Home Contact EN

Blogs & Insights

Find out the latest innovations from ActionPower

Published on: Updated on: Author: Zhiwei Bao Reviewed: Sen Wang

What are the Differences between Inrush Current and Peak Current?




Powering up a device or equipment is not simply something as if pushing a button to turn it on. Something hidden and undiscovered during the very initial stage that last transiently at millisecond or microsecond scale can be a dramatic volatility that may even consequently, in extreme cases, break the device down. Such are the reasons, that all electronic circuits are supposed to be designed to withstand various ranges of odds that may occur during the operation to grant system durability and dependability.

The article outlines what is referred to as inrush current, especially in an AC power driven system, briefly talking about its causes, effects, subsequently extending the topics to its ambiguity with peak current and how do they matter for programmable AC power supplies.


What is Inrush Current and How it Occurs?

Inrush current is alternatively referred to as input surge current or switch-on surge [1]. Rather than the circuit’s rated current for steady state operation, the inrush current is defined as the maximum instantaneous input current that the electrical device draws when it is powered up [2], the value of which will exceedingly hit up to twenty or thirty times more than the nominal value the device operates with.

Fig 1. illustrates the transient occasion in form of current waveform when a device is turned on as an example of inrush current. The initial start-up current value soars suddenly up to a peak current of 3.6 A in a very short time span and then falls back to the device’s nominal operation current, or steady state current for the circuit, of 0.3 A or 300mA. The diagram is arranged with time axis valued by ms and yet can be in microseconds as well.

Line graph plotting Current in amperes versus Time in milliseconds. The curve demonstrates a sudden initial surge, rising to a labeled 'Peak Current' of 3.6A, before dropping and leveling off at a 'Steady State Current' of 0.3A. A vertical arrow labeled 'Inrush Current' highlights the 3.3A difference between the steady state and the peak.
Fig 1. Inrush Current, Peak Current, Steady State Current – Credit: ActionPower

Why Does Inrush Current Occur in the Circuit?

Supposing you are trapped in a traffic jam driving your Mercedes E-class Sedan and frequently stumble across traffic lights that each 1 kilometre which will hold you up for 60 seconds. With some quick glimpse on the vehicle interface where real-time fuel consumption is indicated, you may soon find out that your Benz consumes extremely much more fuel within the short time span during startup than in steady running speed, probably 40L per 100km compared to 11L per 100km respectively. Higher energy is always a must to pull the car head, but it becomes more economic when car moves at faster speed.

startup fuel consumption of car - Illustration comparing fuel consumption of an E-Class sedan during acceleration from startup to 60 km/h and while cruising at a constant 60 km/h, showing higher fuel use during acceleration.
Fig 2. How Much Fuel Does Your E-Class Sedan Burns From Startup to Constant Speed? – Credit: ActionPower

This the same pattern which happens to a circuit, where capacitors, inductors, chokes, and transformers are present that draw huge initial current to develop electric and magnetic field for initiating the device’s operation. Respective, the circuit grants a sudden low resistance or impedance path that allows large current value to flock into the circuit.

Ambiguity between Peak Current and Inrush Current

While technically the terminology of “peak current” can actually apply to both inrush current and steady-state current, it does not suggest that peak current and inrush current are the same phenomenon. Actually, however, the maximum instantaneous current at any point in time is called the peak current, regardless of whether it occurs during inrush or steady-state operation.

crest factor peak rms value of current - Sine-wave diagram comparing peak and RMS current levels, illustrating crest factor as the ratio of peak value to RMS value.
Fig 3. Peak and RMS Value of Single Phase Current – Credit: ActionPower

The blow instances clarify the subtle distinction here:

  • During inrush, the waveform can have a very large transient spike – the peak inrush current, which may be several times higher than normal operation.
  • During steady-state, the current still varies sinusoidally (for AC loads), so it also has a peak value every cycle, but this value is stable and proportional to the RMS current by a known factor, or say, crest factor. For example, \( I_\text{peak} = 2\times I_\text{RMS} \) for a pure sine wave.

Or in other words,

  • Every waveform has a peak.
  • Only startup events have an inrush current.
  • The inrush peak is often much higher than the steady-state peak, which is why engineers must check both when specifying power supplies, fuses, or current-limiting circuits.

Explore ActionPower’s RMS Voltage Calculator to calculate your AC voltage supply

Why and How Does it Matter for Programmable AC Power Supply?

Distinguishing the subtle difference and clarifying the ambivalence which arise from when people interpret “peak current” as referring only to steady-state operation, ignoring that inrush events also have their own (often much higher) peaks. Though it would be something rarely happens and a lack of professionalism, engineers must clarify whether the peak current limit refers to normal operation or to transient inrush handling, because that determines whether the source can safely supply startup surges without tripping or current limiting.

To take one step further, understanding the inrush current properly helps to select the right programmable power supply for power testing application. The over-specification when selecting a programmable power supply with only purposes and intents to cover the transient peak inrush current, which is usually several times higher that the required testing current, will eventually translate into deploying a system with specifications that are much higher than the actually required ratings. It also results in higher cost, larger footprint, and greater energy consumption. Understanding inrush profiles allows engineers to choose a supply with appropriate short-term overload capability or surge rating, rather than an unnecessarily high continuous rating.

Bibliography

  • [1] Inrush current, From Wikipedia, the free encyclopedia, Link
  • [2] Inrush Current – Causes, Effects, Protection Circuits and Design Techniques, November 27, 2019, Sourav Gupta, Circuit Digest, Link
  • [3] Understanding power supplies and inrush current, Bear Power Supplies, Technical Note, Link

 

 


ActionPower research and development team

Talk to ActionPower

From ActionPower we are open to listening to your suggestions and opinions.

For further media contact or consultation about any topics which might be of your interest about our company, you will be welcomed to send us an email to:

info@actionpowertest.com

Latest News


PRL DC Load Simulator Introduced by ActionPower for AI Server Workload Validation

Dynamics and power regeneration are no longer compromise to each other. Adopting innovation topology technologies is the PRL DC Load Simulator that accommodates ultra-fast dynamics, regenerative load and high-power scalability from a united single system.



ActionPower to Debut MIX Series Hybrid Power Supply at Europe Automotive Testing Expo 2025

The latest hybrid programmable power supply by ActionPower comes with 6 channels hybrid interface and allows AC/DC module arbitrary combination for flexible testing configuration where both AC and DC are...



CONTANCT US

Zhiwei Bao, SEO Engineer and technical copywriter at ActionPower
About the Author

Zhiwei Bao

Industrial Automation Power Electronics Product Marketing Field Application

Zhiwei Bao holds 20+ patents in the field of mechanical engineering and is keen on industrial automation and product marketing. His interdisciplinary background, along with his passion and initiative for learning, has led him to a profound understanding of power electronics. He manages the technical copywriting for programmable power and testing topics at ActionPower through product-marketing-driven approaches.

About Zhiwei Bao

Explore More

diesel generator and data center for AI facility

The Surge in AI data Center Construction is the Boom in Industrial...

Figures of Soaring AI Data Center Construction Following AI Boom Public available data shows the investment to data center construction...



Why Linear Loads Demonstrates Better Dynamics Performance than Regenerative Ones? And How ActionPower Breaks the Boundary?

Why Linear Loads Demonstrates Better Dynamics Performance than Regenerative Ones? And How...

Conventional testing applications where programmable electronic loads are deployed used to see a definite trade-off between dynamic performance and the...



combination of software and hardware is battery cycler's key feature

Grid Code Compliance Test Explained: What to Validate and Which Standards to...

Facing the modern grid landscape is the ever more important grid interconnection and interoperability, since DERs are now enacting as...




Get in Contact

Global Contact

Sales Network & Locations

If you are looking for an automated test system to validate your products during development and research stages to make sure of their successful commercial launch, ACTIONPOWER will be at your disposal to study your specifications and requirements to provided either standard or customized testing solutions.

Product Inquiry

Specification-matching testing and simulation solutions need discussion of both parties. Actionpower welcomes you inquirt to study together with us about how we can automate your testing processes.

Send Inquiry

Trade Shows & Events

These are the upcoming events and places you can find ACTIONPOWER and talk with us face-to-face!

Check Events

Social Media

Follow us to keep updated of our innovations.

LinkedInTwitter
Quick Model Access

Smart Discovery

Access our Power Supply Wizard to find the right programmable power supply for your use cases and testing scenarios.

discover programmable power supply by filtering with current, voltage and power ranges
CONTACT US

Contact Us

Professionalism is what we care about. Why not email us with your technical requirements fully explained rather than submitting a simple message so that we revert more proactively with detailed solutions?

Subscribe to Newsletter

Thank you for subscribing!