical farm, with its power rating typically spanning from 300W to 750W for modern commercial use and dependent on cell technology and form factor.
A photovoltaic string is formed by connecting multiple panels in series, increasing the operating voltage while maintaining the same current. Depending on the number of modules per string, the resulting power typically spans 5 kW to 30 kW, with DC voltages commonly reaching 600–1100 V.
At the highest structural level, multiple strings are combined—typically through DC combiner boxes—into a photovoltaic array. Array-level power ratings start from tens of kilowatts and scale to hundreds of kilowatts or megawatts, as seen in commercial rooftops and utility-scale solar plants.
Some “critiques” on the limitation of a bare DC power source were stated in the previous context though, we did not clarify what should be instead the power testing instrument to opt for.
In the power testing industry, an ambivalence exists admittedly that the terminology of SAS (Solar Array Simulator) actually does not only refer to a programmable power that emulates the behaviours of solar arrays whose power is of hundred of kW and until even MW, however, the same term is also used for those lower power of a few kWs testing scenarios where a lower power PV simulator is used. For this part we will not specifically denote intentionally their differences, but to follow the commonsense to call them undifferentiated as SAS power supplies.
The main function of an SAS (Solar Array Simulator) is to replicate, with program-controlled- and defined- DC output, the shifting and dynamic behaviours of photovoltaic systems, let it to be low power solar panel or larger facility of solar array systems. Or say, for the following functional definition we don’t differentiate solar cell simulators, panel simulators or array simulators.

Fig 4. SAS (Solar Array Simulators) by ActionPower
SAS offers points-based setting on the Cartesian plane for representing complete non-linear I-V curve for dynamic replication, with the output calculated as a function of the terminal voltage.
The P-V characteristics, subsequently following this approach, emerge from the model source behaviour to emulate realistic operating-point movement under inverter control perturbations for evaluating MPPT tracking behaviour, convergence dynamics, and operating stability.
SAS power supplies are programmable for setting internal resistance which is a key factor of real solar module that dictates efficiency, power output, and heat generation, lowering fill factor.
Module- and string-level resistance emulation conducted from SAS supports more realistic and effective PV behaviour replication. An SAS incorporates this behaviour through programmable internal resistance (Rint) and module- or string-level resistance emulation under various operating conditions.
Solar Array Simulators are designed to support photovoltaic performance evaluation standards that define dynamic test methodologies rather than static operating points. Typical support includes:
Standardized MPPT efficiency evaluation and compliance-oriented testing are streamlined by standard-referring repeatable PV behaviour modelling.
Each testing scenarios has their own specific power rating requirements considering that micro-inveters, string-inverters and central inverters are targeted for converting solar energy from different level of PV systems and even DER-connected assets. Respectively the testing application for the latter requires different programmable sources to be implemented.
Testing scenarios where micro-inverters or lower-power hybrid inverters are to be validated with a emulated solar panel or solar module can be matched with the implementation of solar panel/module simulator of modular and rack-mount sources, typically of 3U size and available for setting up within rack like 19-U or 42-U per IEC 60297. [4]
They are primarily targeted for R&D laboratories where frequent reconfiguration is required and testing use cases are for panel-level and string-level inverter validation, for which it suffices with just single or limited MPPT interaction and voltage of moderate DC, with power rate spanning from sub-kilowatt to tens of kilowatts. The CORTEX bidirectional DC power supply is an example of such system with capability of simulating solar panel of tens of KW power output.

Fig 5. CORTEX DC Programmable Power Supply is with SAS Function
As SAS power ratings increase through parallel operation of multiple rack-mounted units, the system transitions from a single-source behaviour to a distributed power architecture. At higher aggregated power levels, this introduces several engineering trade-offs:
While these effects may be negligible at low and medium power levels, they become increasingly relevant when emulating large solar arrays, where inverter control dynamics, grid interaction, and transient behavior are tightly coupled. In such cases, the limiting factor is no longer power capacity alone, but dynamic fidelity.
Once test scenarios extend into the hundreds-of-kilowatts and megawatt range, the dynamic demands on the test equipment increase significantly, with parameters such as slew rate and response bandwidth becoming critical. When power scaling is achieved through extensive parallelization of modular rack-mount units, these dynamic characteristics are often constrained by inter-module coordination and distributed control latency.

Fig 6. TITAN Series Solar Array Simulator by ActionPower
A cabinet-type solar array simulator, such as ActionPower’s TITAN Solar Array Simulator, delivers high power within a single chassis of architecture. Despite escalated footprint, it operates as one coherent electrical and control unit yet with higer power capability to achieve testing requirements without sacrificing dynamic performance when validating utility-scale and DER-level EUTs as per IEEE 1547.
The conclusion drawn from above compare and contrast is that the choice between rack-mount and cabinet-based SAS systems reflects a trade-off between flexibility and dynamic performance:
As reflected by these pros and cons, and their distinctions, system level behaviour incrementally outweighs component-level considerations along when power testing scales up from low to utility-scale ratings, representing the different concerns for validating discrete modules and large, grid-coupled energy assets with SAS power supplies.
As photovoltaic testing progresses from laboratory-scale validation to utility-scale array systems and DER-oriented applications, selecting the right simulation architecture becomes a system-level engineering decision.
ActionPower provides a complete portfolio of Solar Array Simulators and PV simulation solutions, covering panel-, string-, and array-level testing—from modular rack-mount platforms to integrated, high-power cabinet and tower systems.
Contact ActionPower to discuss your specific test requirements and explore how our full-scale SAS solutions can support accurate, high-dynamic, and standards-compliant photovoltaic system validation.

Zhiwei Bao holds 20+ patents in the field of mechanical engineering and is keen on industrial automation and product marketing. His interdisciplinary background, along with his passion and initiative for learning, has led him to a profound understanding of power electronics. He manages the technical copywriting for programmable power and testing topics at ActionPower through product-marketing-driven approaches.
About Zhiwei Bao
If you are looking for an automated test system to validate your products during development and research stages to make sure of their successful commercial launch, ACTIONPOWER will be at your disposal to study your specifications and requirements to provided either standard or customized testing solutions.
Specification-matching testing and simulation solutions need discussion of both parties. Actionpower welcomes you inquirt to study together with us about how we can automate your testing processes.
Send InquiryThese are the upcoming events and places you can find ACTIONPOWER and talk with us face-to-face!
Check EventsProfessionalism is what we care about. Why not email us with your technical requirements fully explained rather than submitting a simple message so that we revert more proactively with detailed solutions?