Find out the latest innovations from ActionPower
Testing instruments and equipment have been evolving continuously thanks to the advancement of power electronics and power semiconductors, from which now the design and development of new testing devices are benefiting considerably to achieve better efficiency and effectiveness.
In the case of programmable power supplies purposed for testing and validation, functions and programmability, as well as their versatility are getting increasingly powerful in a single enclosure. Bidirectional power supplies as one of the latest innovations stands for an iconic step forward of these advancements.

The technical article presented studies the technical features and testing applications of bidirectional DC power supplies and then analyses their advantages in relation to some actual use cases. Most of ActionPower’s latest design of programmable power supplies are with bidirectional testing capability to streamline your power test validation and save energy cost with regenerative load functionality – not simply additionally working as electronic load.
Supposing that you are a laboratory engineer who is developing a new prototype of servo motor and you are about to verify and log its performance. A normal power supply would serve this application by converting your local utility grid power into a DC output to drive the motor. However, if regenerative power from the motor is generated, such kind of conventional and normal power supply is not capable of absorbing the latter.

Fig 1. A normal power supply cannot absorb regenerated power from the motor
The conventional approach to this case, where regenerative power is generated from the motor, is to implement an additional set of electronic load to absorb the power. Yet those outcomes that come along with this solution, to some extent, can be counterproductive from other perspectives.

Fig 2. Power supply may combined with an electronic load to test motor
Deploying an additional set of equipment means more cost of asset procurement, along with equipment management cost and ownership cost that will constantly run up in the long-run including those risen from maintenance as well as those incurred by wiring and auxiliary devices like multimeter and oscilloscope.
One additional set of equipment means less space in the laboratory. While both the power source and electronic load serve for the same testing applications, the laboratory sees a decreased productivity per area, now that the space used for deploying the additional electronic loads could have been taken available for other testing purposes.
One of the key concerns that overrides all the others is that an electronic load dissipates all the absorbed power into heat, supporting which features it must be combined further with additionally forced cooling devices. Implementing an additional electronic load leads to further heat management issues.

Fig 3. Bidirectional Power Supply Integrates Source and Load in a Single Enclosure
A bidirectional DC power supply is typically installed between the device under test that features as well bidirectional power flow and on another bus of the EUT the testing devices can either be a bidirectional DC power supply or an AC programmable power. The setup should be couped with miscellaneous measurement and power analysing instruments.
The below testing topology where bidirectional onboard charger is validated EUT serves as an example for your better understanding.

Fig 4. Test Setup for a Bidirectional Onboard Charger Featuring the CORTEX DC Bidirectional Power Supply
| Item | Example Selection / Parameter |
|---|---|
| DUT | 30 kW bidirectional isolated DC/DC converter |
| HV Port | 800 V nominal battery side |
| LV Port | 400 V nominal DC bus side |
| Power Flow | Bidirectional, buck and boost operation |
| HV-Side Power Supply | CORTEX bidirectional DC power supply, 1000 V / 80 A / 30 kW class |
| LV-Side Power Supply | CORTEX bidirectional DC power supply, 500 V or 600 V / 30 kW class |
| Measurement | Power analyzer, oscilloscope, HV differential probes, current probes |
| Communication | CAN, RS485, Ethernet, or analog I/O depending on DUT interface |
| Safety | Contactor, fuse, pre-charge circuit, E-stop, insulation monitor |
| Test Modes | CV, CC, CP, battery simulation, source/sink transition |
| Key Data | Voltage, current, power, efficiency, ripple, overshoot, response time, fault status |
In this setup, two CORTEX bidirectional DC power supplies are connected to both DC ports of the DC/DC converter. The HV-side unit emulates an 800 V battery pack, while the LV-side unit emulates a 400 V DC bus or regenerative load.
During buck-mode testing, power flows from the HV battery simulator through the DC/DC converter to the LV DC bus simulator. During boost-mode testing, the direction is reversed, and power flows from the LV side back to the HV side. Since both power supplies support source and sink operation, the same wiring can validate forward power flow, reverse power flow, charge/discharge transition, and regenerative loading without reconnecting the test bench.
A power analyzer and oscilloscope are connected across both DC ports to record voltage, current, power, efficiency, ripple, and transient response. The control host communicates with the power supplies and DUT through CAN, RS485, Ethernet, or analog I/O, allowing automated test sequences such as startup, load step, mode transition, battery profile simulation, and fault protection validation.
A bidirectional power supply can act as a battery simulator like TITAN Series Power Supply by shaping its output to mimic a cell’s terminal behaviour instead of holding a perfectly stiff voltage.
Bidirectional power supply is programmable for a certain open-circuit-voltage (OCV) vs. state-of-charge (SOC) curve and an internal resistance (Rint) so that the terminal voltage naturally sags under discharge or rises during charging process as if a real world battery. Engineers can take advantages of the programming flexibility to set different OCV and Rint to emulate either a fresh battery pack with ¨low resistance or an high-resistance battery pack suffered from ageing (permanent degradation) or cold temperature conditions (temporary and reversible degradation).

Fig 4. Exemplar SOC-OCV Curve at Varied Temperature Conditions – Credit: CALCE-UMD [1]
| Aspect | Traditional (Power Supply + Electronic Load) | Bidirectional Power Supply |
|---|---|---|
| Energy Handling | Dissipates energy as heat (unless using a separate regenerative load). | Regenerates energy back to grid or internal bus; minimal heat. |
| Efficiency & HVAC | Lower efficiency; high heat → larger cooling/HVAC needs. | Higher efficiency; reduced thermal load and cooling costs. |
| Equipment Count & Footprint | Two instruments + switching/relays; larger footprint. | Single instrument replaces source + load; smaller footprint. |
| Wiring & Changeover | Complex cabling; manual/relay switching between source ↔ sink. | Seamless four-quadrant operation; no external switching. |
| Test Coverage | Good for steady sourcing or sinking; limited seamless bidirectional profiles. | Full four-quadrant profiles (CC/CV/CP/CR, regen braking, V2X, etc.). |
| Total Cost of Ownership | Lower purchase price per box, but higher energy and HVAC, more maintenance and calibration. | Higher upfront cost, lower operating cost; fewer calibrations and less downtime. |
ActionPower keeps abreast of the technical advancement by empowering our ranges of programmable power supplies and ATE system with those latest technologies including bidirectional power-flow and regenerative load technologies apart from multi-channel architecture. To discover how our bidirectional power supplies may serve your different testing applications and projects, visit our pages of bidirectional power supplies or get in contact with our sales team for further support.
Bidirectional bench DC power supply PRD features high power density at 3U size with rack option to scale up to 3MW, with further advantages of regenerative load and load emulation capability.


Zhiwei Bao holds 20+ patents in the field of mechanical engineering and is keen on industrial automation and product marketing. His interdisciplinary background, along with his passion and initiative for learning, has led him to a profound understanding of power electronics. He manages the technical copywriting for programmable power and testing topics at ActionPower through product-marketing-driven approaches.
About Zhiwei Bao
If you are looking for an automated test system to validate your products during development and research stages to make sure of their successful commercial launch, ACTIONPOWER will be at your disposal to study your specifications and requirements to provided either standard or customized testing solutions.
Specification-matching testing and simulation solutions need discussion of both parties. Actionpower welcomes you inquirt to study together with us about how we can automate your testing processes.
Send InquiryThese are the upcoming events and places you can find ACTIONPOWER and talk with us face-to-face!
Check EventsProfessionalism is what we care about. Why not email us with your technical requirements fully explained rather than submitting a simple message so that we revert more proactively with detailed solutions?