Home Contact EN

Blogs & Insights

Find out the latest innovations from ActionPower

Published on: Updated on: Author: Zhiwei Bao Reviewed: Sen Wang

What is a PV Simulator and How Can Reasearch and Development of PV Components Benefit from It?




The Age of Renewable Energy and Energy Generation Maximization

Being the prevailing trend the transformation towards renewable `and sustainable energy from generating by combustion of fossil fuel that consumes natural resources or by nuclear reaction which is seemingly safe yet implicate catastrophic result once accident happens, the research and development of more reliable devices like PV systems or wind turbines is being attached with further importance with industrial leaders taking the lead in the field.

Since a PV system operates based on the p-n junction effect to convert solar energy into electrical power, subsequently processed by devices such as power converters and inverters to feed into the energy storage system (ESS) or the grid, the system’s ability to maintain stable and reliable maximum power output depends largely on how well components like inverters interact with the upstream PV array and withstand grid anomalies such as voltage sags, swells, and other disturbances.

DC 3U PROGRAMMABLE BIDIRECTIONAL DC POWER SUPPLY

So what is that driving force behind the R&D towards meeting these requirements? Answering this question shortly it should be PV inverters, but we have more to discuss and cover within this blog:

  • Why PV Simulators are necessary for developing components for solar systems?
  • Both as devices for supplying and sourcing DC power, what are the differences between PV simulators and DC power supplies?
  • How does PV simulators work to simulate arrays of solar panel?
  • What are the solutions of ActionPower?

Why Do Researchers Need a PV Simulator?

PV simulators are devices to emulate the energy generation process of solar panels to offer dynamics DC power – to explain in a straightforward way.

photovoltaic industry

But a further detailed explanation should be based on the fact that PV components like inverters are supposed to interacts with dynamics situation of solar panels generating power under changing temperature and sun exposure, which is not practical to verify with a real and substantial array of solar panels and also for reason that nobody in the world can actively control how weather will be in the next minute.

Supposing a 100 kW photovoltaic system using high-efficiency 550 W monocrystalline PERC modules, it would require approximately 182 panels, each measuring about 2278 mm by 1134 mm (2.58 m²), resulting in a total module coverage area of around 470 m², excluding spacing for ventilation, maintenance, and optimal layout. This is evidently an unrealistic footprint to implement in a laboratory for testing inverters, disregarding the cost contingently.

The answer to this question then boils down simply to two facts:

  • Laboratory has limited space and cannot spend such huge money to implement a real solar system
  • Weather conditions and irradiance are uncontrollable

PV Simulator Works More Complexly and Proactively Compared to DC Power Supply

While both PV simulator and a standard DC power supply are sources of DC power, the former provides a more complex DC output and operates differently for reasons of specific emulation and testing needs.

DC Power Supply (Source) Operates in Auto-Ranging and CV, CC or CP mode

A standard DC power supply operating under CV and CC mode typically demonstrates a rectangular output characteristic.

Assuming a standard DC power supply with\(V_\text{RATED} \) of 500V and \(I_\text{RATED} \) of 120A, then maximum power of 60kW\(P_\text{MAX} \) by multiplying the former two specifications. The below chart demonstrates how such a DC power supply would operate in this rectangular characteristic within the limits defined by combinations of V*I as long as it is within the maximum power.

IV CURVE CC CV 60KW Voltage-current graph of a 500 V, 120 A, 60 kW DC power supply showing CV/CC output limits, with maximum voltage at 500 V, maximum current at 120 A, and marked operating points at 500 V 60 A for 30 kW and 500 V 120 A for 60 kW.

Standard DC Power Supply in CP output and Auto-Ranging Mode

Another situation less common compared to the rectangular characteristic of CC and CV operating model of a DC power supply, some models adopt a more flexible auto-ranging output characteristic that features a curved boundary when plotted on an I-V curve which is defined by the maximum rated power.

The below chart demonstrates a DC power supply with \(V_\text{RATED} \) of 500V and \(I_\text{RATED} \) of 120A, yet a maximum power of 15kW\(P_\text{MAX} \) instead of 60kW if these limits were fully utilized together, given the fact that that rated power is only 15kW.

As a result, the supply cannot deliver full voltage and full current simultaneously. Instead, it can provide any voltage–current combination within the 15 kW envelope from 125 V at 120 A on the low-voltage end to 500 V at 30 A on the high-voltage end. This operating range is reflected by the curved green line in the graph, which forms a hyperbolic constant power profile bounded by the maximum current and maximum voltage.

This type of auto-ranging design offers significant advantages in test environments where voltage and current requirements vary across use cases. It eliminates the need for multiple power supplies to cover different conditions, making it ideal for applications such as photovoltaic inverter simulation, battery testing, and power device characterization.

Voltage-current chart for a 15 kW autoranging DC power supply showing a constant-power curve bounded by 120 A maximum current and 500 V maximum voltage, with marked transition points near 125 V at 120 A and 500 V at 30 A.

PV Simulator’s Output is of More Complex and Controlled I-V Curve

Compared to a standard DC power supply, PV simulators generate more dynamically the I-V curves rather than simply following the ohm’s principle combining the rated power, voltage and current in a way of multiplication.

PV array I-V curve generated by a PV simulator, showing short-circuit current near 105 A, open-circuit voltage near 470 V, and the maximum power point at approximately 370 V and 89 A, with Vmp and Imp marked by dashed guide lines.

SAS Mode I-V Curve Example

The I-V curve generated in SAS (Solar Array Simulation) mode closely resembles the natural output characteristics of a real photovoltaic array, unlike rectangular or constant-power outputs seen in conventional DC power supplies.

In this configuration, current (A) is plotted on the Y-axis—a common convention in PV testing to highlight the behavior of the solar source under varying loads.

The entire curve is mathematically modeled by the simulator’s internal firmware based on just four key input parameters:

  • \(V_\text{_oc}\) (Open-Circuit Voltage): 475 V
  • \(I_\text{_sc}\) (Short-Circuit Current): 105 A
  • \(V_\text{_mp}\) (Voltage at Maximum Power Point): 375 V
  • \(I_\text{_mp}\) (Current at Maximum Power Point): 90 A

Once these four values are provided by the user, the simulator automatically generates a continuous I-V curve using its built-in algorithm. This makes SAS mode the most common and convenient method to simulate PV panel output under various conditions.

ActionPower PV simulator software interface showing photovoltaic I-V and P-V curves, with parameters including Voc 739.09 V, Isc 95.4 A, Vmp 630 V, Imp 90 A, and Pmp 56.7 kW, plus a programmable curve sequence list for PV simulation.

I-V Programming Mode of ActionPower SAS Software

Unlike SAS mode which auto-generates a curve based on four parameters, I-V Programming Mode allows engineers to manually define a fully customized I-V curve by defining with a table of a series of voltage and current combinations.

In this mode, the user defines a list of voltage–current (I-V) coordinate pairs, which the PV Simulator parses to reconstruct a complete I-V curve through interpolation. Unlike SAS mode, which follows a predefined mathematical model, I-V Programming Mode offers full flexibility. Engineers can simulate non-ideal or irregular PV behaviours such as ageing effects, partial shading, or module mismatch—by specifying custom curve profiles.

ActionPower’s PV Simulator supports up to 4096 V–I points, allowing engineers to generate extremely high-resolution, realistic I-V curves for advanced MPPT algorithm testing and fault condition simulation.

ActionPower PV simulator software in dynamic MPPT mode, displaying multiple I-V and P-V curves, photovoltaic parameters including Voc, Isc, Vmp, Imp and Pmp, and configurable MPPT ramp-test settings for changing irradiance and temperature conditions.
Static & Dynamic MPPT Tracking Mode of ActionPower SAS Software

Static MPPT (Maximum Power Point Tracking) Tracking refers to testing an inverter’s ability to locate and maintain operation at the maximum power point on a fixed, unchanging I-V curve. Dynamic MPPT Tracking, on the contrary, tests how well an inverter can follow the maximum power point in real time, as the I-V curve continuously changes to simulate fluctuating weather conditions.

Side-by-side screenshots of ActionPower PV simulator software comparing static and dynamic MPPT tracking, with I-V and P-V curves, PV parameters such as Voc, Isc, Vmp, Imp and Pmp, a static MPPT power-level matrix on the left, and multi-step ramp and timing settings for dynamic MPPT on the right.

ActionPower’s PV Emulation Power Supplies are Available with Different Design Features

ActionPower’s range of programmable DC power supplies and ATE systems are available as your options for testing PV components like solar inverters and hybrid ESS systems.

TITAN DC Programmable Power Supply is a tower-type high-power solar array simulator purposed for utility-scale power conversion system testing and validating their effectiveness as if connected to a real MW-level solar farm.

MW-Power PV Emulation Platform

CORTEX DC Programmable Power Supply is of rack-mount achitecture offering compact footprint for laboratory application where lower power is required for tens of kW testing scenarios, especially ideal for micro-inverter and other component level PV testing application.

Low Power (tens of kW) PV Simulator

 

 


ActionPower research and development team

Talk to ActionPower

From ActionPower we are open to listening to your suggestions and opinions.

For further media contact or consultation about any topics which might be of your interest about our company, you will be welcomed to send us an email to:

info@actionpowertest.com

Latest News


PRL DC Load Simulator Introduced by ActionPower for AI Server Workload Validation

Dynamics and power regeneration are no longer compromise to each other. Adopting innovation topology technologies is the PRL DC Load Simulator that accommodates ultra-fast dynamics, regenerative load and high-power scalability from a united single system.



ActionPower to Debut MIX Series Hybrid Power Supply at Europe Automotive Testing Expo 2025

The latest hybrid programmable power supply by ActionPower comes with 6 channels hybrid interface and allows AC/DC module arbitrary combination for flexible testing configuration where both AC and DC are...



CONTANCT US

Zhiwei Bao, SEO Engineer and technical copywriter at ActionPower
About the Author

Zhiwei Bao

Industrial Automation Power Electronics Product Marketing Field Application

Zhiwei Bao holds 20+ patents in the field of mechanical engineering and is keen on industrial automation and product marketing. His interdisciplinary background, along with his passion and initiative for learning, has led him to a profound understanding of power electronics. He manages the technical copywriting for programmable power and testing topics at ActionPower through product-marketing-driven approaches.

About Zhiwei Bao

Explore More

diesel generator and data center for AI facility

The Surge in AI data Center Construction is the Boom in Industrial...

Figures of Soaring AI Data Center Construction Following AI Boom Public available data shows the investment to data center construction...



Why Linear Loads Demonstrates Better Dynamics Performance than Regenerative Ones? And How ActionPower Breaks the Boundary?

Why Linear Loads Demonstrates Better Dynamics Performance than Regenerative Ones? And How...

Conventional testing applications where programmable electronic loads are deployed used to see a definite trade-off between dynamic performance and the...



combination of software and hardware is battery cycler's key feature

Grid Code Compliance Test Explained: What to Validate and Which Standards to...

Facing the modern grid landscape is the ever more important grid interconnection and interoperability, since DERs are now enacting as...




Get in Contact

Global Contact

Sales Network & Locations

If you are looking for an automated test system to validate your products during development and research stages to make sure of their successful commercial launch, ACTIONPOWER will be at your disposal to study your specifications and requirements to provided either standard or customized testing solutions.

Product Inquiry

Specification-matching testing and simulation solutions need discussion of both parties. Actionpower welcomes you inquirt to study together with us about how we can automate your testing processes.

Send Inquiry

Trade Shows & Events

These are the upcoming events and places you can find ACTIONPOWER and talk with us face-to-face!

Check Events

Social Media

Follow us to keep updated of our innovations.

LinkedInTwitter
Quick Model Access

Smart Discovery

Access our Power Supply Wizard to find the right programmable power supply for your use cases and testing scenarios.

discover programmable power supply by filtering with current, voltage and power ranges
CONTACT US

Contact Us

Professionalism is what we care about. Why not email us with your technical requirements fully explained rather than submitting a simple message so that we revert more proactively with detailed solutions?

Subscribe to Newsletter

Thank you for subscribing!