Solar Emulation and Inverter Testing: Introduction and Guide to ActionPower’s PV Simulator DC Power Supplies

The present session of application note focuses of the specific programmable and emulation funtions of testing power supply for, not simply providing a DC source, but to dynamics emulate it in a non-linear form to simulate the I-V pattern of energy generated from a real-world photovoltaic component such as a PV array.

Following a detailed technical explanation to how these programmable DC sources emulate solar energy generation process's electrical behavious, a further user guide will be provided with regard to what ActionPower offers and how to select the right testing power source for correspongding applications. This note will support Inverter R&D, lab testing engineers, certification labs, grid compliance teams to learn about why programmable power matters for this specific testing application.

Version1.0.0
Categories PV Testing
Download Download Application Note
Download Count 8
Page Views 2973
Size 696.06 KB
Create Date04/02/2026
Last Updated04/11/2026
AuthorZhiwei Bao
ReviewedSen Wang

Breakdown of Operation: Real-world PV Array Connected to an Inverter for Generating Solar Energy

Either large-scale DERs or micro-grids, for example, within a sustainable facility of a manufacturing company further integrated with an energy storage system (ESS), would operate dynamically with a coupled power electronic system where PV arrays and inverters continuously influence each other. One fact to underline is that – such a grid-connected photovoltaic system is not simply “solar panels plus an inverter” yet faces both factors both within its system and from external conditions that affect their operating patterns and behaviour.

Understanding this interaction is essential before discussing why laboratory testing must rely on PV emulation rather than real panels. At a high level, a typical utility-scale or distributed PV system with energy storage can be understood as three tightly linked stages:

  • Energy capture: Solar energy is converted into DC power by the PV array and regulated through a DC/DC converter with MPPT before being delivered to a common DC bus.
  • Energy buffering: A battery energy storage system (BESS) is connected to the same DC bus via a bidirectional DC/DC converter, allowing the system to store excess energy or supply power when needed.
  • Grid interfacing: A grid-connected DC/AC inverter converts the DC-bus power into AC and delivers it to the utility grid through a filter and coupling transformer at the point of common coupling (PCC).

PV array and inverter circuit connected to grid and integrated with BESS

Displyed as above is an abstracted system topology for demonstrating their relations. Note that each of the components and sections engaged here is not an independent block. Nevertheless, they operate as a closed-loop system whose operating point is determined jointly by sunlight conditions, PV physics, and inverter control algorithms.

A System-Level Overview: From Power Flow from DC to Inverted AC Power for Grid

At the beginning end of the topology, DC power generated by the PV array is in nature environment-dependent and of non-linear characteristics that cannot be used directly for downstream loads or feeding to loca AC grid. The inverter thus behaves as a controllable electronic load from the PV side to convert the DC source for supplying grid side. Generally the processes follow below sequence, where the part of BESS is neglected:

  • Solar irradiance → PV array current and voltage: Solar irradiance is converted into DC voltage and current by the PV array according to its nonlinear I–V curve. Higher irradiance mainly increases current, while higher cell temperature mainly reduces voltage.
  • PV array → DC link of the inverter: The DC/DC stage delivers conditioned power from the PV array to the inverter’s DC link. The inverter actively regulates the DC-link voltage and adjusts how much current it draws from the PV array based on its control strategy (e.g., MPPT).
  • Inverter’s AC link → AC grid: The inverter synthesizes sinusoidal AC current and injects controlled active and reactive power into the grid while complying with voltage, frequency, and power-quality requirements.

Understanding PV Array Characteristics: The Prerequisite to Conducting Inverter Testing

While the topic of this application note is about testing inverters, when we are proceeding with the technical introduction what we cover primarily will be about solar emulation – which seems to be confusing if you are new to this application field. In order to avoid such a confusion, the below introductions should pave the theoretical foundations to understanding why use solar emulation for testing PV inverters.

testing scenario with regenerative grid simulator by actionpower

Non-stable Electrical Behaviours due to External Factors

That the DC power generation process from PV array is non-stable ascribes to solar cell’s non-linear electrical nature [1] and sensitiveness to environment conditions.

A solar cell is a light-controlled non-linear current source whose output current fundamentally relies on incident irradiance, meanwhile that the output voltage depends on its internal PN junction characteristics and the operating load condition. Therefore, whenever irradiance or temperature changes, the number of photogenerated carriers, the junction voltage, and the equivalent internal impedance vary simultaneously, causing the entire I–V curve to shift.

All of these unstable characteristics resulst in continuous fluctuations in voltage, current, and available power, rather than maintaining a constant output like an ideal power source.

pv simulation an array of solar panels

Physical Characteristics of a PV Module (Electrical View)

To review its non-stability further from an electro-physical perspective, a photovoltaic array (or more exactly a single module) can be understood as a nonlinear source coupled with an internal impedance network that varies with irradiance and temperature, which defines its fundamental electrical “behaviour”:

  • Short-Circuit Current \(I_\text{SC}\): primarily determined by irradiance. Higher irradiance generates more photocarriers, causing \(I_\text{SC}\)​ to increase almost linearly; when shading or clouds occur, the current drops instantaneously—this is one of the root causes of rapid PV power fluctuations.
  • Open-Circuit Voltage \(V_\text{OC}\): mainly influenced by temperature (take specifically note that here the temperature refers to the solar cell’s own temperature of \(T_C\)). As temperature rises, the reverse saturation current of the PN junction increases, leading to a decrease in \(V_\text{OC}\)​; when temperature drops, \(V_\text{OC}\)​ increases – this explains why cold and sunny conditions can yield higher voltages.
  • Equivalent impedance (operating impedance): PV module does not have a fixed internal resistance; its equivalent impedance varies with the operating point, with behaviour resembles a curved impedance characteristic rather than a constant resistor. (large impedance around open circuit, low impedance near the short circuit.)
  • Maximum Power Point (MPP): solar module is externally continuously tracked by its load or inverter to maintain the operating point around a specific MMPT of \(  (V_\text{MPP},I_\text{MPP}) \) where the product of voltage and current is maximum.

Therefore, a PV module is neither an ideal current source nor an ideal voltage source, but rather an environment-driven nonlinear source – its current is governed by light intensity, its voltage is determined by temperature and load conditions, and its equivalent impedance drifts with the operating point. Together, these physical characteristics give rise to its inherent variability.

Why Testing Inverters is all Fundamentally about PV Emulation?

Let’s start with a questions. What is the purpose and what factors are to be tested we say “inverter testing”?

In practice, inverters are hardly tested as isolated devices in real validation scenarios. Yet instead, we need to test how the inverter behaves when coupled with a realistic PV source under changing environmental and grid conditions [2]. Therefore, the core of inverter testing is not only about power conversion efficiency or control stability, it is fundamentally about how the inverter interacts with a dynamic, nonlinear PV input. And just like all scientific experiments may suggest, what we need for such kind of testing are definitely variables which are controlled, dependent or independent.

Then we have a second question to ask: How it happens if we handle this testing application with a real solar module while ensuring controlled variables given the fact that they are non-stable (as what we explained in the previous chapter)?

\[
\fbox{What are we really testing?}
\;\Rightarrow\;
\fbox{Inverter + realistic PV interaction}
\;\Rightarrow\;
\fbox{PV and inverter are dynamically coupled}
\;\Rightarrow\;
\fbox{Real panels are not controllable in lab}
\;\Rightarrow\;
\fbox{Use programmable PV emulation}
\]

This shift in perspective leads directly to the conclusion that meaningful inverter validation requires accurate PV emulation, rather than relying on real panels, nor a generic DC supplies. But regarding this conclusion we have more questions to ask.

What Factors Exactly Have to be Simulated in Lab Testing for Inverter?

Laboratory testing scenario requires the right variables to be simulated in a controlled, repeatable, and programmable way. Obviously, what is needed there is not “real-wold sunlight”. Fundamentally and in practice, categories of factors must be faithfully emulated in the lab:

Factor to be simulatedWhat must be reproduced in the labWhy this matters for inverter testing
Environmental variability of the PV sourceTime-varying irradiance profiles and temperature effects on the PV arrayField conditions are continuously changing; static DC inputs cannot represent real operating behaviour
Nonlinear PV I–V characteristicThe curved I–V relationship and a well-defined Maximum Power Point (MPP)A real PV array is not an ideal voltage source; realistic source behaviour is required for valid results
Dynamic interaction between PV and inverter (MPPT loop)Closed-loop interaction where the inverter perturbs voltage and tracks the MPPFixed-voltage DC sources break the feedback loop that defines real inverter operation
Extreme and fault scenario injectionPartial shading, abrupt power dropouts, rapid irradiance ramps, and unstable operating pointsThese corner cases are unsafe or impractical outdoors but critical for design validation

Why a Generic DC Power Supply is not Sufficient for PV Emulation and Inverter Testing?

A common programmable DC power supply, though seems to be sufficiently functional for most DC-side testing application like for power semiconductors and electric components, it is not capable of approximate dynamically the I-V behaviours of PV modules, however, due to the more complex coupled logics and variables. ActionPower once explained the differences between a DC power supply and a PV simulator, you may find detailed explanation by reading this article.

To put it briefly, and according to the testing needs in laboratory scenario discussed above, a generic programmable DC power supply lacks the following functions for matching inverter testing:

  • Not equivalent to a real PV source: a conventional DC supply behaves as an ideal voltage source rather than a nonlinear photovoltaic array.
  • Lacks realistic I–V dynamics: it cannot reproduce the curved I–V characteristic, MPP behaviour, or environmental variations.
  • Breaks closed-loop MPPT interaction: a fixed-voltage source prevents meaningful perturb-and-observe or adaptive MPPT behaviour.
  • Lacks PV-situation matching fault production functions: a conventional DC source only regulates current, voltage and power. It is not able to reproduce PV module faults.

Hardware Foundation of Solar Emulation: Technical Introduction to PV Simulators

A PV simulator is a programmable DC source capable of reproducing realistic PV I–V characteristics under dynamic conditions, and of course, to address the above discussed testing and emulation functions essential for laboratory scenario when validating inverters – review again the previous chapter if necessary.

Shortly, from a hardware perspective, PV simulation can be viewed as a control problem executed by power electronics: the power stage must respond quickly and predictably so that the intended PV model (I–V curve, MPP movement, irradiance/temperature dynamics) is expressed at the terminals seen by the inverter. The following context will explain which are the key capabilities and specifications that matter for PV simulators.

Fast and Predictable Voltage/Current Dynamics (Slew and Bandwidth)

Real scenario of solar energy generation has its MPPT dynamically following real and abrupt change of irradiance and cloud-edge effects which represents, in the case of in-lab simulation with a power source, the capability of fast change to let terminal voltage and current move at a realistic rate along the I–V curve is a must for realistic emulation.

In practice, the inverter continuously perturbs its DC operating point during MPPT, and real irradiance can change abruptly due to cloud transients. The PV simulator must therefore be fast enough to let the terminal voltage and current move at a realistic rate along the I–V curve. Further advantages are with transient behaviours such as start-up, curtailment, ride-through recovery which should be trustworthy.

Low Output Capacitance and Limited Electrical Interaction with the Inverter

For meaningful PV emulation, the simulator should minimize parasitic electrical interaction with the inverter while still maintaining stability. Lower effective output capacitance reduces unwanted circulating currents during fast operating-point changes and prevents the test source from behaving like an artificial energy buffer that real PV arrays do not possess. When this balance is achieved, the inverter “sees” a source that behaves more like a solar array and less like a stiff laboratory capacitor bank.

Scalable Power through Reliable Parallel Operation

Real-world PV systems from a lower power array for household use until megawatt utility scale solar array systems have distinct systems for power conversion and grid connection. Thus the PV simulator used correspondingly for their inverter testing should be able to cover a range of power ratings. See our past article where we discussed the pros and cons of modular rackmount units and cabinet system when upscaling for high power testing application.

The system should further be able to maintain its electrical performance when more and more units are getting parallelled through master-slave connection. ActionPower’s typical cabinet and tower type systems are independent IGBT-based, while offering high power per unit, minimizing the system degradation in communication and responses compared to modular rackmount units [3].

Essential Software Functions and Programming Options for Solar Emulation and Inverter Testing

Hardwares lays down the foundation for operation performance and system specifications for PV simulators as power sources, however, it is by the software that the system is enhanced with the capability to how hardware behaves over time during automation and testing sequence. That is to say, the software layer that decides what kind of “PV array” the inverter actually sees at its terminals and how that virtual array evolves under changing conditions.

ActionPower’s PV emulation software of Action 2020 is built around the blow complementary modelling approaches and a high-resolution execution engine. Test engineers can enjoy its advantages to choose the right level of abstraction, from physics-based modelling to pure data-driven curves, while preserving dynamic fidelity and repeatability.

Physics-Based Reference Modelling

ActionPower software supports generation of I–V curves from reference cell and array parameters aligned with recognized standards such as EN50530 and Sandia-style formulations. Instead of manually drawing curves, users can define a small set of physically meaningful inputs, such as reference temperature and irradiance, the key operating points \(\,V_{oc}, I_{sc}, V_{mp}, I_{mp}\,\), and technology-dependent coefficients \(\alpha\) and \(\beta\).

Physics-based reference modeling with ActionPower software for PV emulation

Based on these inputs, the software automatically constructs a full, smooth I–V characteristic that reflects PV behaviour and scales consistently with temperature and irradiance. Built-in material presets (e.g., c-Si or thin-film) can pre-populate key coefficients in accordance with the selected standard, reducing setup time while maintaining traceability.

Simplified Parameter Modelling

For rapid setup, the software can generate a realistic curve using a minimal parameter set, typically the open-circuit voltage \(\,V_{oc}\), short-circuit current \(\,I_{sc}\), and the Maximum Power Point \(\,(V_{mp}, I_{mp})\). From these four values, the tool reconstructs an I–V envelope with proper curvature and a well-defined MPP region.

Data-Driven Custom Curves (High-Resolution Manual or CSV Import)

When measured module data are available, ActionPower software accepts fully custom I–V definitions via manual entry or CSV import. TITAN Solar Array Simulator with PV emulation software executes curves with up to 4096 points, enabling near-continuous representation of complex shapes, such as multi-knee behaviour caused by partial shading or string mismatch. During operation, the simulator performs piecewise linear interpolation between adjacent points to preserve fidelity while keeping transitions smooth.

Static MPPT Curve Interface Manual Mode Interface Diagram

Dynamic Scenario Execution and Automation Integration

Beyond static curves, irradiance, and temperature can be treated as time-varying inputs rather than fixed values. Users may define dynamic profiles—such as ramps, steps, oscillations, or recorded weather traces—and the simulator continuously reshapes the I–V curve in real time. A built-in interpolation mechanism ensures smooth transitions between operating conditions, avoiding artificial discontinuities that could otherwise mislead inverter control.

MPPT emulation I-V curve sequence automation with PV simulator     shadow sunlight irradiance automation PV emulation software of actionpower

Complete PV scenarios can be assembled as ordered sequences of curves and time segments with programmable rise time, hold time, and trigger conditions. These sequences can be executed from a host PC or stored internally for stand-alone operation, enabling long-duration burn-in tests and repeatable certification workflows without continuous external supervision.

At the same time, ActionPower software exposes open, programmable interfaces (e.g., SCPI over LAN, with optional field bus support depending on configuration), allowing integration with automation environments such as LabView or Python. Engineers can generate curves programmatically, synchronize PV profiles with other bench instruments, and log \(\,V\), \(\,I\), and \(\,P\) trends over time for closed-loop validation.

ActionPower’s Range of Hardwares and Programmable Power for Solar Emulation

Following our detailed explanations to key functions and capabilities of hardware and software that matter for inverter testing. This section helps you match ActionPower’s hardware platforms to your specific photovoltaic inverter testing needs ranging from component-level R&D to MW-scale validation. We organize this guide by typical test scenarios and required capabilities so you can select the appropriate test platform with confidence.

CORTEX DC Programmable Power Supply: Component and Development-Level PV Testing

ActionPower’s programmable DC supplies offer high precision, bidirectional control and fast dynamic response suitable for emulating PV behaviour in small to moderate power ranges. The rack-mount CORTEX DC platform provides low-ripple output, fine voltage/current resolution, and fast transient performance that supports realistic I–V emulation for MPPT tuning, start-up sequencing, and closed-loop inverter validation. The modular 3U design enables easy bench integration and scalable expansion in standard racks.

A programmable DC source tailored for tens-of-kilowatts string inverter and power conversion testing, supporting realistic PV source emulation, multi-MPPT behaviour verification, efficiency mapping, and stable long-duration operation under representative operating conditions.

Modular Rack-Mount PV Simulator

 

TITAN Solar Array Simulator: String Inverter and High-Power PV Validation

TITAN Solar Array Simulator is a scalable, high-fidelity PV emulator designed for both string-level R&D and utility-scale inverter validation. It delivers realistic, high-resolution I–V behaviour (up to 4096 points), supports EN50530/Sandia dynamic profiles, and can be expanded in parallel from hundreds of kilowatts to multi-megawatts.

High-power cabinet/tower type system specifically designed for utility-scale power conversion system connected to grid and BESS. Future-proof capability of 2000VDC and 10MW power capability for advanced photovoltaic system-level research and development

2000VDC & 10MW Utility-Scale PV System Simulator

 

HELION Programmable Power Supply: Modular & Multi-Channel Testing for PV Arrays and Multi-EUT Setups

The HELION multi-channel modular power supply features plug-and-play AC and DC modules in a compact footprint, allowing arbitrary combinations of power channels for hybrid power testing. PV emulation modules within the HELION system can be combined with other AC/DC modules to support complex test topologies. More detailed introduction to how Helion can test multiple EUTs of micro-inverters can be found by this application note.

Hybrid AC DC architecture with 6 module-based slots for multi-channel and power-flow loop setup. Ideal for micro-inverter testing through PV emulation module output and AC load module combination which allows simultaneous testing of three inverter units.

PV Simulator for Micro-Inverter Testing

Wrap-Up

Rigorous photovoltaic inverter validation requires testing the inverter–PV system as an integrated dynamic loop, not the inverter in isolation. Because real PV arrays are nonlinear, environment-dependent, and non-repeatable in laboratory settings, while conventional DC supplies behave as near-ideal voltage sources, neither approach can adequately represent the true operating conditions that shape MPPT behaviour, transient stability, and grid-interaction performance. High-fidelity PV emulation that combines fast, bidirectional, stable DC source with model-driven, time-varying I–V software is therefore essential for producing results that are both repeatable in the lab and representative of field behaviour.

ActionPower’s programmable powers, from compact rack-mount CORTEX DC power supply to scalable TITAN Solar Array Simulators and modular multi-channel solutions, are designed around this system-level philosophy: realistic source physics, dynamic fidelity, automation readiness, and scalable power. Whether you are validating MPPT algorithms, executing EN50530/Sandia workflows, or testing MW-class central inverters, ActionPower provides configurable hardware and software that grow with your test needs. To design your optimal PV emulation setup or request a demonstration, contact ActionPower’s applications team to build a test architecture tailored to your program.

Bibliography

  • [1] Asada, S., Shinokita, K., Watanabe, K. et al. Nonlinear photovoltaic effects in monolayer semiconductor and layered magnetic material hetero-interface with P- and T-symmetry broken system. Nat Commun 16, 4827 (2025). Link
  • [2] Understanding PV System Standards, Ratings, and Test Conditions, Feb 14, 2024 by Ahmed Sheikh, EE Power, Link
  • [3] Solar Emulation and Inverter Testing, Magna-Power, Link

 


Zhiwei Bao 鲍智威, with Wikidadata entry www.wikidata.org/wiki/Q141170017, is an SEO Engineer at ActionPower, Technical Copywriter for Power Electronics and Grid Compliance | Zhiwei Bao is also owner of ÉLITER Packaging Machinery, as mechanical engineer and inventor, holding more than 20 patents
About the Author

Zhiwei Bao

Industrial Automation Power Electronics Product Marketing Field Application

Zhiwei Bao holds 20+ patents in the field of mechanical engineering and is keen on industrial automation and product marketing. His interdisciplinary background, along with his passion and initiative for learning, has led him to a profound understanding of power electronics. He manages the technical copywriting for programmable power and testing topics at ActionPower through product-marketing-driven approaches.

About Zhiwei Bao
Quick Model Access

Smart Discovery

Access our Power Supply Wizard to find the right programmable power supply for your use cases and testing scenarios.

discover programmable power supply by filtering with current, voltage and power ranges
CONTACT US

Contact Us

Professionalism is what we care about. Why not email us with your technical requirements fully explained rather than submitting a simple message so that we revert more proactively with detailed solutions?

Subscribe to Newsletter

Thank you for subscribing!